MOUNTING DIMENSIONS

35

CONTROL

COMPARTMENT

TOP

16-1/4

13-1/2

18

5

3

4-3/8

26-3/8

13

14-1/2

OPTIONAL

9-7/8

4-1/2(114 mm)

1-3/8

3/4 (19 mm)

OUTSIDE AIR

8-7/16

FRONT VIEW

CONTROL

COMPARTMENT

27

OPTIONAL

14-3/8

28

45

TOP

COMPARTMENT

CONTROL

FRONT VIEW

OPTIONAL

41

41

58

TOP

FRONT VIEW

41

OPTIONAL

68

CONTROL

COMPARTMENT

TOP

25-1/2

OPTIONAL

FRONT VIEW

55

32-5/8

78

TOP

CONTROL

28-1/2

COMPARTMENT

Collar

OPTIONAL

Heater Back

OUTSIDE AIR

FRONT VIEW

LEFT SIDE VIEW

Concentric Knockouts

1-23/32", 1-23/64", 1-31/32"

7/8", 1-3/32"
Concentric Knockouts

Typical All Heaters

Knockout Size & Location

NOTE:

8-7/16

OUTSIDE AIR

13-1/2

16-1/4

8-7/16

OUTSIDE AIR

14-3/8

13-1/2

16-1/4

13-1/2

8-7/16

16-1/4

14-3/8

OUTSIDE AIR

25-1/2

13-1/2

14-3/8

OUTSIDE AIR

8-7/16

16-1/4

RIGHT SIDE VIEW

Front Cover

3

4

Drill location for conduit hole

BOTTOM VIEW

1-5/8

7

Drill location for conduit hole

(670 mm)

(251 mm)

(214 mm)

(889 mm)

(457 mm)

(343 mm)

(413 mm)

(35 mm)

(330 mm)

(368 mm)

(111 mm)

(76mm)

(127 mm)

(76 mm)

(102 mm)

(41 mm)

(178 mm)

(1143 mm)

(343 mm)

(711 mm)

(413 mm)

(365 mm)

(686 mm)

(214 mm)

(343 mm)

(1041 mm)

(1473 mm)

(365 mm)

(1041 mm)

(214 mm)

(413 mm)

(343 mm)

(648 mm)

(648 mm)

(1727 mm)

(413 mm)

(214 mm)

(1041 mm)

(365 mm)

(343 mm)

(724 mm)

(829 mm)

(1981 mm)

(214 mm)

(413 mm)

(1397 mm)

(365 mm)

Figure 2

Air Flow --->

Air Flow --->

Air Flow --->

Air Flow --->

Including Front Cover

(Typ. all lengths)

(Typ. all lengths)

(Typ. all lengths)

35" (889 mm) CABINET

45" (1143 mm) CABINET

58" (1473 mm) CABINET

68" (1727 mm) CABINET

78" (1981 mm) CABINET

Figure 2

6

Summary of Contents for 935

Page 1: ... and the heater must be ground ed 3 Verify the power supply voltage coming to heater matches the ratings printed on the heater nameplate before energizing 4 This heater is hot when in use To avoid burns do not let bare skin touch hot surfaces 5 Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause electric shock fire or damage to heater 6 Do not block...

Page 2: ...68 26 34 43 51 59 68 27 39 52 64 77 89 n a 36 52 69 86 n a n a n a 240 3 ph 60 Hz 6 8 10 13 15 18 20 11 16 20 25 30 35 40 16 20 25 30 35 40 16 24 31 38 45 52 60 21 31 41 50 60 70 79 277 1 ph 60 Hz 8 12 15 19 22 26 30 16 23 30 37 44 52 59 23 30 37 44 52 59 24 34 45 56 67 78 n a 31 46 60 74 n a n a n a 347 1 ph 60 Hz 7 9 12 15 18 21 24 13 18 24 30 36 41 47 18 24 30 36 41 47 19 28 36 45 n a n a n a 2...

Page 3: ...e If the heater was 68 inches long the opening should measure 26 5 8 high x 68 1 4 long 2 The depth of the recess will vary with the desired amount of heater recess 3 Proceed to HEATER INSTALLATION section INSTALLATION OF OPTIONAL 900 SERIES RECESS TRIM KIT 1 Determine depth of heater recess 2 Align recess trim frame so that the trim frame front edge will touch wall when heater is installed 3 Matc...

Page 4: ...n of damper opening 3 Position the top flange bracket with the flange at the top of the damper opening and holes in the flange align with holes in the cabinet back 4 Attach flange to cabinet with screws provided 5 Position and attach remaining three 3 flange brackets around damper opening 6 Position field ductwork to outside of flange brackets 7 Mark and drill starting holes in duct and flange 8 I...

Page 5: ...ll Wall Wall Wall End mounting 24 min 610 mm Zero or greater End mounting semi recess 24 min 610 mm Zero or greater End mounting full recess Zero or greater Ceiling Floor End mounting Zero or greater End mounting semi recess End mounting full recess Wall Wall Wall Wall Wall Wall Wall Ceiling Floor Wall Ceiling Floor Wall Zero or greater Zero or greater Zero or greater Zero or greater Downflow Upfl...

Page 6: ... 16 1 4 8 7 16 OUTSIDE AIR 14 3 8 13 1 2 16 1 4 13 1 2 8 7 16 16 1 4 14 3 8 OUTSIDE AIR 25 1 2 13 1 2 14 3 8 OUTSIDE AIR 8 7 16 16 1 4 RIGHT SIDE VIEW Front Cover 3 4 Drill location for conduit hole BOTTOM VIEW 1 5 8 7 Drill location for conduit hole 670 mm 251 mm 214 mm 889 mm 457 mm 343 mm 413 mm 35 mm 330 mm 368 mm 111 mm 7 6 m m 127 mm 76 mm 102 mm 41 mm 178 mm 1143 mm 343 mm 711 mm 413 mm 365...

Page 7: ... FRONT DISCHARGE 543 mm 21 3 8 6 13 16 173 mm 173 mm 6 13 16 35 889 mm CABINET 21 3 8 173 mm 6 13 16 543 mm 6 13 16 173 mm 4 5 8 118 mm 35 3 4 908 mm 118 mm 4 5 8 35 3 4 4 5 8 908 mm 4 5 8 118 mm 118 mm FRONT VIEW 45 1143 mm CABINET 43 3 8 1102 mm 7 5 16 186 mm 186 mm 7 5 16 7 5 16 186 mm 45 3 8 1102 mm 186 mm 7 5 16 58 1473 mm CABINET FRONT VIEW 68 1727 mm CABINET FRONT VIEW 3 5 8 92 mm 60 3 4 15...

Page 8: ... 1 E1 1 R1 1 C A E1 3 R1 2 E1 2 AL1 2 B C A R2 1 F2 F1 M FDR 1 S1 2 L H FAOR 1 T 4 FAOS FAOR C 1 C 4 T 1 T 2 H L T C S1 1 ORANGE RFHS EMS R 1 FDR R2 MR1 S2 C DM SW DAMPER MOTOR CONTROLLER OPTIONAL 100 OUTSIDE AIR DAMPER CLOSED OPEN S3 NSB 1 T5 T6 24 VAC EXTERNAL NIGHT SETBACK CIRCUIT RS MUST BE ENERGIZED FOR DAY OPERATION BLUE C 3 C 2 EMS ENERGY MANAGEMENT SYSTEM TIE IN CONTACTS MUST BE CLOSED FOR...

Page 9: ...010 1 059 8 1 048 1 053 1 047 1 053 1 027 1 021 1 011 1 010 1 059 58 in 10 1 049 1 055 1 048 1 054 1 027 1 021 1 011 1 010 1 059 12 2 046 1 056 2 045 1 055 1 007 1 023 1 012 1 011 1 060 14 2 046 1 057 2 045 1 056 1 021 1 068 1 013 1 012 1 060 16 2 048 1 058 2 047 1 057 1 022 1 068 1 014 1 013 1 061 6 1 046 1 052 1 045 1 052 1 026 1 019 1 010 1 010 1 059 9 1 049 1 054 1 048 1 053 1 028 1 021 1 011 ...

Page 10: ... 2 104 2 105 2 107 2 104 2 105 8 2 106 2 106 2 107 2 107 2 108 2 109 2 106 2 108 2 109 58 in 10 2 110 2 110 2 111 2 111 2 112 2 113 2 110 2 112 2 113 12 4 107 4 107 4 108 4 108 4 104 4 105 4 107 4 104 4 105 14 2 107 2 107 2 108 2 108 2 104 2 105 2 107 2 104 2 105 2 106 2 106 2 107 2 107 2 108 2 109 2 106 2 108 2 109 16 2 107 2 107 2 108 2 108 2 104 2 105 2 107 2 104 2 105 2 110 2 110 2 111 2 111 2...

Page 11: ...1 4520 17 002 Auto Reset Limit 4520 2048 000 Power Relay 24V Control 410101001 120V Control 410101003 Fan Delay Relay Single Stage Heater 24V Control 410171001 120V Control 410171002 Two Stage Heater 24V Control 410101001 120V Control 410101003 Transformer Power 277V Heater 490015025 490015024 347V Heater 490015026 490015027 380V Heater 490015011 490015023 480V Heater 490015025 490015024 600V Heat...

Page 12: ...TIES EXPRESSED OR IMPLIED AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS AGREEMENT MARLEY ENGINEERED PRODUCTS SHALL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES ARISING WITH RESPECT TO THE PRODUCT WHETHER BASED UPON NEGLIGENCE TORT STRICT LIABILITY OR CONTRACT Some states do ...

Reviews: