Use
the
Edit2
Control
[8]
to
change
the
delay
by:
±1.000
ms
per
click,
or
±0.340
m
per
click,
or
±1.115
feet
per
click
Use
the
Edit3
Control
[9]
to
make
fine
adjustments.
The
Edit3
Control
changes
the
delay
by:
±0.0208
ms
per
click,
or
±0.007
m
per
click,
or
±0.023
feet
per
click
Turning
these
Controls
clockwise
increases
the
delay
time,
while
turning
them
anticlockwise
decreases
the
delay
time.
The
minimum
and
maximum
delay
ranges
from:
0.0000
ms
–
600.9984
ms
0.000
m
–
204.339
m
0.000
feet
–
670.233
feet
Press
the
ESC
button
[11]
to
disengage
Editing.
EQ
Bypass
EQ
Bypass
flattens
the
5
‐
Band
EQ
on
the
input
so
you
may
hear
exactly
how
it
is
affecting
the
system.
By
toggling
the
EQ
Bypass
on
and
off,
you
may
quickly
compare
the
sound
with
and
without
EQ.
Turn
the
Edit2
[8]
or
Edit3
[9]
Control
to
scroll
between
Bypass = Off
[default]
and
Bypass = On
.
Press
the
ESC
button
[11]
to
accept
the
new
EQ
Bypass
mode
and
exit
the
EQ
Bypass
editing
mode.
5
‐
Band
EQ
Editing
input
EQ
on
the
DX0.5
is
useful
for
adjusting
the
response
of
the
entire
PA,
particularly
when
correcting
anomalies
caused
by
venue
acoustics.
It
is
standard
practice
to
use
the
input
EQ
for
this
function
leaving
the
output
EQ
for
any
cabinet
EQ
recommended
by
the
system
manufacturer.
Press
the
Enter
button
[10]
to
enter
and
edit
the
EQ
bands.
An
arrow
–>
will
appear
next
to
EQ
indicating
that
it
is
ready
to
be
edited.
Use
the
Nav/Edit1
[7]
Control
to
change
the
frequency
by
±1/24
octave
per
click.
Turning
this
control
clockwise
increases
the
frequency,
while
turning
it
anti
‐
clockwise
decreases
the
frequency.
The
frequency
ranges
from
20.0
Hz
to
20.0
kHz.
Use
the
Edit2
[8]
Control
to
change
the
Q
factor
(bandwidth)
by
±0.05
per
click.
Turning
this
Control
clockwise
increases
the
Q
factor,
while
turning
it
anticlockwise
decreases
the
Q.
The
EQ
band
may
be
configured
as
high
or
low
shelf
by
turning
it
all
the
way
anti
‐
clockwise.
These
are
the
EQ
choices
from
the
furthest
anticlockwise
option
to
the
furthest
clockwise
option:
–12
High
Shelving
–6
High
Shelving
–12
Low
Shelving
–6
Low
Shelving
0.05
–
3.00
[Parametric]
To
change
the
EQ
between
shelving
and
parametric,
the
gain
must
first
be
set
to
0.0
dB.
Use
the
Edit3
[9]
Control
to
change
the
gain
by
±0.5
dB
per
click.
Turning
this
control
clockwise
increases
the
gain,
while
turning
it
anti
‐
clockwise
decreases
the
gain.
The
gain
ranges
from
–15.0
dB
to
+15.0
dB.
Summary of Contents for BlacklineX SERIES
Page 1: ...User Guide BlacklineX...
Page 2: ...BlacklineX USER GUIDE BlacklineX User Guide V1 0 1...
Page 6: ...BlacklineX USER GUIDE BlacklineX User Guide V1 0 5 X115 60 X118 60 X210 61 Warranty 62...
Page 59: ...BlacklineX USER GUIDE BlacklineX User Guide V1 0 58 Technical Drawings X8 X10...
Page 60: ...BlacklineX USER GUIDE BlacklineX User Guide V1 0 59 X12 X15...
Page 61: ...BlacklineX USER GUIDE BlacklineX User Guide V1 0 60 X115 X118...
Page 62: ...BlacklineX USER GUIDE BlacklineX User Guide V1 0 61 X210...