Unpacking and Setup
Inspect for shipping damage.
Examine the shipping
container immediately upon receipt. Any damage to
the container or equipment due to shipping should be
reported to the transportation company immediately.
Claims should be filed within 24 hours. Shipping
damage is not the responsibility of Prince Castle nor
its Silver King division.
1
Unpack the unit.
Take care with box cutters or other
sharp instruments not to nick the equipment when
opening the shipping container.
Carefully remove the unit from the shipping box. Be
sure to follow any orientation or caution labels on the
box.
2
Plan the unit’s location.
When locating this unit,
convenience and accessibility are important
considerations, but the following factors must be
observed:
• Proximity to a 3-prong 110 VAC receptacle for
grounding (see Step 4).
• When placing the unit on a counter, the counter
must be able to support a minimum of 100 lbs.
(45 kg).
• When placed on a counter, the unit must be on the
legs supplied. If the legs are removed, the unit will
not operate properly and the warranty will be void.
• There must be at least 4" (10.2 cm) of space above,
on the sides and behind the unit and open in front.
• Correct serving height is important so that it can be
operated properly.
• The unit must be level. The legs are adjustable to
aid in leveling the unit.
• Avoid placing the unit next to an oven, heating
element or hot air source which would affect the
performance of the unit.
3
Meet electrical requirements.
Prior to connecting the
unit to power, be sure to check the data plate located
on the end panel of the cabinet for required voltage.
The specifications on the data plate supersede any
information contained in this manual.
The standard unit is equipped with a seven (7) foot
power cord that requires a 115 Volt, 60 Cycle, 1
Phase, properly grounded electrical receptacle,
protected with a 15 or 20 ampere fuse or breaker.
The power cord comes with a 3-prong plug for
grounding purposes. Any attempt to cut off this
grounding spike or to connect to an ungrounded
adapter plug could result in serious injury, will
void the warranty and terminates the
manufacturer’s responsibility.
WARNING