3. 3. 1  SUPPLIES ON REQUEST 

It is to be understood that any modification and/or addition of accessories must be explicitly approved 
of and carried out by the Manufacturer. 

A ... 

WARNING 

Any alteration or modification of the fridge made by the 

operator and/or service operator is forbidden for security 

reasons. 

The manufacturer decline any responsibility for 

unautorizated modifications.  

 

3. 4   ELECTROMAGNETIC ENVIRONMENT 

The refrigerator is designed to function correctly in an industrial electromagnetic environment, coming within 
the Emissions and Immunities foreseen by the following regulations: 

EN 50081-2 Electromagnetic compatibility - General regulation for emission Part 2 Industrial environments - 
(1993) 

EN 50082-2 Electromagnetic compatibility - General regulation for Immunity Part 2 Industrial environments - 
(1995) 

4. SAFETY 

4. 1 

GENERAL WARNING 

The user must read very carefully the information given in this Manual, with particular attention to the 

appropriate precautions for Safety listed in this chapter. 
It is imperative that the User follows the list below: 

Keep the refrigerator clean and tidy;

Do not remove or alter the plaques placed by the Manufacturer (see 4.6);

Do not remove or bypass the safety systems;

Do not touch the equipment with damp or wet hands or feet;

Do not touch the equipment with bare feet;

Do not insert screwdrivers or anything else between the protective cover and the moving parts;

Do not pull the power cable to disconnect the appliance from the power supply;

Before carrying out any cleaning or maintenance operation, disconnect the appliance from the electric

power supply, first switching off the main switch and then removing the plug.

4. 2 

FORESEEN USE 

The upright and/or table refrigerator has been conceived and built to be used in communities, restaurants, 
hotels etc. 

4. 3 

UNSUITABLE CONDITIONS FOR USE 

The upright and/or table refrigerator must not be used : 

For purposes which differ from those shown in 4.2

In an explosive, aggressive atmosphere or where there is a high concentration of oily substances or
powders suspended in the air ;

In an atmosphere with a fire risk ;

Exposed to bad weather ;

With adapters, multiple sockets or extension leads.

Summary of Contents for GFZ225

Page 1: ...PREP TABLES AND REFRIGERATED CABINETS Use and Maintenance Brick Oven Cooking Solutions...

Page 2: ......

Page 3: ...age 8 5 1 TRANSPORT AND MOVEMENT 5 2 STORAGE 5 3 CHECKS 6 INSTALLATION page 8 6 1 SET UP 6 2 ASSEMBLY 6 3 PREARRANGEMENTS 6 4 CONNECTIONS 6 4 1 ELECTRIC 6 4 2 HYDRAULICS 6 4 3 PREARRANGEMENTS FOR OPTI...

Page 4: ...VICE CENTRES Sales Service Spare parts and Commercial Representation For any requirement pertaining to use maintenance or the request for spare parts the Customer should use an authorised Service Cent...

Page 5: ...hnical aspects Operation Stopping Maintenance Spare Parts and Safety Before carrying out any operation on the equipment the User and the Qualified Technicians must carefully read the instructions cont...

Page 6: ...which the evaporator comes into contact with So when coming out of the evaporator the vapours of the refrigerating fluid are sucked out by an air compressor and sent to the condenser If the latter ta...

Page 7: ...ted in this chapter It is imperative that the User follows the list below Keep the refrigerator clean and tidy Do not remove or alter the plaques placed by the Manufacturer see 4 6 Do not remove or by...

Page 8: ...sure that all power sources have been switched off For this reason in the upright and or table refrigerator it is necessary to deactivate The electric plant putting the main switch off and pulling ou...

Page 9: ......

Page 10: ...g the Electrical apparatus PLAQUE C Earth symbol Plaque regarding the Electrical apparatus PLAQUE D Warning The manufacturer and the retailer decline all responsibility if the power line is not protec...

Page 11: ...nsibility to file a freight claim with the freight company Before removing the product from the shipping skid PLEASE READ CAREFULLY or damage will occur that will not be covered under warranty Because...

Page 12: ...electrical issues that can and will void the warranty Both units require separate 20Amp circuits to operate properly The use of extension cords is not allowed and will affect the operation Now you ar...

Page 13: ...fully lift the condiment rail onto the side and back splashes and center it ensuring that the sides and back have not moved and are square Please allow 24 hours for silicone to cure before using Any e...

Page 14: ...of each type of table The temperature can be programmed up or down the defrost cycles are preprogrammed and it will display any error codes After 15 seconds the unit will show cooling and display the...

Page 15: ...re down The rail must have pans all of the way across the rail to hold temperature of the product The product must be covered during slow periods or the product may start to absorb heat At night remov...

Page 16: ...temperature push and hold the set button for 5 seconds and machine status will appear press the set key and using the up or down arrow keys go to Set press the set key and using the up or down arrow k...

Page 17: ...airs or substitution of damaged parts is at the Customer s expense 5 2 STORAGE In the case of long periods of inactivity the upright and or table refrigerators must be stored with attention to the rel...

Page 18: ...he side tab in the appropriate place on the sides or on the table supports Fig 2 Slide the shelf into the supports as shown in Fig 2 Slide into the appropriate runners on the lower part of the refrige...

Page 19: ...nd or tables are switched on is good to attend to the instruction as follow 6 4 1 ELECTRICAL The electrical connection of the upright and or table refrigerator is the Customer s responsibility The con...

Page 20: ...and install the appliance must possess or acquire through adequate formation and training the following skills and must understand the contents of this manual and all the relevant Safety Information...

Page 21: ...oor which has just been closed 7 6 CONSERVATION OF FOOD The main cause of the degradation of food and other organic substances is the multiplication of bacteria contained in the cold storage rooms whi...

Page 22: ...on switch off the appliance remove the power cable and proceed as follows With the use of an air jet or dry brush with rigid bristles eliminate with a vertical movement as shown in Fig 6 the dust and...

Page 23: ...tight Contact technical assistance Contact technical assistance Close door Ice blocks on evaporator Improper use Control Panel is broken Contact technical assistance Contact technical assistance Pool...

Page 24: ...n of Conformity with Regulation 98 37 CE Declaration of Conformity with Regulation 89 336 CE Declaration of Conformity with Regulation 73 23 CE 13 2 TECHNICAL DOCUMENTATION The following technical doc...

Page 25: ...dici dei ricamb ange without notice Pl potrebbere comb ease contact servi are senza ce desm p r eavvis o Riv o lgersi on f or any update a serv ce desm on it per aggiornamenti 16 Spare Parts m anual M...

Page 26: ...890100410DX UPPER RIGHT HAND DOOR HINGE BRACKET 1 34 R25 0054 FUSE HOLDER 503Si 1DS 170301 ADELS C 2 12 890100410SX UPPER LEFT HAND DOOR HINGE BRACKET 1 35 Q32 0411 TRANSFORMER TF511113 115 12V UL PMA...

Page 27: ...Rev 11 2020...

Page 28: ...n i 1 0 3 1 0S o u t h a r dD r B e l t s v i l l eMD2 0 7 0 5 P h o n e 8 8 8 2 3 9 0 5 7 5 F a x 2 4 0 6 6 7 7 9 9 1 E ma i l i n q u i r i e s ma r r a f o r n i c o m We b w w We b w w w ma r r a...

Reviews: