1
Oxidizer
Tank
Assembly rear view
Filter
Tank
Assembly rear view
Sanitary Drain, Floor Drain or Laundry
Tubs are acceptable.
Do not make a direct connection to the drain.
An air gap must
be present.
Cold hard water inlet 30 p.s.i. minimum pressure 1/2” minimum pipe size
Maximum drain pipe elevation above drain port is 5 ft.
High Pressure W
arning:
If feedwater pressure is known to be above 100 p.s.i. it is strongly recommended that a pressure reducing valve be installed at this point. Set at 80 p.s.i.
Hard water to Sprinklers and any desired unsoftened fixtures
Treated W
ater Outlet
Manual Inlet V
alve
(optional) (Required in some States)
110-125 V
olt
Continuous Power Supply
Manual Bypass V
alve
(Normally Closed) (optional)
Drain line 1/2” diameter minimum size
Connection to sanitary sewer line (optional)
Air gap device
Sanitary sewer line
Drain
Trap
By-Pass V
alve
6 inches Minimum Air
Trap
Below V
alve Inlet
NOTE 1
Piping must extend at least 6 inches below the V
alve Inlet
creating an air trap.
Klear Flo II Installation Diagram
5-251
SEE NOTE 1
By-Pass V
alve
To Drain
Drain Port
Drain Port