background image

Owner’s Manual  -  

RG/RADS Series

 

CW064IU-SCFN8

16120300000399

T h e  d es i g n  a nd  s pe c i f i c a t i o n s  a r e  su b j e c t  t o  c ha n g e  wi t h o u t  p r i or  n o ti c e  fo r  

p r o d u c t  i mp r o v e m e n t .  Co n s u l t  w i th  t h e  sa l e s  a ge n c y  or  m an u f a c t u r e r  f or  d e ta i l s .

A n y  u pd a t e s  to  t h e  ma n u a l  w i l l  be  u pl o a d e d  t o  t he  s er v i c e  we b s i t e ,  p le a s e  ch e c k

f o r  t he  l a te s t  v e rs i o n .

Congratulations on purchasing your new HVAC equipment. It’s 

been designed for long life and reliable service, and is backed 

by one of the strongest warranties in the industry. Your unit 

automatically qualifies for the warranty coverage listed below, 

providing you keep your proof of purchase (receipt) for the 

equipment and meet the warranty conditions.
LIMITED ONE (1) YEAR EXPRESS WARRANTY

&RPIRUW$LUH

 warrants this Room Air Conditioner to be free from 

defects in workmanship and materials for normal use and 

maintenance for one (1) year from the date of purchase by the 

original consumer. This Express Limited Warranty applies only when 

the Room Air Conditioner is installed and operated per 

&RPIRUW$LUH

 

installation and operating instructions for normal use. 

EXCEPTIONS

The Limited Express Warranty does not cover normal maintenance 

&RPIRUW$LUH

 recommends that regular inspection/maintenance be 

performed at least once a season. Additionally, labor charges  

diagnostic charges, transportation charges for replacement of 

refrigerant or filters, and any other service calls/repairs are not covered 

by this Limited Warranty. It also does not cover any portion or 

component of the system that is not supplied by 

&RPIRUW$LUH

regardless of the cause of failure of such portion or component.

&21',7,216)25:$55$17<&29(5$*(

8QLWPXVWEHRSHUDWHGDFFRUGLQJWR&RPIRUW$LUHRSHUDWLQJ

LQVWUXFWLRQV

included with the unit and cannot have been subjected 

to accident,

alteration, improper repair, neglect or misuse, or an act 

of God

(such as a flood)

• Serial numbers and/or rating plate have not been altered or

removed

Performance cannot be impaired by use of any product not

authorized by 

&RPIRUW$LUH

, or by any adjustments or

adaptations

to

components

Damage has not been a result of inadequate wiring or voltage

conditions, use during brown-out conditions, or circuit interruptions

• Air flow around any section of the unit has not been restricted
• Unit remains in the original installation

DURATION OF WARRANTY & REGISTRATION

The warranty begins on the date of purchase by the original 

consumer. The consumer must retain a receipted bill of sale as proof 

of warranty period. Without this proof, the express warranty begins on 

the date of shipment from the factory.

REMEDY PROVIDED BY THE LIMITED EXPRESS WARRANTY

The sole remedy under the Limited Warranty is replacement of the 

defective unit. Labor to diagnose and replace the defective unit is 

not covered by this Limited Express Warranty. If for any reason 

the replacement product is no longer available during the warranty 

period, 

&RPIRUW$LUH

 shall have the right to allow a credit in the 

amount of the current suggested retail price of the product instead 

of providing replacement. 

LIMITATION OF LIABILITY

There are no other express or implied warranties. 

&RPIRUW$LUH

makes no warranty of merchantability. We do not warrant

that the

unit is suitable for any particular purpose or can be

used in buildings or rooms of any particular size or condition

except as specifically provided in this document. There are no

other warranties, express or implied, which extend beyond the

description in this document.

All warranties implied by law are limited in duration to the one-term

of the warranty. 

We will not be liable for any consequential or

incidental damages caused by any defect in this unit.

This warranty gives you specific legal rights and you may also have

other rights which vary from state to state. Some states do not allow

limitation on how long an implied warranty lasts or do not allow the

exclusion or limitation of incidental or consequential damages, so

the above limitations or exclusions may not apply to you.

No warranties are made for units sold outside the continental

United States and Canada. Your distributor or final seller may

provide a warranty on units sold outside these areas.

 &RPIRUW$LUH

 will not be liable for damages if our

performance

regarding warranty resolution is delayed by events

beyond our

control including accident, alteration, abuse, war, government

restrictions, strikes, fire, flood, or other acts of God.

HOW TO SUBMIT A WARRANTY CLAIM

If you have a warranty claim, notify you installer or dealer promptly.  

KEEP THIS INFORMATION AS A RECORD OF YOUR PURCHASE

  PRODUCT IDENTIFICATION 

INSTALLATION

Model Number 

Installer Name (if used)

Serial Number 

Phone Number/Contact Information

Date of Purchase 

Date Installation Completed

Remember to retain your bill of sale as proof of warranty period.

LIMITED EXPRESS WARRANTY

&RPIRUW$LUH

_

-2018

Please visit 

www.

PDUVGHOLYHUV

.com

 

to register your new product

Summary of Contents for Comfort-Aire RAD-283Q

Page 1: ...ADS Series Window Type Room Air Conditioner RG 51Q RADS 51Q RADS 61Q RADS 81Q RADS 101Q RADS 121Q RADS 151Q RADS 183Q RADS 253Q RAD 283Q RADS 61R RADS 81R01 RADS 101R01 RADS 121R01 RADS 151R01 RADS 18...

Page 2: ...Owner s Manual RG RADS Series 2 Table of Contents Important Safety Instructions 03 Installation Instructions 1 Normal Sounds 2 Air Conditioner Features 2 Care and Cleaning Troubleshooting Tips...

Page 3: ...to heat generation Incorrect grounding may cause electric shock It may cause fire and electric shock It may cause fire It may cause explosion fire and burns It may cause electric shock or fire due to...

Page 4: ...s wax or thinner but use a soft cloth Ensure that the installation bracket of the outdoor appliance is not damaged due to prolonged exposure Hold the plug by the head of the power plug when taking it...

Page 5: ...U WR WKH UDWLQJ ZKHQ FKHFNLQJ WKH HOHFWULFDO UHTXLUHPHQWV H VXUH WKH DLU FRQGLWLRQHU LV SURSHUO JURXQGHG 7R PLQLPL H VKRFN DQG UH KD DUGV SURSHU JURXQGLQJ LV LPSRUWDQW 7KH SRZHU FRUG LV HTXLSSHG ZLWK...

Page 6: ...operating your new air conditioning unit Make sure to save this manual for future reference AVERTISSEMENT Ne pas utiliser de produits permettant d acc l rer le d gel ou de produits de nettoyage autre...

Page 7: ...WHG RQ WKH UHIULJHUDWLRQ HTXLSPHQW RU DQ DVVRFLDWHG SDUWV DSSURSULDWH UH H WLQJXLVKLQJ HTXLSPHQW VKDOO EH DYDLODEOH DW KDQG DYH D GU SRZGHU RU 2 UH H WLQJXLVKHU DGMDFHQW WR WKH FKDUJLQJ DUHD 1R LJQLWL...

Page 8: ...rode refrigerant containing components unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded 9 Checks...

Page 9: ...ching for or detection of refrigerant leaks A halide torch or any other detector using a naked flame shall not be used 11 Leak detection methods The following leak detection methods are deemed accepta...

Page 10: ...UHSHDWHG VHYHUDO WLPHV RPSUHVVHG DLU RU R JHQ VKDOO QRW EH XVHG IRU WKLV WDVN OXVKLQJ VKDOO EH DFKLHYHG E EUHDNLQJ WKH YDFXXP LQ WKH V VWHP ZLWK 2 1 DQG FRQWLQXLQJ WR OO XQWLO WKH ZRUNLQJ SUHVVXUH LV...

Page 11: ...Empty recovery cylinders are evacuated and if possible cooled before recovery occurs The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is a...

Page 12: ...Series 12 Installation Instructions Installation Instructions NOTE NOTE The unit you purchased may be look like one of the followings All the illustrations in this manual are for explanation purpose o...

Page 13: ......

Page 14: ...ware 3 8 Screws 4 Top Rail 1 R1 hardware 2 10 3 4 1 12 Weather stripping 5 PREPARE AIR CONDITIONER 2 3 INSTALL THE ACCORDION PANELS NOTE The top rail hardware and the Fig A Fig B and Fig C are not app...

Page 15: ...E OUTSIDE H About 3 4 to 1 for 5 to 8K Measure from the cabinet edge 3 H About 1 to 1 for 10 to12K 8 H Vinyl Clad Windows INSIDE OUTSIDE H About 3 4 to 1 for 5 to 8K Measure from the cabinet edge 3 H...

