![marklin 76495 User Manual Download Page 12](http://html1.mh-extra.com/html/marklin-0/76495/76495_user-manual_1729180012.webp)
12
CV for fx (MM) and DCC
With fx (MM) the address can be set only with the DIP switches.
The values in parentheses are factory default settings.
CV Meaning
Values
1 Address 1 - 255
1-255 (1) only DCC
9 Addresses 256 - 2040
0-7 (0) only DCC
33 Numer of output
addresses
—
read only DCC
40
PoM*
Meaning Lighting
0 - 15 (15) 0 light off
Dimming 0-15,
whereby 15 = 100%
brightness
45
PoM*
Signal Type Home signal:
76495
76497
76496
2
3
4
Block signal
Entry signal
Exit signal
46
PoM*
Signal Type Distant Signal
2
3
4
belongs to
Block signal
Entry signal
Exit signal
48
PoM*
Home Signal
Switching duration
LED on/off
0 - 3
0 = 0 seconds
1 = 0.175 seconds
2 = 0.35 seconds
3 = 0.5 seconds
CV Meaning
Values
50
PoM*
Cross fading behavior
Home signal
0 - 3
0 = simultaneously
1 = one after the other
2 = one after the other
0.1 sec. pause
3 = one after the other
0.5 sec. pause
52
PoM*
Distant Signal
Switching duration
LED on/off
0 - 3
0 = 0 seconds
1 = 0.175 seconds
2 = 0.35 seconds
3 = 0.5 seconds
54
PoM*
Cross fading behavior
Distant Signal
0 - 3
0 = simultaneously
1 = one after the other
2 = one after the other
0.1 sec. pause
3 = one after the other
0.5 sec. pause
55 Distant Signal Address,
short (like CV1)
only DCC
enter the value of the
home signal belonging
to it (only DCC)
56 Distant Signal Address,
long (like CV9)
only DCC
enter the value of the
home signal belonging
to it (only DCC)
*PoM programming can be done on the main track as long as it
is supported by the control device.
Setting and Calculating Addresses Greater than 255 (DCC):
Example: Address 1044 -> 1044 : 256 = 4.078125. The value before
the decimal point (4) is entered in CV 9. The value after the
decimal point (0.078125) is multiplied by 256 0.078125 x 256 = 20.
The calculated value of 20 must be entered in CV 1.