Compatible with low voltage single stage gas, oil or electric heating or cooling systems and single stage heat
pumps. For use on 24VAC systems (not to exceed 30VAC) and 250mv to 750mv millivolt heating only systems.
WARNING!
• To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or cir-
cuit breaker box until installation is complete.
• This thermostat requires 2 AA Alkaline batteries for power.
• Do not use this thermostat on applications with voltages above 30VAC.
• Wiring must conform to all local and national building/electrical codes and ordinances.
• Do not short (jumper) across terminals on the gas valve or at the system control to test the installation. This
will damage the thermostat and void the warranty.
• This thermostat is equipped with automatic compressor protection to prevent damage due to short cycling.
The short cycle protection provides a 5-minute delay between heating (heat pump models) or cooling cycles to
prevent the compressor from being damaged.
• Do not switch the system to cool if the outdoor temperature is below 50 F (10 C). This may damage the cool-
ing system and may cause personal injury.
• This thermostat should be used only as described in this manual.
SPECIFICATIONS
Electrical Rating:
24 Volt AC (18-30 VAC), 1 Amp Maximum per Terminal, 3 Amps Total Load
Control:
1 Heat / 1Cool Single Stage Heat Pump
Set Point Range:
45 F – 90 F (7.0 C – 32.0 C)
Program:
[Mon-Tue-Wed-Thur-Fri] & [Sat] & [Sun]
Set Points:
Morn, Day, Eve, Night
Advanced Recovery:
Yes
Accuracy:
+/- 1 F (.5 C)
Terminations:
RC, RH, G, Y, W, B, O
Power:
3 VDC (2 AA Alkaline batteries)