Marquis Marquis BZDV4736NE Installation Instructions Manual Download Page 21

 

4236RB-SRKP*  Upgrade Kit 

*NOTE

: THE 

MQRB4236N 

CANNOT BE CONVERTED TO LP. 

If the 

MQRB4236NT

 you wish to convert to LP has a serial 

number less than 

#4708

  

You MUST order the 4236RB-SRKP upgrade kit.

 

 

Valve System Parts - 

New Top convertible SIT (Millivolt) 

1000-P136WR   Thermopile GOAI-524 
1001-P069SI  

Electrode Sparker 915.069 TC SIT 

1001-P216SI  

Thermocouple 290.216 TC SIT 

1001-P165SI  

Orifice Pilot NG 977.165 TC SIT 

1001-P167SI  

Orifice Pilot LP 977.167 TC SIT 

1001-P633SI  

Valve Nova LP Hi/Lo 0820651 

1001-P634SI  

Valve Nova NG Hi/Lo 0820652 

1001-P713SI  

Pilot Burner LP 199.713 TC SIT 

1001-P714SI  

Pilot Burner NG 199.714 TC SIT 

Remote Control / Millivolt 

GFRC  -Remote Control Millivolt / IPI 

– On/Off 

GTRC  -Remote Control Millivolt - Thermostat 
GTMRCN -Remote Control Millivolt 

– Thermostat/Modulating - NG 

GTMRCP -Remote Control Millivolt 

– Thermostat/Modulating - LP 

GTFRCN -Remote Control Millivolt 

– Thermostat/Modulating/Fan 

(NG) 

GTFRCP -Remote Control Millivolt 

– Thermostat/Modulating/Fan  

(LP) 

Electronic Ignition/Remote Control IPI 

*In the U.S.A. Thermostats are not permitted for Vented Gas 
  Fireplaces (ANSI Z21.50b) 
EGTRC              Remote Control IPI (Thermostat) 
EGTMRCN        Remote Control IPI (Thermostat/Modulating - NG) 
EGTMRCP        Remote Control IPI (Thermostat/Modulating - LP) 
EGTFRCN  Remote Control IPI (Thermostat/Modulating/Fan - NG) 
EGTFRCP   Remote Control IPI (Thermostat/Modulating/Fan - LP) 

Electronic Ignition Replacement Parts IPI 

1002-P001si  

Valve IPI (NG; ON/OFF) 

1002-P002si  

Valve IPI (LP; ON/OFF) 

1006-P002si  

Valve IPI (NG; Hi/Lo) 

1006-P603si  

Valve IPI (LP; Hi/Lo) 

1002-P047si  

Pilot Assembly (LP) 

1002-P033si  

Pilot Assembly (NG) 

1002-P089si  

Spark Electrode (Long) 

1002-P113si  

Electrode Flame Sensor (Long) 

1002-P302si  

IPI Ignition Board 

1002-P850si  

AC Wall Adapter 

1002-P12BH  

Battery Pack 

1002-P912si  

Wiring Harness 

1002-P166si  

Orifice Pilot (NG #62) 

1002-P168si  

Orifice Pilot (LP #35) 

1002-P013si  

Stepper Motor (NG) 

1002-P012si  

Stepper Motor (LP) 

1002-P016is  

Hi/Lo Regulator (NG) 

1002-P014si  

Hi/Lo Regulator (LP) 

Miscellaneous Parts 

1000-150GE  

#Silicone GE Red IS806 #736 

1000-150MP  

#Hi-Temp Mill Pac Sealant 840099 

1000-214  

#Piezo-Igniter 1244-17 MARK 21 

1000-215  

#Pal Nut (18MMXI.5MM)BLK (1364.03) 

1000-218  

#Switch Ivory (1451/001) 

1000-227  

#Cover Ivory (86001/001) 

1000-255  

#Orifice Brass - (State Size) 

