Marley CSLAL Installation, Operation & Maintenance Instructions Manual Download Page 1

WARNING

SAVE THESE INSTRUCTIONS

WHEN USING ELECTRICAL APPLIANCES, BASIC PRECAU-
TIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE
THE RISK OF FIRE, ELECTRIC SHOCK, AND INJURY TO
PERSONS, INCLUDING THE FOLLOWING:

1. Read all instructions before installing or using the heater.

2. A heater has hot and arcing or sparking parts inside.  Do not

use in areas where gasoline or flammable liquids are used
or stored. Do not use in corrosive environment or any area
where explosive materials are used or stored.

3. This heater is hot when in use.  To avoid burns, do not let

bare skin touch hot surfaces.  Keep combustible materials,
such as furniture, pillows, bedding, papers, clothes, and cur-

tains away from heater.

4. To  prevent  a  possible  fire,  do  not  block  air  intakes  or

exhaust in any manner.

5. Do not insert or allow foreign objects to enter any ventilation

or exhaust opening as this may cause an electric shock, fire,
or damage the heater.

6. Serious  injury  or  death  could  result  from  electric  shock.

Make sure electrical power supply circuit coming to heater
is disconnected at main disconnect or service panel before
installing or servicing this heater.

7. This  heater  is  not  for  residential  or  household  use,  except

model CSLAS @ 250 watts per foot.

Type CSL 

Commercial Sill Height

Convectors

Commercial
Sill Height Convection Heaters 
(Type CSL)

!

Installation, Operation & Maintenance Instructions

IMPORTANT INSTRUCTIONS

RECEIVING

Material when shipped was in good order and Marley
Engineered Products holds clear bill of lading, therefore any
concealed damage must be reported at once to the carrier for
inspection and settlement.

Note: It is advisable to store cartons in a central area to be
drawn upon as needed per room requirements.  If called for on
order, the cartons will have been tagged with proper room 
number.

General

This heater is designed to provide years of efficient, trouble free operation as a primary or supplemental heat source for comfort
heating in residential (Model CSLAS, 250 watt max only) and commercial applications.  Installation or use of this product in any
manner not described within this manual will void the warranty and could result in injury, damage to property, or permanent damage
to heater.

Summary of Contents for CSLAL

Page 1: ...ower supply circuit coming to heater is disconnected at main disconnect or service panel before installing or servicing this heater 7 This heater is not for residential or household use except model C...

Page 2: ...V 277V Number L Watts Ft Watts 1 3 1 3 1 2125 125 250 1 2 1 0 0 9 2188 188 375 1 8 1 6 1 4 2250 250 500 2 4 2 1 1 8 2375 28 375 750 3 6 3 1 2 7 2500 500 1000 4 8 4 2 3 6 2564 564 1125 5 4 3 1 4 7 2 7...

Page 3: ...an electrical convenience receptacle outlet CAUTION Heater operates at high temperatures Keep elec trical cords including telephone and computer cables drapes and other furnishings away from heater F...

Page 4: ...locations remove the filler section and drill the required mounting holes Install the filler section in the heater and the end cap on the filler section as shown in Figure 3 Note If a thermostat and...

Page 5: ...with corner section Refer to Figure 6 6 Install end caps 6 on the outer end of the last heater 7 and 9 using four 6 screws supplied with end caps Refer to Figure 5 for details of end cap installation...

Page 6: ...e accumulated inside heater around element fins If heater must be disassembled for cleaning use care when cleaning element fins to avoid damaging fins 4 After cleaning and servicing always reassemble...

Page 7: ...060 066 072 077 081 277 Volts 049 055 061 067 073 078 082 188 W ft 120 Volts 005 011 017 023 029 per 208 Volts 002 008 014 020 026 032 036 Element 240 Volts 001 007 013 019 025 031 035 277 Volts 000 0...

Page 8: ...y not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state For the address of your nearest authorized service center contact Mar...

Page 9: ...o de alimentaci n el c trica del calefactor est desconectado en el tablero de ser vicio o desconectador principal antes de instalar o prestar servicio a este calefactor 7 Este calefactor no es para us...

Page 10: ...5 2 4 5 10188 10 188 1875 9 0 7 8 6 7 10250 250 2500 12 0 10 4 9 0 Modelo CSLAS H 5 1 2 D 3 Tabla A Tabla A continuaci n Corriente A N mero de Longitud Watts 208 V 240 V 277 V cat logo L Watts pie tot...

Page 11: ...onan con los juegos 6 No instale el calefactor debajo de un tomacorriente el ctrico PRECAUCI N el calefactor funciona a altas temperaturas Mantenga los cordones el ctricos incluidos los cables de tel...

Page 12: ...tir el acceso a estos controles Figura 3 5 Coloque el gabinete del calefactor en la pared para verificar la uni formidad de la misma No lleve el calefactor contra una superficie de pared que sea irreg...

Page 13: ...la instalaci n de las tapas extremas consulte la Figura 5 7 Perfore los agujeros de montaje del tama o requerido en todos los gabinetes de los calefactores Nota en cada caja de conexiones se proporcio...

Page 14: ...cionando correcta mente Nota importante existen dispositivos de seguridad incorporados que se suministran dentro de los calefactores incluidos uno o m s controles de l mite de sobretemperatura protect...

Page 15: ...5 096 elemento 240 volts 048 054 060 066 072 077 081 277 volts 049 055 061 067 073 078 082 188 W pie 120 volts 005 011 017 023 029 por 208 volts 002 008 014 020 026 032 036 elemento 240 volts 001 007...

Page 16: ...rse a su caso Esta garant a le da derechos legales espec ficos y usted puede tener tambi n otros derechos que var an de un esta do o jurisdicci n a otro Para obtener la direcci n de su centro de servi...

Page 17: ...voire mortelle peut r sulter d une commotion lectrique Assurez vous que le circuit du secteur d alimentation lectrique arrivant au radiateur est bien d branch en amont l interrupteur g n ral ou au pan...

Page 18: ...d le CSLAS H 5 1 2 D 3 Tableau A Tableau A suite Amp rage N du longueur Total en 208 V 240 V 277 V catalogue L Watts pied Watts 1 3 1 3 1 2125 125 250 1 2 1 0 0 9 2188 188 375 1 8 1 6 1 4 2250 250 500...

Page 19: ...g es par le feu il faut utiliser des kits d espacement de cat gorie de r f rence S01 ou S02 Consultez les instructions livr es avec ces kits 6 N utilisez pas le radiateur sous une prise d alimentation...

Page 20: ...arter pour supporter le poids des radiateurs de grande longueur 6 et plus Ne percez aucun trou de montage additionnel dans les bo tiers de raccordement 5 Positionnez le carter du radiateur sur le mur...

Page 21: ...s d extr mit 6 sur le bout ext rieur du dernier radiateur 7 et 9 au moyen de quatre vis 6 fournies avec ces capuchons d extr mit R f rez vous la Figure 5 pour les d tails d installation de ces capucho...

Page 22: ...nt des unit s Remarque importante Il y a des dispositifs de s curit int gr s dans les radiateurs incluant un ou plusieurs contr les de d passement de limite de temp rature protection thermique consult...

Page 23: ...r 208 Volts 086 088 090 092 094 095 096 l ment 240 Volts 048 054 060 066 072 077 081 277 Volts 049 055 061 067 073 078 082 188 W pied 120 Volts 005 011 017 023 029 par 208 Volts 002 008 014 020 026 03...

Page 24: ...st possible que les exclusions et restrictions ci dessus ne s ap pliquent pas vous Cette garantie vous accorde des droits juridiques sp cifiques mais il est possible que vous ayez galement d autres dr...