ANNUAL MAINTENANCE
1. Replace motor brushes (Kit #
2. Perform Quarterly Maintenance.
TOASTER CONTROL DESIGNATION
Before any troubleshooting or replacement parts are ordered, it is necessary to determine the
style of control that your toaster has. Generation 2 started in March 2014, but older toasters may
or may not have been field upgraded from Generation 1 to Generation 2.
GENERATION
1
GENERATION
2
Buttons to the right of the LED display.
Buttons underneath the LED display.
TROUBLESHOOTING GUIDE
NOTE:
SERVICE MUST BE PERFORMED BY A QUALIFIED SERVICE COMPANY. THE
TERM "QUALIFIED SERVICE COMPANY" MEANS ANY INDIVIDUAL, FIRM,
CORPORATION OR COMPANY WHICH IS EITHER ENGAGED IN AND IS
RESPONSIBLE FOR THE INSTALLATION OR REPLACEMENT OF ELECTRICAL
COMPONENTS, OR THE CONNECTION, INSTALLATION OR REPAIR OF
ELECTRICAL APPLIANCES, WHO IS EXPERIENCED IN SUCH WORK, FAMILIAR
WITH ALL PRECAUTIONS REQUIRED, AND HAS COMPLIED WITH ALL THE
REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION.
WARNING:
INSPECTION, TESTING, AND REPAIR OF ELECTRICAL EQUIPMENT SHOULD BE
PERFORMED BY QUALIFIED SERVICE PERSONNEL. THE UNIT SHOULD BE
UNPLUGGED WHEN SERVICING, EXCEPT WHEN ELECTRICAL TESTS ARE
REQUIRED.
DANGER:
USE EXTREME CARE DURING ELECTRICAL CIRCUIT TESTS. LIVE CIRCUITS
WILL BE EXPOSED. WHERE TESTING INDICATES "WITH POWER OFF", BE
SURE THAT THE TOASTER IS UNPLUGGED.
1.
PROBLEM: Toaster shuts off intermittently and/or no heat and conveyor belts do not move.
(Will not turn on)
SOLUTION:
A) Check that toaster is plugged in. Check condition of power cord and plug.
B) Check circuit breaker in main breaker panel. Reset if necessary.
C) Check for error message. “AL1” message is a defective left platen probe. “AL2” is a defective
right platen probe. “AL3” is high temperature error of the left platen. “AL4” is high temperature
error of the right platens. All alarms will turn toaster off requiring a service call.