WARNING: If the information in these instructions is not followed
exactly, a fire or explosion may result causing property damage,
personal injury or loss of life.
Warning: Improper installation, adjustment, alteration, service or
maintenance can cause property damage, personal injury or loss of
life. Refer to this manual. Installation and service must be performed
by a qualified installer, service agency or the gas supplier.
Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
What To Do If You Smell Gas
Do not try to light any appliance.
Extinguish any open flame.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a neighbour's phone.
If you can not reach your gas supplier, call the fire department.
WARNING: The IDV33/IDV36
Fireplace Insert was designed for
installation in a solid fuel fireplace
that has been installed in
accordance with national,
provincial/state and local building
codes and is constructed of
noncombustible materials. Do not
remove any refractory materials
from any masonry solid fuel
fireplace.
The IDV33/IDV36 Fireplace Insert was
designed for installation in a zero
clearance type listed solid fuel burning
factory built fireplace. It may be
necessary to remove the damper plate,
refractory liners, log grates, glass door,
and screen rails/mesh. Removal of the
smoke baffle is necessary in most
cases.
Installation Instructions
Model Number IDV33-IDV36 Gas Fired Direct Vent Room
Heater Inserts
Model IDV33
Listed Certified for USA. and Canada
Minimum Fireplace Opening Required: 26-1/4”W x 21-3/8”H x 14-3/8”D
Certified to: ANSI Z21.88-2009, CSA 2.33-2009, CGA 2.17-M91
Model IDV36
Listed Certified for USA. and Canada
Minimum Fireplace Opening Required: 30-3/4”W x 25-5/8”H x 14-3/8”D
Certified to: ANSI Z21.88-2009, CSA 2.33-2009, CGA 2.17-M91
Printed in Canada November 6, 2009 Part # 36IDV-MAN
FOR YOUR SAFETY
Read this complete manual before beginning installation.
These instructions must be kept with the unit for future reference.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for
use with other gases, unless a certified kit is used.
A Division of R-Co. Inc.
2340 Logan Avenue
Winnipeg, Manitoba, Canada R2R 2V3
Ph: (204) 632-1962
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.