Page 16: ...ut the R1 insulation panel along the line Fig 12 INSTALL R1 HARDWARE only applicable to 15000Btu h Energy star models 7 or Instructions Measure the inner width of the side curtain 1 2 3 4 5 6 7 8 9 10...

Page 17: ...Fasten with nails or screws Storm window frame or other obstruction SASH 1 1 2 min 38 mm If AC is Blocked by Storm Window Fig 15 Add wood as shown in Fig 15 or remove storm window before air condition...

Page 18: ...lling this air conditioner NOTE Save Carton and these Installation Instructions for future reference The carton is the best way to store unit during winter or when not in use Do the following before s...

Page 19: ......

Page 20: ...ig 8 Fig 9 Fig 10 Fig 11 Fig 12 Install top angle and side Bracket Assemble Window Filler Panels 4 Place Cabinet in window Instructions 2 3 Plastic Frame Window Filler Panel Side Retainer 5 16 long he...

Page 21: ...l of sill and remove 2 Assemble sill angle bracket to support brackets at the marked position Fig 15B Hand tighten but allow for any changes later 3 Install support brackets with sill angle brackets a...

Page 22: ...x head screw into space between upper and lower sashes Fig 18 2 Attach right angle safety lock Fig 19 4 Attach the top angle to window frame Use a 3 32 drill bit to drill one hole through the hole in...

Page 23: ...nner width of the side curtain as shown Fig 20 Step 2 Remark a line on the provided R1 insulation panel according to a length 1 8 3mm less than the measured width in step 1 then cut the R1 insulation...

Page 24: ...raming material used HEIGHT Y inside model height plus twice the thickness of framing material used Fig 2 Fig 3 Fig 4 Fig 1 Instructions NAIL SPACERS TO STUDS LEVEL Caulks Required Aluminum Flashing O...

Page 25: ...ng in the masonry wall similar to the frame construction refer to Step 2 of Thru the wall Installation for a wall thickness greater than 8 1 2 2 Secure cabinet in place using masonry nails or the righ...

Page 26: ...the normal sounds otherwise it will void the warranty Water plug Model A Model B Water plug For some models Water plug Normal Sounds Sounds NOTE All the illustrations in this manual are for explanati...

Page 27: ...ything throughout the room as needed Move the Levers from side to side until the desired Left Right direction is obtained Air Directional Louvers Fresh Air Vent Control on 10 12 K MODELS Lever Air Dir...

Page 28: ...ol hi cool hi fan OFF TEMPERATURE MIN COOL MAX COOL LO FAN MED FAN MED COOL LO COOL HI COOL HI FAN OFF COOLING 1 2 3 4 5 6 7 Features MECHANICAL CONTROL OPERATING INSTRUCTIONS Cool Mode Fan Mode Therm...

Page 29: ...On Off Sleep Timer Check Filter Energy Saver Follow Me Ion Temp Temp Timer Timer On Off Sleep Check Filter Timer Auto Cool Dry Fan Low Auto Med High Clean Air Fan Mode Follow Me Energy Saver On Off Sl...

Page 30: ...de to set the heating function Use the Up and Down buttons to choose the desired temperature When heat Mode is selected the fan speed can be adjusted by pressing the fan button NOTE For some models th...

Page 31: ...ture in C or F and the Auto timer settings While on Fan only mode it shows the room temperature If the room temperature is too high or low it will display HI or LO Error codes AS Room temperature sens...

Page 32: ...to store the air conditioner during the winter remove it carefully from the window according to the installation instructions Cover it with plastic or return it to the original carton Be sure to unplu...

Page 33: ...coil set FAN ONLY mode FAN ONLY mode Thermostat set too cold for night time cooling To defrost the coil set to FAN ONLY mode Then set temperature to a Higher setting Problem Solution Air conditioner c...

Page 34: ...g OUTSIDE when unit is cooling Unit removing large quantity of moisture from humid room This is normal during excessively humid days Remote Sensing Deactivating Prematurely some models Remote control...

Page 35: ...urchase by the original consumer The consumer must retain a receipted bill of sale as proof of warranty period Without this proof the express warranty begins on the date of shipment from the factory R...

Page 36: ...J GLPHQVLRQDO GDWD RQ WKH DFWXDO SURGXFW SULRU WR EHJLQQLQJ DQ LQVWDOODWLRQ SUHSDUDWLRQV QFHQWLYH DQG UHEDWH SURJUDPV KDYH SUHFLVH UHTXLUHPHQWV DV WR SURGXFW SHUIRUPDQFH DQG FHUWLILFDWLRQ OO SURGXFWV...