Fireplace Installations in Covered Outdoor Locations
Kingsman and Marquis Direct Vent fireplaces may be installed into outdoor locations provided they are suitably protected
from direct water impingement.
However, all installation clearances in the appliance manual must be observed. Framing, Clearances to
Combustibles, Mantel Heights, Facing Requirements, Venting Installation, etc.
Use supplied Safety Screen.
A
Minimum
sheltering cover (overhang) of
1/2 the distance from the base of the fireplace
to the ceiling
(base of roofline) is required.
EXAMPLE:
The bottom of the
fireplace is
84”
from the ceiling.
Therefore,
42”
of
sheltering cover is
required above
fireplace.
All wiring connections to line
power shall be in accordance
with outdoor requirements of;
-NECA NFPA 70 in the USA
-Canadian Electrical Code, CSA
C22.1 for Canada.
Outdoor Area
(Deck)
Indoor Area
(Living Room)
⚠
NOTE: TEMPERED
GLASS WARNING:
Tempered glass is
vulnerable to rapid
and/or extreme changes
in temperature (thermal
shock). Take care to
prevent water from
contacting the fireplace,
especially if it is hot.
NOTE:
See-Through Units
are
suitable for an outdoor location,
but not on the outside wall of a
house or other structure, as air
flows through both sides of the
fireplace.
Outdoor
Area
42”
84”
96”
12”
Outdoor
Area
42”
84”
96”
12”
Glass
Door
Glass
Door
The Fireplace is not to be operated in
temperatures below freezing (0°C / 32°F).
9
Summary of Contents for Marquis BZDV4736NE
Page 44: ...Gas Conversion for Modulator PART C WARNING WARNING 44...
Page 47: ...Pilot Shield RSP1 RSP2 Qty 1 Shield Per Kit Back View 1 2 3 4 5 6 SLOTS SLOTS SLOTS SLOTS 47...
Page 58: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 58...
Page 65: ...Proflame 2 Remote Control 65...
Page 67: ...67...