1000-EMBER  

#Moon Rock 

2000-080  

#Thermodisc 2450 (For Blower) 

2000-081  

#Blower Motor QLN65/2400 

1000-085  

#Control Variable Speed KBWC-13BV 

1000-306  

Thermalcord - Adhesive Back for Door Frame 

42HB-310  

Ceramic Glass 

36HB-123  

Upper Door Spring 

OFP42SA  

Spark Assist

 

Kingsman Fireplace Venting 

Number  

 

Description 

 

ZDVHSK  

Horizontal Vent Starter Kit - 3 FT Length 

 

 

Horizontal Vent Termination, Wall Thimble, 

 

 

36” Flex Pipe, Mill Pac, screws/washers,  

 

 

springs. 

ZDVHSK5  

Horizontal Vent Starter Kit - 5 FT Length 

 

 

Horizontal Vent Termination, Wall Thimble, 

 

 

60” Flex Pipe, Mill Pac, screws/washers,  

 

 

springs. 

FDVVT40  

Vertical Vent Termination converts from 

 

 

15’-40’ to 15’ and under 

FDVHT    

Horizontal Vent Termination 

FDVHSQ  

Horizontal Square Termination 

ZDVST    

Horizontal Snorkel Termination 

 

 

(34” Tall, 24” Center to Center) 

FDVHSC  

Safety Cage for Horizontal Termination 

ZDVAIS   

Attic Insulation Shield 

ZDVVOS  

Offset Support 

ZDVFS    

Firestop Spacer 

ZDVRS   

Roof Support 

ZDVWT   

Wall Thimble (Horizontal Venting) 

ZDVSSLR  

Siding Shield - Large Return 

ZDV48GP  

Galvanized Pipe 7” Dia. x 48”  

 

 

(Vertical Installations) 

ZDVAAF  

Flashing 7” c/w Storm Collar (1/12 to 7/12) 

ZDVAF2  

Flashing 7” c/w Storm Collar (8/12 to 12/12) 

ZDVAF3  

Flashing 7” c/w Storm Collar Flat 

ZDV7SC  

Storm Collar 7” 

ZDVFK5  

Flex Kit (4” & 7” Dia.) x 2.5’ (Unexpanded)  

 

 

5’ Expanded 

ZDVFK8 Flex Kit  

(4” & 7” Dia.) x 4’ (Unexpanded)  

 

 

8’ Expanded 

ZDVFK20 Flex Kit (4” & 7” Dia.) x 10’ (Unexpanded)  
 

 

20’ Expanded 

 

            *Kits are complete with spring stand-offs, silicone. 

ZDV4FC  

Flex Connector 4” Diameter 

ZDV7FC  

Flex Connector 7” Diameter 

ZDV4SS  

Spring 4” Standoff Spacer 

ZDVDFA  

Simpson Dura-Vent Fireplace Adapter 

 

 

(for ZDV33/36/42/47, ZDV6000, MDV31 & 

 

 

HB models) 

ZDVHSKSQ  

Horizontal Square Termination Vent Starter 

 

 

Kit - 3 FT Length 

 

 

Horizontal Vent Termination, Wall Thimble, 

 

 

Wall Thimble, 36” Flex Pipe, Mill Pac 

ZDVHSKSQ5  

Horizontal Square Termination Vent Starter 

 

 

Kit - 5 FT Length 

 

 

Horizontal Vent Termination, Wall Thimble, 

 

 

Wall Thimble, 60” Flex Pipe, Mill Pac 

FDVHSQ  

Horizontal Square Vent Termination

 

21

Summary of Contents for Marquis BZDV4736NE

Page 1: ...NTED GAS FIREPLACE A Division of R Co Inc 2340 Logan Avenue Winnipeg Manitoba Canada R2R 2V3 Ph 204 632 1962 Printed in Canada September 4 2018 Part 36MQ MAN14 INSTALLER Leave this manual with the app...

