08=&
1589.33.9165 4.5;.3
./21 $(
9.5.8
Table of parameters
Name
Comment
UDC
Tel. number of GSW1 device
RAN
Auto answer ring number
TST
SMS test time out
MNF
Manual GSM provider selection
ARST
Time out control for automatic system restart
ADF
Auto dial functionality ( Call TN1 )
LNG
Language selection
BUZ
Buzzer control
Table 11: Set-up parameters
Example:
'
Programming with short text messages - SMS
GSW1 PROGRAMMING TABLE
Name
Number
Description
MNF
29340
Manual fixing of the GSM provider (Simobil)
LNG
1
Switch on Italian language
ADF
90
Make voice call every 90 days
TST
24
24 hours periodic test SMS
BUZ
0
Mute buzzer
Table 12: Set-up parameters example
'
Remote programming by SMS
;MFN=29340;LNG=1;ADF=90;TST=24;BUZ=0;
9.6 SMS MESSAGES EDITOR
You can write and send a short SMS message for each alarm input. The default message is English,
but it is possible to change language with LNG parameter. Each message is built from 3 parts and
user can write the first (User Location) and the second (alarm event) part of the message. Unit adds
the third part (alarm event description) automatically. Language of the 3rd part may be changed by
LNG
parameter. The message is stored in the SIM phone book so you should add any number for
correct operation.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
#
0
U
S
E
R
L
O
C
A
T
I
O
N
#
1
I
N
P
U
T
1
NOTE
Message should not be longer than 14 characters! Space is also counted as one
character!