SECTION VII. TROUBLE SHOOTING GUIDE
Problem
Possible Cause
Solution
Open Valve or unclog.
Replace filters.
Feed Water pressure must be above
40 psig.
See Feed Water operating limits.
Correct cause of fouling, replace
Membrane.
Empty water from Holding Tank,
and with the faucet open, adjust air
pressure to 5–7 psig (35–48 kPa) range.
Replace tank.
Open Valve.
Clear or replace Drain Restrictor.
Clear or replace the Air Gap Faucet.
Free check.
Replace ASO Valve components.
Replace Post Filter.
Empty water from Holding Tank and
with the faucet open, adjust the air
pressure to 5–7 psig (35–48 kPa) range.
Check for leakage at the Air Valve Stem.
Open Valve.
Repair or replace Dispensing Faucet.
Allow Holding Tank to refill (adding
a second Holding Tank will increase
storage capacity).
See Low Quantity of Product Water
from Holding Tank section above.
Replace Filter.
Feed Water Pressure must be above
40 psig.
Check Feed Water Saddle Valve.
Check O–ring.
Check the brine seal.
If Membrane life is unusually short,
find and correct the problem.
Replace Membrane.
Feed Water Saddle Valve is plugged or
closed.
Clogged Sediment/Carbon Prefilter or
Activated Carbon Post Filter.
Low water pressure.
R.O. Membrane is fouled.
Air precharge pressure in Holding
Tank is too high.
Air precharge is too low
Air bladder in the Holding Tank is
ruptured.
Holding Tank Valve is closed.
No drain flow, the Drain Restrictor
is plugged.
No drain flow, the drain orifice in the Air
Gap Faucet is plugged.
The Check Valve is stuck.
The ASO Valve is malfunctioning.
Activated Carbon Post Filter is plugged.
Air precharge in the Holding Tank is
too low.
Holding Tank Valve is partially closed.
The dispensing Faucet is out of
adjustment or faulty.
Heavy water use, Holding Tank is deplet-
ed.
Low Water Production.
Clogged Sediment/Carbon Prefilter.
Low Water Pressure.
R.O. Membrane O–ring is crimped.
R.O. Membrane brine seal is not sealing
up into the manifold head.
R.O. Membrane is expended.
Low quantity of Product Water
from Holding Tank
Low pressure at the Dispensing
Faucet
High Total Dissolved Solids (TDS) in
the Product Water