LIMITED WARRANTY

All products manufactured by Marley Engineered Products are warranted against defects in workmanship and materials for one
year from date of installation, except heating elements which are warranted against defects in workmanship and materials for
five years from date of installation. This warranty does not apply to damage from accident, misuse, or alteration; nor where the
connected voltage is more than 5% above the nameplate voltage; nor to equipment improperly installed or wired or maintained
in violation of the product’s installation instructions. All claims for warranty work must be accompanied by proof of the date of
installation.

The customer shall be responsible for all costs incurred in the removal or reinstallation of products, including labor costs, and
shipping costs incurred to return products to Marley Engineered Products Service Center. Within the limitations of this warranty,
inoperative units should be returned to the nearest Marley authorized service center or the Marley Engineered Products Center,
and we will repair or replace, at our option, at no charge to you with return freight paid by Marley. It is agreed that such repair or
replacement is the exclusive remedy available from Marley Engineered Products.

THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, AND ALL IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID
EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS AGREEMENT. MARLEY
ENGINEERED PRODUCTS SHALL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES ARISING WITH RESPECT TO THE
PRODUCT, WHETHER BASED UPON NEGLIGENCE, TORT, STRICT LIABILITY, OR CONTRACT.

Some states do  not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion or limita-
tion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state
to state.

For the address of your nearest authorized service center, contact Marley Engineered Products in Bennettsville, SC, at 1-800-
642-4328. Merchandise returned to the factory must be accompanied by a return authorization and service identification tag, both
available from Marley Engineered Products. When requesting return authorization, include all catalog numbers shown on the
products.

HOW TO ORDER REPAIR PARTS

In order to obtain any needed repair or replacement parts, warranty service or

technical information, please contact Marley Engineered Products Service Center
toll-free by calling  1-800-642-HEAT. 

When ordering repair parts, always give the information listed as follows:

1. The Part Number 

3. The Part Description

2. The Model Number 4. Date of Manufacture

5/01

5200-2386-001

ECR 34345

12

SPX Corporation
470 Beauty Spot Rd. East
Bennettsville, SC  29512 USA

Summary of Contents for 935

Page 1: ... and the heater must be ground ed 3 Verify the power supply voltage coming to heater matches the ratings printed on the heater nameplate before energizing 4 This heater is hot when in use To avoid burns do not let bare skin touch hot surfaces 5 Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause electric shock fire or damage to heater 6 Do not block...

Page 2: ...68 26 34 43 51 59 68 27 39 52 64 77 89 n a 36 52 69 86 n a n a n a 240 3 ph 60 Hz 6 8 10 13 15 18 20 11 16 20 25 30 35 40 16 20 25 30 35 40 16 24 31 38 45 52 60 21 31 41 50 60 70 79 277 1 ph 60 Hz 8 12 15 19 22 26 30 16 23 30 37 44 52 59 23 30 37 44 52 59 24 34 45 56 67 78 n a 31 46 60 74 n a n a n a 347 1 ph 60 Hz 7 9 12 15 18 21 24 13 18 24 30 36 41 47 18 24 30 36 41 47 19 28 36 45 n a n a n a 2...

Page 3: ...e If the heater was 68 inches long the opening should measure 26 5 8 high x 68 1 4 long 2 The depth of the recess will vary with the desired amount of heater recess 3 Proceed to HEATER INSTALLATION section INSTALLATION OF OPTIONAL 900 SERIES RECESS TRIM KIT 1 Determine depth of heater recess 2 Align recess trim frame so that the trim frame front edge will touch wall when heater is installed 3 Matc...

Page 4: ...n of damper opening 3 Position the top flange bracket with the flange at the top of the damper opening and holes in the flange align with holes in the cabinet back 4 Attach flange to cabinet with screws provided 5 Position and attach remaining three 3 flange brackets around damper opening 6 Position field ductwork to outside of flange brackets 7 Mark and drill starting holes in duct and flange 8 I...

Page 5: ...ll Wall Wall Wall End mounting 24 min 610 mm Zero or greater End mounting semi recess 24 min 610 mm Zero or greater End mounting full recess Zero or greater Ceiling Floor End mounting Zero or greater End mounting semi recess End mounting full recess Wall Wall Wall Wall Wall Wall Wall Ceiling Floor Wall Ceiling Floor Wall Zero or greater Zero or greater Zero or greater Zero or greater Downflow Upfl...

Page 6: ... 16 1 4 8 7 16 OUTSIDE AIR 14 3 8 13 1 2 16 1 4 13 1 2 8 7 16 16 1 4 14 3 8 OUTSIDE AIR 25 1 2 13 1 2 14 3 8 OUTSIDE AIR 8 7 16 16 1 4 RIGHT SIDE VIEW Front Cover 3 4 Drill location for conduit hole BOTTOM VIEW 1 5 8 7 Drill location for conduit hole 670 mm 251 mm 214 mm 889 mm 457 mm 343 mm 413 mm 35 mm 330 mm 368 mm 111 mm 7 6 m m 127 mm 76 mm 102 mm 41 mm 178 mm 1143 mm 343 mm 711 mm 413 mm 365...

Page 7: ... FRONT DISCHARGE 543 mm 21 3 8 6 13 16 173 mm 173 mm 6 13 16 35 889 mm CABINET 21 3 8 173 mm 6 13 16 543 mm 6 13 16 173 mm 4 5 8 118 mm 35 3 4 908 mm 118 mm 4 5 8 35 3 4 4 5 8 908 mm 4 5 8 118 mm 118 mm FRONT VIEW 45 1143 mm CABINET 43 3 8 1102 mm 7 5 16 186 mm 186 mm 7 5 16 7 5 16 186 mm 45 3 8 1102 mm 186 mm 7 5 16 58 1473 mm CABINET FRONT VIEW 68 1727 mm CABINET FRONT VIEW 3 5 8 92 mm 60 3 4 15...

Page 8: ... 1 E1 1 R1 1 C A E1 3 R1 2 E1 2 AL1 2 B C A R2 1 F2 F1 M FDR 1 S1 2 L H FAOR 1 T 4 FAOS FAOR C 1 C 4 T 1 T 2 H L T C S1 1 ORANGE RFHS EMS R 1 FDR R2 MR1 S2 C DM SW DAMPER MOTOR CONTROLLER OPTIONAL 100 OUTSIDE AIR DAMPER CLOSED OPEN S3 NSB 1 T5 T6 24 VAC EXTERNAL NIGHT SETBACK CIRCUIT RS MUST BE ENERGIZED FOR DAY OPERATION BLUE C 3 C 2 EMS ENERGY MANAGEMENT SYSTEM TIE IN CONTACTS MUST BE CLOSED FOR...

Page 9: ...010 1 059 8 1 048 1 053 1 047 1 053 1 027 1 021 1 011 1 010 1 059 58 in 10 1 049 1 055 1 048 1 054 1 027 1 021 1 011 1 010 1 059 12 2 046 1 056 2 045 1 055 1 007 1 023 1 012 1 011 1 060 14 2 046 1 057 2 045 1 056 1 021 1 068 1 013 1 012 1 060 16 2 048 1 058 2 047 1 057 1 022 1 068 1 014 1 013 1 061 6 1 046 1 052 1 045 1 052 1 026 1 019 1 010 1 010 1 059 9 1 049 1 054 1 048 1 053 1 028 1 021 1 011 ...

Page 10: ... 2 104 2 105 2 107 2 104 2 105 8 2 106 2 106 2 107 2 107 2 108 2 109 2 106 2 108 2 109 58 in 10 2 110 2 110 2 111 2 111 2 112 2 113 2 110 2 112 2 113 12 4 107 4 107 4 108 4 108 4 104 4 105 4 107 4 104 4 105 14 2 107 2 107 2 108 2 108 2 104 2 105 2 107 2 104 2 105 2 106 2 106 2 107 2 107 2 108 2 109 2 106 2 108 2 109 16 2 107 2 107 2 108 2 108 2 104 2 105 2 107 2 104 2 105 2 110 2 110 2 111 2 111 2...

Page 11: ...1 4520 17 002 Auto Reset Limit 4520 2048 000 Power Relay 24V Control 410101001 120V Control 410101003 Fan Delay Relay Single Stage Heater 24V Control 410171001 120V Control 410171002 Two Stage Heater 24V Control 410101001 120V Control 410101003 Transformer Power 277V Heater 490015025 490015024 347V Heater 490015026 490015027 380V Heater 490015011 490015023 480V Heater 490015025 490015024 600V Heat...

Page 12: ...TIES EXPRESSED OR IMPLIED AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS AGREEMENT MARLEY ENGINEERED PRODUCTS SHALL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES ARISING WITH RESPECT TO THE PRODUCT WHETHER BASED UPON NEGLIGENCE TORT STRICT LIABILITY OR CONTRACT Some states do ...

Reviews: