Doc No: SM-351 Iss A 18.07.16

Marlec Eng Co Ltd

Power Up to Default Screen

Start Monitoring

Press the WG and PV buttons on the 1200 Hybrid Controller.
Amps and Watts for each charge source are displayed.  Any one of the following is also displayed:
CHG— Charging,
ON— Charge source is on but there is no voltage to start charging.
SBY–  Standby, charge source is on but there is insufficient voltage to start charging.
Note: Any button press on the remote with the backlight off will switch it on and start it's countdown

timer (default 30s), further button presses when the backlight is on perform functions as shown below.

Using the Remote Display

Press the DOWN and UP buttons to scroll through the available screens;

WG (Amps) - PV (Amps) - Total (Amps) - Default Screen

The screen can be left to display on any screen, the default screen is recommended.

When the charge source, WG or PV, has been shutdown, either at the controller or via the Remote,
SWITCHED OFF is displayed.

Battery 2 is shown as
not connected.

Bulk Phase or Float
Phase is displayed

WG = Wind Generator

PV = Photovoltaic

panel

Battery symbols
change to show

approximate level
of charge 0%, 25%,

50%, 75% & 100%

Flashing empty battery   Indicates low battery warning
Flashing full battery

Indicates regulating mode

WG or PV Switched OFF   Coincides with Red illuminated

button on controller

WG or PV or

Total is dis-

played by

scrolling through

UP and DOWN

The scale and bar
graph alter in

response to the
levels of energy to

display

Accumulated

Ampere hours and
duration of
monitoring elapsed

3

Summary of Contents for Rutland 1200

Page 1: ...Doc No SM 351 Iss A 18 07 16 Marlec Eng Co Ltd Rutland Remote Display Model 1200 Installation and Operation ...

Page 2: ...ailable at www marlec co uk Introduction The Rutland Remote 1200 Model is designed for use with the Rutland 1200 Wind Turbine It enables convenient viewing of the wind generator and PV solar panel charge currents power battery Voltages charging status and accumulated ampere hours of charge to the batteries It connects to the Rutland 1200 Hybrid Controller via a serial cable and mounting is optiona...

Page 3: ...for the unit is provided from the WG1200 controller via the serial data cable supplied Locate the RJ11 sockets on the controller and display unit to connect the 2 devices The screen will power up Press any button to illuminate the backlight Note In late 2016 a wireless Bluetooth kit will be available which will plug in at each end in place of the cable The Remote Display will require a local 12 24...

Page 4: ...uttons to scroll through the available screens WG Amps PV Amps Total Amps Default Screen The screen can be left to display on any screen the default screen is recommended When the charge source WG or PV has been shutdown either at the controller or via the Remote SWITCHED OFF is displayed Battery 2 is shown as not connected Bulk Phase or Float Phase is displayed WG Wind Generator PV Photovoltaic p...

Page 5: ...A cursor indicates the option available to select Option 1 Charge Sources On Off Toggle the UP and DOWN buttons to change between ON and OFF Press ENTER to Exit Note that when switching WG to OFF the controller enters a soft stall routine this slowly applies the stall to decelerate the turbine During this routine the following is displayed and when complete the display returns to the programming m...

Page 6: ...ime for both the WG and PV simultaneously Option 3 Backlight On Time This function adjusts the length of time the backlight will remain on following a button press The default On time duration is 30 seconds Adjust the seconds using the UP and DOWN buttons to the desired duration one press adjusts one second Press ENTER to save this time to non volatile memory and return to the programming menu 5 ...

Page 7: ...ay is automatically resumed except in the case of PV over current See below 2 If Current screen is selected the WG and PV screens will display as follows Caution PV Over Current PV Over Current is a permanent error indicating that a PV array current exceeding the maximum possible 20A has been connected The error indication is only removed following a controller reset A PV array within permissible ...

Page 8: ... to the manufacturer Marlec Engineering Company Limited Rutland House Trevithick Road Corby Northamptonshire NN17 5XY England or to an authorised Marlec agent This Warranty is void in the event of improper installation owner neglect misuse damage caused by external factors This warranty does not extend to ancillary equipment not supplied by the manufacturer No responsibility is assumed for inciden...

Reviews: