IMPORTANT

READ CAREFULLY BEFORE INSTALLING FIXTURE.  RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.

PacLights fi xtures must be wired in accordance with the National Electrical Code and all applicable local codes.  Proper grounding is required for safety.  
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR 
WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.

WARNINGS:
• 

Make certain power is OFF before installing or maintaining fi xture.  No user serviceable parts inside.

• 

To prevent wiring damage or abrasion, do not expose wiring to edges of sharp objects.

CAUTION:
• 

For  proper weatherproof function all gaskets must be seated properly and all screws inserted and tightened fi rmly.  Apply weatherproof silicone 
sealant around the edge of the Back Box and/or Junction Box.  This is especially important with an uneven wall surface.  Silicone all plugs and 
unused conduit entries.

FIG. 1

  

 

FFLA/2 

15/30 

   FFLA/2 

50 

  FFLA/2 

70/90

The Selectable CCT & Lumen output is equipped on selected models.  
If the CCT or Lumen output needs to be adjusted or if the Photo 
Control turned on/off , remove the clear plastic Cap Screw from 
the back of the FFLA/

2

 fi xture (Fig. 1).  The Dip Switches can be 

accessed easliy inside the fi xture (Fig. 1a).   

Connect the ACL and the ACN from the FFLA/2 Fixture to the conduit with the AC power Supply Cable.  Follow the Wiring Diagram provided.

AC POWER SUPPLY

FFLA/2 DRIVER

GRA

Y (-)

PURPLE (+)

HOT [BLACK]

NEUTRAL [WHITE]

GROUND [GREEN]

WIRING DIAGRAM

DIM

INPUT

There is a Dip Switch Chart to follow next to the Dip Switches inside.  
The fi rst set of Switches controls the Lumen output.  The second set 
controls the Photo Control ON/OFF and the Color Temperature 
(Fig. 2).  After the selection is made replace the clear plastic Cap 
Screw and carefully tighten. 

BACK 
COVER

FFLA/2 FIXTURE

CAP SCREW

FIG. 1a

1

2

DIP SWITCHES

DIP SWITCHES

80%

100%

70%

90%

PH ON

PH OFF

3000K

4000K

5000K

FIG. 2

Summary of Contents for FFLA 2 Series

Page 1: ...s must be seated properly and all screws inserted and tightened firmly Apply weatherproof silicone sealant around the edge of the Back Box and or Junction Box This is especially important with an uneven wall surface Silicone all plugs and unused conduit entries FIG 1 FFLA 2 15 30 FFLA 2 50 FFLA 2 70 90 The Selectable CCT Lumen output is equipped on selected models If the CCT or Lumen output needs ...

Page 2: ...A 2 FIXTURE FIG 11 Loosen the Socket Head Screw on the Knuckle Mount and pull apart to separate the teeth and adjust the tilt angle to the desired position Once adjusted align the teeth and fasten the Screw to lock the Knuckle Mount and FFLA 2 fixture in place Fig 11 4 SCREW KNUCKLE MOUNT FFLA 2 FIXTURE The FFLA 2 Knuckle Mount can be mounted directly to a Junction Box Install the fixture to a J Box...

Page 3: ...rotated Loosen the center Cap Head Screws 2 and remove the smaller Cap Head Screws to adjust the tilt angle of the FFLA 2 fixture to point towards the desired location Replace the smaller Cap Head Screws and tighten all of the Cap Head Screws to hold the fixture in place Fig 16 4 FIG 16 ADAPTER SCREWS The Slipfitter Mount is only available for FFLA 2 70 90 fixtures If installed remove the Flood Mount ...

Page 4: ...asket Fig 23 3 FIG 23 FIG 22 SQUARE POLE ROUND POLE GASKET ARM MOUNT FIG 24 FIG 27 SCREW LOCKING PLATE SQUARE POLE GASKET MOUNTING POLE POWER CABLE Run the Power Cable through the Pole Place the Locking Plate and Gasket inside the Mounting Pole and fasten the FFLA 2 fixture with the Arm Mount onto the Pole with the Cap Head Screws Fig 27 For the Round Pole repeat Steps 2 6 except the remove the Squ...