marsden MBF-6000 User Manual Download Page 4

 

Safety Instructions 

 

Before putting the device into use, please read with care the information given in this user 
manual, which contains important instructions for proper installation, use and maintenance 
of the device. 
 

When the scale is switched on, the display should read 0.0. If it doesn’t, press the ZERO key.

 

 
The device is designed to detect when a stable weight is achieved. The indicator will beep 
twice to indicate a stable weight value, at which point your reading can be taken. 
 
Marsden/the manufacturer shall not be liable for damages arising from failure to heed the 
following instructions: 

 

When using electrical components under increased safety requirements, always 
comply with appropriate regulations. 

 

Inappropriate installation/use will render the warranty null and void. 

 

Ensure the voltage marked on the power supply unit matches your mains supply. 

 

This device is designed for use indoors. 

 

Observe the permissible ambient temperatures for use. 

 

The device meets the requirements for electromagnetic capability. Do not exceed the 
maximum values specified in the applicable standards. 

 

Batteries should be kept away from small children. If swallowed, promptly seek 
medical assistance. 

 
If you have any problems, contact Marsden/your local dealer/your service partner. 

 

 

WARNING  TO  INDIVIDUALS  WITH  A  PACEMAKER  OR  OTHER  INTERNAL  MEDICAL 
DEVICES:  This  scale  sends  a  weak  electrical  current  through  the  body  during 
measurements.  Individuals  who  have  internally  implanted  medical  devices,  such  as 
pacemakers, should not use this medical equipment due to the risk of malfunction to 
the device that may be caused by the weak electrical current. 

 

Do not use this scale if you are pregnant. 

 

To reduce the risk of electrical shock or product damage, never insert or remove the 
power cable with wet hands. 

 

Do not under any circumstances dismantle or alter the device, as this could result in 
electric  shock  or  injury 

as  well  as  adversely  affecting  the  precision  of  the  scale’s 

measurements. 

 

Use  only  a  correctly  wired  (100-240VAC)  outlet,  and  do  not  use  a  multiple  outlet 
extension cable. 

 

Physically  disabled  persons  should  not  attempt  to  take  measurements  alone,  but 
instead should be assisted in using the device. 

 

Page 3 

Summary of Contents for MBF-6000

Page 1: ...USER MANUAL MBF 6000 MBF 6010 Please take time to read these instructions before starting to use the scale Version 1 3 10 20 Please keep this instruction manual to hand for future reference...

Page 2: ...uct Assembly MBF 6010 only 9 Before Operation 10 Setting Date Time 11 Operation Instructions 12 Assembly Instructions HM 201D 14 Replacing the Battery 15 Print out Readings Explained 16 Body Impedance...

Page 3: ...lular Water ECW 0 1L increments Skeletal Muscle Index SM 0 1kg m 2 increments Visceral Fat Area Level VFA 1 level increments Metabolic Age AGEM 0 1 year increments Body impedance 0 1ohm increments Hea...

Page 4: ...netic capability Do not exceed the maximum values specified in the applicable standards Batteries should be kept away from small children If swallowed promptly seek medical assistance If you have any...

Page 5: ...isassemble the equipment as this may cause malfunction Disposing of the Scale This product should not be treated as regular household waste but should be handed in to an electrical electronic equipmen...

Page 6: ...td No 103 Guozhong Rd Dali Dist Taichung City 412 Taiwan R O C Identification of manufacturer of medical product including address Type BF applied part Dispose of old appliances separately from your h...

Page 7: ...Product Structure MBF 6000 Page 6 A B C E D G F A Remote Display B Digital LCD C Control Panel D Pads for feet E Platform F Adjustable feet G Battery in holder...

Page 8: ...Product Structure MBF 6010 Page 7 A B C D E F G A Remote Display B Digital LCD C Control Panel D Pads for feet E Platform F Adjustable feet G Battery in holder...

Page 9: ...two people Page 8 1 Position the column of the MBF 6010 on top of the base as shown in the graphic on the left ensuring wires are neatly fed from the base through the inside of the column 2 Holding b...

Page 10: ...tery compartment of the indicator Alternatively plug the connector of the AC adaptor into the port on the indicator shown below Attach the printer to the scale using its 9D connector Ensure paper is i...

Page 11: ...The MBF 6010 will require some assembly The column will need to be screwed to the base location for screws is on the underside of the base For assistance call 01709 364296 Setting the Date Time Page 1...

Page 12: ...merical key on the control panel 4 Press TIME key to enter Date menu 5 Change the flashing digits by pressing the numerical key on the control panel 6 Press TIME entering Time menu 7 Change the flashi...

Page 13: ...s 5 Press ENTER then input your personal data A height reading will be displayed and the first digit will flash Input your height using the numerical keys Alternatively if you have an HM 201D height m...

Page 14: ...Assembly Instructions HM 201D Page 13...

Page 15: ...The connection point between the scale s indicator and HM 201D is illustrated below Insert the HM 201D data cable into the socket of the indicator before use Replacing the Battery Page 14...

Page 16: ...the battery housing Reset the rechargeable battery Make sure the rechargeable battery is properly placed 2 Place the battery housing back making sure that the housing pin is connecting to the right po...

Page 17: ...density and strength MM Muscle Mass The weight of muscles in the body As this increases the body is able to burn calories and energy faster This increases your basal metabolic rate BMR which helps th...

Page 18: ...et with the voltage measured on the heel This current flows from one lower limb through the lower abdomen and then into the other lower limb and the bio electrical impedance hereinafter impedance thus...

Page 19: ...contact Marsden or your local service representative Counting error too low Indicates that the signal from the loadcell is too low This error is normally caused by a serious fault on the scales such...

Page 20: ...ons and applications banned by the directive and for components the product is capable of being worked on at higher temperatures required by lead free soldering The restricted substances and maximum a...

Page 21: ...000 3 2 Class A Voltage fluctuations flicker emissions IEC 61000 3 3 Compliance Guidance and manufacturer s declaration electromagnetic immunity The MEDICAL SCALE MBF 6000 6010 is intended for use in...

Page 22: ...mains voltage prior to application of the test level Guidance and manufacturer s declaration electromagnetic immunity The MEDICAL SCALE MBF 6000 6010 is intended for use in the electromagnetic enviro...

Page 23: ...h as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the...

Page 24: ...of transmitter W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 7 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2...

Page 25: ...Directive 2014 31 EU Non automatic Weighing Instruments Directive Please see separate document showing on sticker of device for above CE marking Authorized EU Representative DISTRIBUTOR Manufactured...

Page 26: ......

Page 27: ......

Page 28: ......

Page 29: ...l sales marsdengroup co uk Manufacturing and Distribution Unit 7 Centurion Business Park Coggin Mill Way Rotherham S60 1FB Head Office Unit 1 Genesis Business Park Sheffield Road Rotherham S60 1DX www...

Reviews: