Mart BR-11 User Manual Download Page 3

1 2 3

BR-11

A1

A2

S

TEST

MODE

1 2 3

BR-11

A1

A2

S

TEST

MODE

1 2 3

BR-11

A1

A2

S

TEST

MODE

1 2 3

BR-11

A1

A2

S

TEST

MODE

Fig. 2-1. Connection diagram of the BR-11 BISTABLE RELAY 

               > L signal control on S clamp
               > after turning the power on (N-L) - the receiver is off

                           

N

L

16A

 250VAC

(peak 100A)

2 3

1

5 mA

5 mA

5 mA

5 mA

> 2 s

> 2 s

> 2 s

> 2 s

40 ms...2 s

40 ms...2 s

40 ms...2 s

40 ms...2 s

S1

Fig. 2-2. Connection diagram of the BR-11 BISTABLE RELAY 

               > L signal control on S clamp
               > after turning on the power (N-L) - the receiver is on

                           

N

L

16A

 250VAC

(peak 100A)

2 3

1

S

S1

Fig. 2-3. Connection diagram of the BR-11 BISTABLE RELAY 

               > N signal control on S clamp
               > after turning the power on (N-L) - the receiver is off

                           

N
L

16A

 250VAC

(peak 100A)

2 3

1

S1

Fig. 2-4. Connection diagram of the BR-11 BISTABLE RELAY 

               > N signal control on S clamp
               > after turning on the power (N-L) - the receiver is on

                           

N
L

16A

 250VAC

(peak 100A)

2 3

1

S1

N

L

S1

Summary of Contents for BR-11

Page 1: ...ntiometer After this time the receiver will be automatically turned off The adjustment range of the switch off delay time is adjustable in the range 1 s 60 min the method of starting a given function can be changed with the TEST MODE button starting function I with a pulse longer than 2 s starting function II impulse within the range of 40 ms 2 s the switch off delay time can be set in one of thre...

Page 2: ... presses of the TEST MODE button change the way starting the function LED red starting function I with an impulse within the 40 ms 2 s interval starting function II with an impulse longer than 2 s Blue LED starting function I with an impulse longer than 2 s starting function II with an impulse within the range of 40 ms 2 s After setting each function wait 10 seconds for the settings to be accepted...

Page 3: ... 2 s 40 ms 2 s 40 ms 2 s S1 Fig 2 2 Connection diagram of the BR 11 BISTABLE RELAY L signal control on S clamp after turning on the power N L the receiver is on N L 16A 250VAC peak 100A 2 3 1 S S1 Fig 2 3 Connection diagram of the BR 11 BISTABLE RELAY N signal control on S clamp after turning the power on N L the receiver is off N L 16A 250VAC peak 100A 2 3 1 S1 Fig 2 4 Connection diagram of the B...

Page 4: ...nction II Impulse time T1 10 s Red LED is on Blue LED is on t t t t t t t t S S TEST MODE TEST MODE TEST MODE T1 T1 T3 T5 T1 T3 T2 T2 T4 T6 T4 T 2 s T 2 s T 2 s T 2 s T 2 s T 2 s T 2 s T 2 s 1s TP 60 min 1s TP 60 min 2 Selection of switch off delay time ranges Impulse time 5 s T1 10 s Red LED range 60 s Blue LED range 6 min LED red and LED blue range 60 min t 10 s t 10 s t 10 s t 10 s t 10 s t 10 ...

Reviews: