![MARS COMMERCE ZEUS4-MC Lite Installation Manual Download Page 46](http://html.mh-extra.com/html/mars-commerce/zeus4-mc-lite/zeus4-mc-lite_installation-manual_1730653046.webp)
ZEUS4-MC Lite
INSTALLATION MANUAL
42
19
GPRS-TCP/IP CONFIGURATION
To start the GPRS-TCP/IP connection user must set just a few parameters. They are described
below.
19.1
IPEN
This parameter is used to enable GPRS-TCP/IP connection.
Possible values:
0 – GPRS-TCP/IP connection is disabled
1 – GPRS-TCP/IP connection is enabled
19.2
IPCID
This parameter is used to enable sending local events (built in CID) and events received as Ademco
Contact ID format from the alarm control panel.
Possible values:
0 – Event sending over GPRS-TCP/IP connection is disabled
1 – Event sending over GPRS-TCP/IP connection is enabled
19.3
IPAPN
This is an Access Point Name for GPRS-TCP/IP connection.
Example:
;IPAPN=internet.simobil.si; … setting for Si.mobil Slovenia (MCC/MNC code: 29340)
NOTE
If this parameter is not set the device will not try to initiate GPRS-TCP/IP connection.
19.4
IPUSR
This is a user name for GPRS-TCP/IP connection.
Example:
;IPUSR=simobil; … setting for Si.mobil Slovenia (MCC/MNC code: 29340)
19.5
IPPSW
This is a user password for GPRS-TCP/IP connection.
Example:
;IPPSW=internet; … setting for Si.mobil Slovenia(MCC/MNC code: 29340)