background image

5. Loosen screw in built-in cable clamp (Figure 4) or remove

desired knockout from heater wiring compartment. Install
power cable into wiring compartment allowing at least 6 in
(153mm) of cable for connection to heater. To install two
power cables using the built-in cable clamp, bend tab cover-
ing second hole up and back to rear wall of wiring compart-
ment.  If built-in cable clamp is not used, install approved
cable restraint (not included ) in desired knockout.

N

NOTE: cross stamped mounting perforations are provided in
back of heater enclosure above heating element at mounting
screw locations, see Figure 4.  

6. Position heater at desired location and attach to wall using

wood screws or appropriate hardware.  Locate studs and
drive screws into studs where possible.  For heaters up to 6
feet (1.8 m) in length, one screw at each end is adequate.
For longer units, an additional screw in center is required.
Tighten screws and then loosen screws at least ¼ turn to
allow heater to expand and contract during use.  If unit is
mounted above floor, two additional mounting holes are pro-
vided at each end below the heating element (see Figure 4).
Install an additional screw at each end for stability making
sure to loosen each screw at least ¼ turn.

7. Connect the supply cable grounding wire to the bare copper

pigtail in wiring compartment.

8. Follow the desired wiring diagram, as shown in Figure 5, to

connect the power supply to the heater using approved wire
nuts.

NOTE: When accessories are installed, use wiring diagram 
supplied with the accessory.

9. If front cover was removed, reinstall by hooking the top edge

on the support bracket(s).  Then push down to latch onto the
support bracket(s).

10.Replace wiring compartment cover(s).

11.Follow instructions accompanying thermostat for installation

and wiring thermostat.  Visit www.marleymep.com for typical
thermostat wiring diagrams.

OPERATING INSTRUCTIONS

1. This heater must be properly installed before it is used.

2. After the baseboard system has been completely installed,

all thermostats should be turned to LOW or NO HEAT.  
Turn on breakers, wait 3 to 5 minutes and check to see that
none of the heaters are operating.  If operating, disconnect
power and check wiring.  If none are operating then turn
thermostats to highest position and wait 3 to 5 minutes.
Check to see that all heater(s) are operating.  Should any not
be operating, disconnect power and check wiring. 

3. Allow entire system to operate steadily for 1/2 hour.  This 

should remove oily residue from manufacturing.  (Some 
smoking may occur).

4. Select the setting for comfort on all thermostats.

5. A safety limit control is provided to turn off the heater auto-

matically if it is blocked or otherwise overheats due to an
abnormal condition-see Figures 4 and 5. DO NOT bypass or
remove this safety device from the electrical circuit-see
Warning 11 on page 2. During normal use, this safety control
should not operate. If you find that this control is operating,
make sure the heater is not being blocked. If it continues to
cycle the heater off, disconnect power to heater and have it
checked and repaired by a qualified electrician.

MAINTENANCE INSTRUCTIONS

Your heater will give you years of service and comfort with only
minimum care.  To assure efficient operation follow the simple
instructions below.

1. The user can perform some basic cleaning of the heater.  All

other servicing is to be done by qualified service personnel.

2. Because of the convection heating principle which depends

upon a circulation of air through the finned element, dust will
collect between the fins. The heater should be cleaned regu-
larly for maximum efficiency.  

3. To clean heating element fins, first remove both wiring com-

partment covers and the front cover. Using a vacuum cleaner
or compressed air, remove the dust and lint from the alu-
minum heating element fins while being careful not to dam-
age the fins. 

4. The painted heater cabinet may be cleaned using a slightly

damp cloth. Do not use abrasive cleaners or waxes as these
may damage the finish or leave a residue that will discolor.

5. Replace front cover (making sure it is latched in place at

each element support bracket and at each end) and two
wiring compartment covers (using the two screws provided),
restore power and check heater for proper operation.

Painting

If it becomes necessary to repaint heater, use only a quality
enamel paint suitable for metal surfaces following the instruc-
tions provided with the paint. DO NOT paint the heating element
or safety limit capillary tube. Repaint only the exterior of the 
cabinet. 

1. Serious injury or death could result from electric shock.

Make sure electrical power supply circuit coming to heater
is disconnected at main disconnect or service panel before
servicing this heater.  Allow heater to cool before cleaning
to prevent a possible burn.

2. Use care when cleaning element fins to avoiding damaging

fins.  Note also that fins are sharp and may cause cuts so
avoid contact.

3

Figure 4: Left Side Wiring Compartment Shown

Bottom mounting holes

Built in cable clamp

Mounting perforations

Safety limit DO

NOT BYPASS

Capillary tube

Summary of Contents for 2500 & C2500 Series

Page 1: ...fort heating in residential and commercial applications Baseboard heaters must be thermostatically controlled for efficient safe opera tion A thermostat is not provided with this heater However a single or double pole thermostat accessory is available for installa tion into this heater at your place of purchase or the heater may be connected to any suitable wall mounted thermostat that will meet t...

Page 2: ...rom the parts kit in wiring compartment in the knockout holes d Wire heater according to wiring diagrams in Figure 5 Attach the wireway cover using the screws TO REDUCE THE RISK OF FIRE AND ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 Serious injury or death could result from electric shock Make sure electrical power supply circuit coming to heater is disconnected at main disconnect...

Page 3: ...our This should remove oily residue from manufacturing Some smoking may occur 4 Select the setting for comfort on all thermostats 5 A safety limit control is provided to turn off the heater auto matically if it is blocked or otherwise overheats due to an abnormal condition see Figures 4 and 5 DO NOT bypass or remove this safety device from the electrical circuit see Warning 11 on page 2 During nor...

Page 4: ...hin the limitations of this warranty inoperative units should be returned to the nearest Marley authorized service cen ter or the Marley Engineered Products Service Center and we will repair or replace at our option at no charge to you with return freight paid by Marley It is agreed that such repair or replacement is the exclusive remedy available from Marley Engineered Products THE ABOVE WARRANTI...

Page 5: ...o complementaria para calefacción ambiental en aplicaciones residenciales y comerciales Los calefactores de zócalo para asegurar un funcionamiento eficiente y seguro deben estar controlados termostáticamente No se suministra termostato con este calefactor Sin embargo en el lugar donde compró el calefactor se ofrece un accesorio de termostato unipolar o bipolar para instalar en el mismo o también p...

Page 6: ...LIGRO DE INCENDIO CHOQUE ELÉCTRICO O DAÑO A LAS PERSONAS OBSERVE LO SIGUIENTE 1 Un choque eléctrico podría producir lesiones graves o la muerte Asegúrese de que el circuito de alimentación eléc trica del calefactor esté desconectado en el tablero de ser vicio o desconectador principal antes de instalar este cale factor 2 Los procedimientos de cableado y las conexiones deben estar de acuerdo con el...

Page 7: ... ninguno está funcionando lleve los termostatos a su posición máxi ma y espere de 3 a 5 minutos Compruebe que el calefactor todos los calefactores esté n funcionando Si alguno no estuviera funcio nando desconecte la alimentación eléctrica y revise el cableado 3 Deje funcionar el sistema en forma continua durante hora Esto debe eliminar los residuos aceitosos que hayan quedado de la fabri cación pu...

Page 8: ...izado más cercano comuníquese con Marley Engineered Products en Bennettsville SC Estados Unidos llamando al 1 800 642 4328 Toda mercadería regresada a la fábrica debe ser acompañada por una autorización de retorno y una etiqueta de identificación de servicio disponibles ambas en Marley Engineered Products Cuando solicite la autorización de retorno incluya todos los números de catálogo mostrados en...

Page 9: ...nnées de fonctionnement sans soucis comme source de chaleur principale ou auxiliaire pour du chauffage de confort dans des applications résidentielles et commerciales Les radiateurs plinthes doivent être thermosta tiquement contrôlés pour un fonctionnement efficace et sûr Il n est pas fourni de thermostat avec ce radiateur Cependant un ther mostat accessoire unipolaire ou bipolaire est disponible ...

Page 10: ...DE BLESSURES AUX PERSONNES OBSERVEZ LES CONSIGNES SUIVANTES 1 Une blessure sérieuse voire mortelle peut résulter d une commo tion électrique Assurez vous que le circuit du secteur d alimenta tion électrique arrivant au radiateur est bien débranché en amont à l interrupteur général ou au panneau de service avant d installer ce radiateur 2 Les procédures de câblage et les connexions doivent être en ...

Page 11: ... les radiateurs chauffent bien Si un radiateur ne chauffait pas débranchez le et vérifiez le câblage 3 Laissez le système complet fonctionner régulièrement pendant 1 2 heure Cela devrait éliminer tous les résidus huileux de la production Il peut se produire un peu de fumée 4 Choisissez un réglage de confort sur tous les thermostats 5 Un contrôle de limite de sécurité est fourni pour couper automat...

Page 12: ...fiques mais il est possible que vous ayez également d autres droits selon votre lieu de rési dence Pour connaître l adresse du centre de réparation agréé le plus près contactez la société Marley Engineered Products à Bennettsville Caroline du Sud au 1 800 642 4328 Les produits retournés à l usine doivent être accompagnées d un numéro d autorisation de retour et d une étiquette d identification de ...