MGTE 1-1/2” METERED & TIMECLOCK
OPERATION
8
Phone: (262) 681-1300 • Web: www.Marlo-Inc.com • E-mail: [email protected]
INSTALLER DISPLAY SETTINGS
“MGTE” Series Automatic Water Conditioners
6
8-192 R1
Installer Display Settings
STEP 1I
- Press NEXT and UP simultaneously for 3 seconds.
STEP 2I
–
Hardness:
The default is 20 with value ranges from 1 to 150 in 1
grain increments. Note: The grains per gallon can be increased if soluble iron
needs to be reduced.
Set the amount of hardness in grains of hardness as calcium carbonate per
gallon using DOWN or UP.
This display will not show if ‘AUTO’ is not selected in Set Volume Capacity in
OEM Softener System Setup. Press NEXT to go to step 3I. Press REGEN to
exit Installer Display Settings.
STEP 3I
–
Day Override:
Number of days between regeneration (1 to 28); or
“OFF”.
If value set to “OFF”, regeneration initiation is based solely on volume used. If
value is set as a number (allowable range from 1 to 28) a regeneration
initiation will be called for on that day even if sufficient volume of water were
not used to call for a regeneration. Set Day Override using DOWN or UP.
When volume capacity is set to “OFF” (time clock), sets the number of days
between regenerations. When volume capacity is set to AUTO or to a number
(metered), sets the maximum number of days between regenerations. See
Setting Options Table 8 for more detail on setup. Press NEXT to go to step 4I.
Press REGEN to return to previous step.
STEP 4I
–
Next Regeneration Time (hour):
The default time is 2:00 AM.
AM/PM toggles after 12.
Used for DELAY regeneration. Set the “hour” of day for regeneration using
DOWN or UP. If “IMMEDIATE” is selected in Set Regeneration Time Option in
OEM Softener System Setup, this display will show “REGEN IMMEDIATE ON
ZERO GAL”. Press NEXT to go to step 5I. Press REGEN to return to previous
step.
STEP 5I
–
Next Regeneration Time (minutes):
Used for DELAY regeneration. Set the “minutes” of day for regeneration using
DOWN or UP. This display will not be shown if “IMMEDIATE” is selected in
Set Regeneration Time Option in OEM Softener System Setup. Press NEXT
to go to Step 6I. Press REGEN to return to previous step.