17. The unit must sit for 24 to 48 hours before a complete regeneration should occur. This gives the media time to
saturate. Insufficient saturation time will cause media to be lost to drain.
FAILURE TO FOLLOW PROPER
START-UP INSTRUCTIONS WILL RESULT IN EQUIPMENT MALFUNCTION NOT COVERED
UNDER WARRANTY.
20. Open the nearest cold water faucet.
21. Allow water to run until clear and excess air has been purged from the line.
22. Close faucet.
23. If you have placed the water softener in bypass, return the softener to the Service position.
24. Open shut off valve to the water heater.
25. Verify the regeneration times. See step 1 below.
26. Set time of day. See page 5 & 6.
BACKWASHING
The Filter Vessel (Tank #2) must independently Backwash prior to the Oxidizer Vessel (Tank #1). It is
important to stagger the Backwash start time for each Vessel. If there is a water softener system present, it is
important to not only schedule staggered backwashing times of the filters, but also at different times than the softener’s
scheduled backwashing time. The Klear-Flo II units are preset to have staggered backwash times. These backwash times
are recommended because most water residential water supplies do not produce sufficient flow and pressure to backwash
both Vessels simultaneously.
1. FILTER VESSEL SETTINGS -
Follow the procedure below to set the filter vessel regeneration time & frequency.
A. On the filter vessel, press the NEXT and UP arrow keys simultaniously for three to five seconds. The screen
will show -nA-. Press the NEXT key.
B. The filter comes pre-programmed for 3 days. Changes can be made later if different backwash cycle intervals
are required.
C. Once days between regeneration has been selected press the NEXT key.
D. Time of Regeneration screen. The unit comes preset at 1 AM. To change the time, use the UP or DOWN arrow
keys. Make sure to note AM or PM. Press NEXT to set minutes. Press NEXT to return to home screen.
2. OXIDIZER VESSEL SETTINGS -
Follow the procedure below to set the oxidizer vessel:
A. On the oxidizer vessel, press the NEXT and UP arrow keys simultaniously for three to five seconds. The
screen will show -nA-. Press the NEXT key.
B. Set the
Days to Regenerate
. The Oxidizer Vessel is capable of treating 1,000 gallons per
regeneration. Daily water usage will determine the regeneration frequency. Select one
recommended regeneration schedule from the following table:
• Recharge every 3 days - ( 1-2 people per family or 200 gallon/day water usage)
• Recharge every 2 days - (3-4 people per family or 400 gallon/day water usage)
• Recharge every day - (5 or more people per family or 1000 gallon/day water usage.)
Changes can be made later if different Backwash cycle intervals are required.
C. Once days between regeneration has been selected press the NEXT key.
D. Time of Regeneration screen. The unit comes preset at 12 AM. To change the time, use the UP or DOWN
arrow keys. Make sure to note AM or PM. Press NEXT to set minutes. Press NEXT to return to home screen.
IMPORTANT: UNITS ARE PRE-PROGRAMMED TO HAVE STAGGERED BACKWASH TIMES. IF YOU CHOOSE TO
RE-PROGRAM, PLEASE REMEMBER TO SET STAGGERED BACKWASH TIMES.
WATER SOFTENER NOTE:
The Klear-Flo Filter System is compatible with most automatic Water Softeners. The
Softener will performn best when installed
after
the Klear-Flo Filter System. The regeneration schedule of the
water softener must be set to start
3 hours before or 2 hours after
the Klear-Flo start time. This will assure that
sufficient water volume and drain capacity is available for the regeneration process of each unit.