All material © 2010 Martin Audio Ltd. Subject to change without notice
39
7.2
Thermal Dissipation
Martin Audio MA18K & MA18KDSP
Level
Load
Rated
Power
AC Mains
Watt
Thermal Dissipation
230V AC 115V AC
Out
In
Dissipated BTU/hr
Kcal/hr
Switch off or remote power off by software*
0.86
0.52
0
2.95
2.95
10
2.5
Power on, amplifier in idle mode
0.8
1.6
0
160
160
546
138
Watt
Ampere
Watt
BTU/hr
Kcal/hr
Pink Noise
(1/8 rated
power)
8Ω / Stereo
2 x 2700
4.5
9
675
844
369
1088
275
16Ω / bridged 1 x 5400
4Ω / stereo
2 x 5200
7.9
15.8
1300
1625
525
1590
402
8Ω / bridged 1 x 10400
2Ω / stereo
2 x 9000
13
26
2250
2813
763
2366
598
4Ω / bridged 1 x 18000
Pink Noise
(1/4 rated
power)
8Ω / Stereo
2 x 2700
8
16
1350
1688
538
1494
377
16Ω / bridged 1 x 5400
4Ω / stereo
2 x 5200
14.7
29.3
2600
3250
850
2498
631
8Ω / bridged 1 x 10400
2Ω / stereo
2 x 9000
24.9
49.8
4500
5625
1325
4050
1023
4Ω / bridged 1 x 18000
*Power absorbsion with amplifier switched off is not zero because to comply with EN60065/IEC 60065:2001-
12 all amplifier circuitry must include a “bleed” resistor across the incoming AC mains power to discharge