Page 2: ...g Requirements 24 Installing Clean View Kit CVCK 25 Clearance to Combustibles 25 Parts List 26 27 Kingsman Fireplace Venting Parts 27 COMMON SECTION Clearance Mantels Surrounds 28 29 Dimensions Instal...

Page 3: ...Climates CPI Setting 64 Flame Control Room Thermostat 65 Smart Thermostat Fan Speed Control Light Control 66 Label Schematic 67 VENTING SECTION Vent Termination 68 General Vent Installation Informatio...

Page 4: ...e with the fan off if a fan is present after the curing of the paint has been completed These odours can last upward to 40 hours of burn time keep burning at a minimum of four hours per use until odou...

Page 5: ...until unit is COMPLETELY cool before touching glass or attempting to install or remove Child Safety Screens To install screens hook bottom clip onto glass door frame then press down and push upper cli...

Page 6: ...LLED IN MANUFACTURED MOBILE HOMES IN CANADA Please follow the current ANSI NFPA 70 National Electrical Code in the USA and CAN CSA C22 1 Canadian National Electrical Code in Canada An appliance must b...

Page 7: ...ce 15 Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning ma...

Page 8: ...in the living area outside the bedroom s The carbon monoxide detector shall comply with NFPA 720 B A carbon monoxide detector shall be located in the room that houses the appliance or equipment and sh...

Page 9: ...ceiling Therefore 42 of sheltering cover is required above fireplace All wiring connections to line power shall be in accordance with outdoor requirements of NECA NFPA 70 in the USA Canadian Electrica...

Page 10: ...on Wall Corner F Exterior Wall See Mantel Leg Clearances Instruction for the proper placement of fireplace Island installation with a top vent is possible as long as the horizontal portion of the vent...

Page 11: ...e the elbow on any horizontal runs of one foot or greater This allows for cleaner combustion and greatly reduces carboning and cleaning of glass MQHBZDV3636 Framing for your Gas Fireplace MQHBZDV36 Lo...

Page 12: ...CIRCULATING KIT HB36CVCK WITH MQHB36SW SURROUND HBZDV36 Framing and Facing Requirements Non Combustible Header Attached AA Non Combustible Header Attached AA AA AA Non Combustible Header Attached AA...

Page 13: ...rance to Combustibles Back from Standoffs 0 inches 0 mm Side from standoffs 0 inches 0 mm Floor 0 inches 0 mm Ceiling from bottom of fireplace 60 inches 150 cm Top from standoffs 0 inches 0 mm Top of...

Page 14: ...Millivolt Z1MT Thermostat Millivolt Wall Mount Z80PT Thermostat Programmable Digital Millivolt Wall Mount 1F80 40 GTRC Remote Control Millivolt Thermostat GTMRCP Remote Control Millivolt Thermostat M...

Page 15: ...36 42 47 ZDV6000 MDV31 HB models ZDVHSKSQ Horizontal Square Termination Vent Starter Kit 3 FT Length Horizontal Vent Termination Wall Thimble Wall Thimble 36 Flex Pipe Mill Pac ZDVHSKSQ5 Horizontal S...

Page 16: ...on Wall Corner F Exterior Wall See Mantel Leg Clearances Instruction for the proper placement of fireplace Island installation with a top vent is possible as long as the horizontal portion of the vent...

Page 17: ...of two and a half 2 5 inches above the bend in enclosures 5 For a fireplace with louvers combustible floor can raise 1 above the bottom of the fireplace For a fireplace with HB42CVCK Clean view Circu...

Page 18: ...AN VIEW CIRCULATING KIT HB42CVCK WITH MQHB42SW SURROUND Note A HBCVCK must be used when installing a MQHBSW Wall Surround HB42 Framing and Facing Requirements Non Combustible Header Attached Non Combu...

