Product Installation
NOTE:
This product must be installed by a licensed electrician.
NOTE:
For best performance install at a height between 2 and 2.5 metres.
1.
Ensure the Mains Supply is switched ‘OFF’.
2.
wired to its own wall switch.
3.
Remove the mounting plate ‘A’ from light body ‘B’ by unscrewing the front screws ‘C’.
4.
Drill two holes in the wall using the mounting holes ‘D’ on the mounting plate ‘A’ as a template.
Note: exercise caution to avoid drilling into existing electrical wiring.
5.
Feed mains supply cable through the wall and weatherproof holes as appropriate. Pierce the rubber
grommet ‘G’ with a screwdriver and pass the mains supply cable through.
Connect the Live (L), Neutral (N), Earth(E) according to the markings on the terminal block ‘H’.
6.
7.
8.
9.
Apply silicone if required around the base plate and grommet ‘G’ to maintain IP rating.
10. Loosen the Screw in knuckle ‘K’ and angle the light head into desired direction, then
11. Reconnect the mains supply.
12. Turn on the security light.
•
Do not direct the heads upwards above horizontal.
screw
Introduction
•
Do not direct the heads upwards above horizontal.
BEFORE COMMENCING INSTALLATION
For the best performance we suggest you take into account the following:
light into its own circuit with its own switch.
The recommended mounting height is 2 to 2.5 metres.
Do not install on surfaces which can move or vibrate.
Installation Instructions
F
D
G
H
B
C
A
K
www.martecaustralia.com.au | 02 8778 7500 | [email protected]