III. Installation

BISTABLE RELAY BR-11 may be installed only by a person authorized to operate electrical installations. 
Remember to choose the right protection.
On the front panel of the BR-11 BISTABLE RELAY, there are three informative LEDs: green, red and blue, and 
the TEST - MODE button.
On the side walls of the BR-11 BISTABLE RELAY there are: connection diagram and operating characteristics.

     

In order to connect the BISTABLE RELAY BR-11:
1. make sure the electrical system is turned off
2.connect the BISTABLE RELAY BR-11 according to the diagram (fig.1, fig.2) in the options:

    > S1 control signal from L voltage
    > S1 control signal from voltage N
    > when using terminals 1-2 - after switching on the power, the receivers are turned off
    > when using terminals 2-3 - after turning on the power, the receivers are turned on

3.switch on the supply voltage:

    > the green LED lights up
    > after 1 s they will flash twice - red LED and blue LED
    > after 2 seconds, the blue LED will light up, which indicates closed contacts 2-3

4.press the TEST-MODE button (less than 5 s)

    > the blue LED turns off and the red LED turns on
    > contacts 2-3 will open and contacts 1-2 will close
    > subsequent switching on of the TEST-MODE button will change the contact state

5. check operation with impulse switch

    > each subsequent switching on causes a change in the voltage status on the receiver and a change in the 
LED lighting:
       - blue - contacts 2-3 closed
       - red - contacts 1-2 closed

6.By using the TEST-MODE button, you can also select:

   >> turn-off delay time
     > press the TEST-MODE button for more than 5 seconds
     > when the LEDs blink (red LED, blue LED) - release the TEST-MODE button
     > successive presses of the TEST-MODE button change the ranges:
       

LED red - range 60 s, LED blue - range 6 min, LED red and LED blue - range 60 min.

       

After the control range is selected, the potentiometer is active on the selected range

   >> how to start the function
     > press the TEST-MODE button for more than 10 s
     > release the TEST-MODE button - successive presses of the TEST-MODE button change the way
       

starting the function:

        

LED red:

        > starting function I - with an impulse within the 40 ms ... 2 s interval
         > starting function II - with an impulse longer than 2 s
         

Blue LED:

         > starting function I - with an impulse longer than 2 s
         > starting function II – 

with an impulse within the range of 40 ms ... 2 s

After setting each function, wait 10 seconds for the settings to be accepted. After 10 seconds, the red LED and 
blue LED will go out for a moment, and the red LED and the blue LED will light up again for a moment. The 
LED (red or blue) will light up - the state of the relay before changing the settings.
7. the efficiently operating installation is ready for operation
8. BISTABLE RELAY BR-11 does not respond to impulse when the pause between successive pressings is 
shorter than 200 ms.
9. A schematic diagram of the operation of the BISTABLE RELAY BR-11 is shown in Fig. 3.

BISTABLE RELAY BR-11 can work with an unlimited number of switches without illumination and a limited 
number of switches with illumination, connected in parallel:

- neon illuminated connectors (1mA) <5 pcs.

 
  

Fig

1

An

 

exemplary

 

diagram

 

of

 

the

 

connection

 

of

 

the

 

BISTABLE RELAY

 

BR-11

           along

 

with

 

a

 

table

 

of

 

possible

 

connection

 

variants

.

IV. Technical data

Rated supply voltage LN

Rated frequency

Maximum load current (power):

resistive load

incandescent lamps

halogen lamps

fluorescent lamps

energy-saving lamps and LED

Instantaneous inrush current

Executive contacts

Rated power consumption 

Short

circuit

 

current

 

of

 

impulse

 

buttons

Response

 

time

 

to

 

the

 

impulse

 

button

Function

 

check

Time delay ranges

Times of starting functions I and II

Time

 

to

 

be

 

ready

 

again

Mechanical durability

Protection level

Cross

section

 

of

 

connection

 

cables

Installation 

Work position

Working temperature

Weight

230 VAC, + 10%, - 15%

50 Hz

16 A, AC1 (4 000 W) 

10 A (2500 W)

8 A (2000 W)

8 A (2000 W)

8 A (2000 W)

100 A

1 x NO, 1 x NC

 0,5 W

5 mA

< 40 ms

TEST-MODE button

60 s, 6 min, 60 min

 40 ms < T1 < 2 s,  T2 > 2 s or vice versa

> 200 ms

100 000 operations 

IP 20

2

0,2

÷

2,5 mm

One 18 mm field, 35 mm rail

Vertical

-40...+70 °C
80 g

N

L

16A

 250VAC

(peak 100A)

2 3

1

5 mA

S1

N

L

N

L

N

L

A2

A1

S1

1 2 3

BR-11

A1

A2

S

TEST

MODE

Summary of Contents for BR-11

Page 1: ...ntiometer After this time the receiver will be automatically turned off The adjustment range of the switch off delay time is adjustable in the range 1 s 60 min the method of starting a given function can be changed with the TEST MODE button starting function I with a pulse longer than 2 s starting function II impulse within the range of 40 ms 2 s the switch off delay time can be set in one of thre...

Page 2: ... presses of the TEST MODE button change the way starting the function LED red starting function I with an impulse within the 40 ms 2 s interval starting function II with an impulse longer than 2 s Blue LED starting function I with an impulse longer than 2 s starting function II with an impulse within the range of 40 ms 2 s After setting each function wait 10 seconds for the settings to be accepted...

Page 3: ... 2 s 40 ms 2 s 40 ms 2 s S1 Fig 2 2 Connection diagram of the BR 11 BISTABLE RELAY L signal control on S clamp after turning on the power N L the receiver is on N L 16A 250VAC peak 100A 2 3 1 S S1 Fig 2 3 Connection diagram of the BR 11 BISTABLE RELAY N signal control on S clamp after turning the power on N L the receiver is off N L 16A 250VAC peak 100A 2 3 1 S1 Fig 2 4 Connection diagram of the B...

Page 4: ...nction II Impulse time T1 10 s Red LED is on Blue LED is on t t t t t t t t S S TEST MODE TEST MODE TEST MODE T1 T1 T3 T5 T1 T3 T2 T2 T4 T6 T4 T 2 s T 2 s T 2 s T 2 s T 2 s T 2 s T 2 s T 2 s 1s TP 60 min 1s TP 60 min 2 Selection of switch off delay time ranges Impulse time 5 s T1 10 s Red LED range 60 s Blue LED range 6 min LED red and LED blue range 60 min t 10 s t 10 s t 10 s t 10 s t 10 s t 10 ...