Page 19: ...ombustibles Back from Standoffs 0 inches 0 mm Side from standoffs 0 inches 0 mm Floor 0 inches 0 mm Ceiling from bottom of fireplace 60 inches 150 cm Top from standoffs 0 inches 0 mm Top of 90 degree...

Page 20: ...ge 37 3 8 H x 43 3 8 W HB42SLBL Surround Slim Line Gun Metal Black Coverage 37 3 8 H x 43 3 8 W Designer Doors for 42 Fireplaces Operative HB42DDA1BL Designer Door Arch Series 1 Black HB42DDTA1A Trim...

Page 21: ...ne GE Red IS806 736 1000 150MP Hi Temp Mill Pac Sealant 840099 1000 214 Piezo Igniter 1244 17 MARK 21 1000 215 Pal Nut 18MMXI 5MM BLK 1364 03 1000 218 Switch Ivory 1451 001 1000 227 Cover Ivory 86001...

Page 22: ...on Wall Corner F Exterior Wall See Mantel Leg Clearances Instruction for the proper placement of fireplace Island installation with a top vent is possible as long as the horizontal portion of the vent...

Page 23: ...nsulation sleeve is not required 5 For a fireplace with louvers combustible floor can raise 1 above the bottom of the fireplace For a fireplace with HB47CVCK Clean view Circulating Kit floor or hearth...

Page 24: ...Non Combustible Header Attached Non Combustible Header Attached Non Combustible Header Attached Non Combustible Header Attached 24...

Page 25: ...fs 0 inches 0 mm Floor 0 inches 0 mm Ceiling from bottom of fireplace 60 inches 150 cm Top from standoffs 0 inches 0 mm Top of 90 degree bend in Minimum with insulation sleeve Enclosure of 50 1 2 to 5...

Page 26: ...the U S A Thermostats are not permitted for Vented Gas Fireplaces ANSI Z21 50b Z2MT Thermostat Digital Vertical Wall Mount MV PF1 Z80PT Thermostat Programmable Digital Wall Mount MV PF1 GFRC Remote C...

Page 27: ...al Vent Termination FDVHT Horizontal Vent Termination FDVHSQ Horizontal Square Termination Z47ST24 Horizontal Snorkel Termination 24 Tall 14 1 2 Center to Center Z47ST36 Horizontal Snorkel Termination...

Page 28: ...the minimum height and width requirements for a combustible mantel Note For the installation of the MQHBSW Maintain Minimum 1 Clearance to Top Sides of the surround Combustible or non combustible mate...

Page 29: ...r over the front face of the fireplace NO PORTION OF GRILL AREA OR DOOR AREAS CAN BE COVERED except where designer clean view kit is used Combustible material can extend flush to unit up to the top bo...

Page 30: ...mounting holes on the Lower Tab with the holes on the CVCK Side Frame Using the previously removed screws in Step 1 secure the Lower Tab to the CVCK side frame Replace the old CAP with the new CAP th...

Page 31: ...set screw on the side of vari able speed controller to increase or decrease the minimum fan speed lowering minimum fan speed will decrease sound level created by fan Reinstall switch into wall mount a...

Page 32: ...pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Label all wires prior to disconnection when servicing con...

Page 33: ...Remove 2 DT Screws from Firebox sides Do not discard these screws Place Side Panels into Firebox as shown in Ref 3 below tilt and slide into place Replace and tighten DT Screw through hole in top of S...

Page 34: ...ce optional front bridge ledge 3 in the area front of false bottom 5 Place rear Brick Panel 4 up against the rear of Firebox by tilting top of panel towards you and sliding bot tom of Panel over the b...

Page 35: ...k Clip out of the way and slide Side Panel up against Back Panel Side Panel tabs should engage top and bottom of Back Panel See Ref 3 Rotate Brick Clip down over Side Panel and tighten screw 5 Re inst...

Page 36: ...essures in excess of 1 2 PSIG 3 5 KPa 9 The appliance must be isolated from the gas supply piping system by closing its individual shutoff valve during any pressure testing of the gas supply piping sy...

Page 37: ...ay and hold it With the other hand push in the red ignitor button until you hear a click Now observe closely the pilot burner located on the rear center left hand side of the main burner If a flame ha...

Page 38: ...itch If okay jumper wires across wall switch wires at valve If burner comes on wires are faulty or connections are bad Generator may not be Check generator with millivolt meter Take reading at gen gen...

Page 39: ...ing Burner System 1 Disconnect gas line connection at burner system through access cover opening CAUTION ALL WORK SHOULD BE PERFORMED BY A QUALI FIED AND CERTIFIED TECHNICIAN 2 Remove extension knobs...

Page 40: ...intermittent or standing pilot system even if the main burner was never on Exercise caution when working within the area ALL WORK SHOULD BE PERFORMED BY A QUALIFIED AND CERTIFIED TECHNICIAN Monthly F...

Page 41: ...KLP For MQRB4236LPT LP Conversion Millivolt 1001 P167SI 30 977 167 53 1000 P201VE Hex 1 4 1001 P201SI 0 907 201 4236RBT CKLPI For MQRB4236LPTE LP Conversion IPI 1001 P168SI 35 977 168 53 1000 P201VE H...

Page 42: ...regulator by following instructions supplied with conversion kit also See Parts B C 5 Adjust the primary air setting to the correct setting as specified in the manual or label plate To adjust air sett...

Page 43: ...e new injector is proper for the application The injector size is stamped on the side of the injector near the top LPG injectors have a groove machined around their circumference near the top while NG...

Page 44: ...Gas Conversion for Modulator PART C WARNING WARNING 44...

Page 45: ...heat silicone tempera ture resistant to 500 F 260 C apply a con tinuous bead of approximately 1 32 to all four sides of frame and insert glass with new gas ket Frame should be on flat surface with a...

Page 46: ...log 6 Place onto the mounting tab on log 2 Locate the 2 holes on the bottom of log 7 Place onto mounting tabs on log 5 STEP 5 Place glowing embers on the front of the burner tube and ember plates Pla...

Page 47: ...Pilot Shield RSP1 RSP2 Qty 1 Shield Per Kit Back View 1 2 3 4 5 6 SLOTS SLOTS SLOTS SLOTS 47...

Page 48: ...P 3 Using the platform mount access holes attach the rock platform as shown STEP 4 Fill around the rock platform with lava rock Do not place any lava rock on the burner Sprinkle vermiculite over top o...

Page 49: ...s 3 onto the burner as shown STEP 7 Place rocks 4 onto the burner as shown STEP 8 Place rocks 6 onto the burner as shown STEP 9 Place remaining rocks 4 and 6 into position as shown Finished Rock F2 Se...

Page 50: ...nt access holes attach the rock platform as shown STEP 3 Fill around the rock platform with lava rock Sprinkle vermiculite over top of the lava rock Do not place lava rock or vermiculite on top of the...

Page 51: ...own Do not place rocks directly onto the burner tubes STEP 6 Place rocks 4 into position as shown STEP 7 Place rocks 6 into position as shown STEP 8 Place remaining rocks 4 and 6 into position as show...

Page 52: ...nition can occur The following types of glass are approved Ember Glass Material from American Fireglass Maximum amount Natural Gas is 5 lbs Propane units 5 lbs Liquid Glass from Firegear Maximum amoun...

Page 53: ...KIT Optional Accent Lighting Kit See separate installation page NOTE Glass Media must be evenly spread over the Burner and False Bottom as described on last page before Rock Stones and Log Accessorie...

Page 54: ...t lamp wires through access hole in firebox as above Apply new sealant Mill Pac Secure Lamp Plate with screws Please follow the current ANSI NFPA 70 National Electrical Code in the USA and CAN CSA C22...

Page 55: ...facing upward or sideways Replace burner tube and false bottom along with pilot shield STEP 4 Connect switch wires between lamp wire and transformer see schematic Connect remaining lamp wire to trans...

Page 56: ...the remote Contrary to this feature is a Manual HI LO Control Knob The Modulating Servo Motor requires the Remote system to be present Backup Battery Pack This component permits the IPI system to oper...

Page 57: ...ol wiring harness instead of the main IPI harness From the Remote wiring harness use its male plug in connector and connect it to the female plug in in the main IPI harness Now the circuit is complete...

Page 58: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 58...

Page 59: ...anual HI LO capabilities OPTIONAL For units with remote HI LO capabilities a modulating servo is required to be installed on the valve The connectors to this servo must be connected to the Remote Harn...

Page 60: ...Configuration 3 Remote ON OFF variable HI LO and fan capabilities Refer to the fan installation removal section for fan installation 60...

Page 61: ...ent LIGHTING INSTRUCTIONS 1 STOP Read the above safety information on this label 2 Remove batteries from Receiver and or Battery Backup Pack 3 Turn off all electric power to the fireplace 4 This firep...

Page 62: ...920 5 584 PWR C Wire Harness PF2 Main Power Cord 6 1002 P12BH Battery Housing 7 1006 P921si Wire harness for Split flow 0 584 921 Not available 8 1005 P2SCH Label PF2 Schematic Decal 9 584 X12 Power V...

Page 63: ...must be followed to reset the PF2 Module Press the Red SW1 button until you hear three beeps Within 10 seconds press the SW1 button again until you hear it beep The PF2 Module may now be turned on off...

Page 64: ...Press UP on the UP DOWN Arrow Key Display will show CPI The module in the fireplace will beep once to confirm command TO RETURN TO IPI INTERMITTENT PILOT MODE Repeat steps one and two and then press...

Page 65: ...Proflame 2 Remote Control 65...

Page 66: ...Note When Smart Thermostat is activated manual flame height adjustment is disabled Note This function is only available in Room Thermostat or Smart Thermostat Control Mode 66...

Page 67: ...67...

Page 68: ...s both dwellings THIS DOES NOT APPLY to direct vent non condensing appliances in the Province of Ontario M Clearance above highest point of exit on roof 18 inches 45cm N Clearance to perpendicular wal...

Page 69: ...2 couplers to extend short pipes Single sections are preferred in an installation attaching at the fireplace and ter mination Place the spring spaces provided approximately every two feet to stabiliz...

Page 70: ...and the number of bends required 2 Having determined the vertical distance determine the maxi mum horizontal section allowed 3 Vent table has been established for 90 horizontal vertical runs With use...

Page 71: ...the 4 flex pipe as required Then attach the seven inch 7 pipe by the same method 8 Support horizontal pipes every two 2 feet 61 cm with metal strap bands Re check fireplace to make sure it is levelle...

Page 72: ...two rulers or by using a roof pitch card See figure below Slide a Roof Flashing suitable to your roof slope over the vent Place the edge of the flashing plate that will be on the higher part of the r...

Page 73: ...eep toddlers young children and other at risk individuals out of the room and away from hot surfaces Do not leave the fireplace remote control where it is accessible to children Termination Cap Safety...

Page 74: ...s are permitted however Cold Climate Switch Standing Pilot Mode must NOT be used Seven 90 elbows are possible if the total horizontal is not more than 25ft and the vertical does not exceed 15ft Refer...

Page 75: ...4 6 5 8 venting to 5 8 For Power Vent installations where flex pipe will be used up to the Power Vent unit Z47PVA Pipe Reducer 8 Sm 7 Sm Pipe Reducer 5 Sm 4 Sm Adapts PVH58 to accept 4 7 Flex Pipe On...

Page 76: ...other than in a normal residential environment c damages caused by any unauthorized alteration or repair of the unit affecting its stability or performance d damages caused by improper matching or app...

Reviews: