Markilux 6000 Fitting Instructions Manual Download Page 10

 
 

 

10 

8.   Awning with lighting (two lamps per unit) 
8.1 Overview 

 

 

Lighting profile 

Cap 

Holder 

Acrylic glass lighting tube colorless satin 

finish 

Fluorescent lamp 

 

Osram FQ 39 W / 827 

Mask

 

Starter casing

 

 

 Electrical work: Electrical installations must be carried by a qualified electrician according to VDE 0100.  

 

8.2 Lighting with dimmer

 

 

8.2.1

  The  cable  for  the  lighting  connection  is 

marked with this sticker. 

The  wiring  diagram  must  definitely  be  observed,  a 
faulty connection can lead to the destruction of the 
device! 
 

Wire color

 

Terminal

 

(1)  gray 

Control voltage dimmer 10V (+) 

(2)  black 

Control voltage dimmer 10V (-) 

(3)  brown 

230V~ voltage supply phase 

(4)  blue 

230V~ voltage supply neutral 
conductor 

(5)  
green/yellow 

230V~ voltage supply protective 
conductor 

8.2.2 

For the connection of the supply and control 

cable,  5  approved  screw  terminals  or  non-screwed 
terminals  with  a  rated  voltage  of  at  least  230  V~ 
are required. 

 

Attention  Danger  to  Life: 

Electrical  operation 

without  protective  conductor  connection  is  not 
permitted! It is to be observed, that during operation 
the  protective  conductor  (5)  green/yellow  is  neither 
interrupted in/on the product nor by the mains cable. 
 
All  electrical connections  and  connection  leads must 
definitely  be  checked  after  being  connected  and 
before the first trial operation!

 

 

8.2.3  

Technical data of a lamp: 

Power supply:   

            

230 VAC 

 

 

 

 

 

50 Hz (10/16A) 

Max. wattage:  

 

 

39W  

Lamp:   

 

            OSRAM FQ39W/827 

System of protection:  

 

IP54 

Supply cable cross-section:   min. 1.0 mm² 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for 6000

Page 1: ...al cover X Value from Table 2 K Headroom G X G Fitting height W Pitch angle Table of fitting heights at a pitch angle of 5 to 35 Projection in cm 150 200 250 300 350 400 W 5 X 26 28 30 32 34 36 Y 148 198 248 298 348 398 W 10 X 36 43 50 57 74 81 Y 146 196 246 296 346 396 W 15 X 47 59 70 81 92 103 Y 144 193 242 291 340 389 W 20 X 58 74 90 106 122 138 Y 141 189 237 285 333 381 W 25 X 70 89 108 127 14...

Page 2: ... cassette A arm position 1 2 2 Considering fastening materials and types of mounting according to the background type of mounting A or B The mounting background must be specified when ordering the awning Fastening materials are not supplied since different backgrounds e g concrete chalky sandstone gas concrete etc require different fastening materials Depending on the background different fastenin...

Page 3: ...termine the position of the fixtures according to the stickers already provided red points on the back of the cassette see also 1 2 1 Face Fixture 1 3 2 Attention The distance of the bracket to a possibly existent wall must be at least 65mm 1 3 3 Concrete B 25 is presumed as fastening background Fastening materials are not supplied different fastening systems are offered by fastenings manufacturer...

Page 4: ...tes according to the background Align the fastening fixtures horizontally 1 4 Eaves Fixture Sizes in mm Sizes in mm 1 4 1 Determine the fitting height Determine the position of the fixtures according to the stickers already provided red points on the back of the cassette see also 1 2 1 Face Fixture ...

Page 5: ...t the screw holes Screw fixture with suitable fastening materials Align the fastening fixtures horizontally 2 Hanging the awning e g face fixture 2 1 Place the awning on the wall fixtures tilted slightly upwards 2 2 Let the casing rest on the rear slot and the clamping plate 2 3 Tightly screw the two outer socket head cap screws of the clamping plate SW8 ...

Page 6: ...ed out at works If it needs to be altered or corrected one must proceed according to the motor instructions with radio portable transmitter without radio setting cable Direction of rotation when retracting ATTENTION A coiling of the cover onto the roller from below can lead to the awning being damaged when retracted When altering the end positions definitely observe the direction of rotation 3 2 I...

Page 7: ...ning extended first loosen the side clamping screws SW 19 of the fixtures 4 2 Raise arm and relieve the load By turning the front face socket head cap screw SW 8 adjust the pitch angle 4 3 Firmly retighten the clamping screws SW 19 of the fixture 5 Arm position with awning retracted 5 1 If with awning retracted one arm is positioned too high or too low and because of this the front profile does no...

Page 8: ... SW 4 1 and SW 10 2 on the inner bracket 6 Fixture covers 6 1 Face fixture cover 6 1 1 From an awning pitch angle of approx 15 it is necessary to cut out the plastic covers of the wall fixtures at the thin walled bridges with a safety knife according to the pitch angle setting Screw on wall cover 6 1 2 Screw on wall cover with socket head cap screw SW 5 ...

Page 9: ...ring size dependent Despite the factory setting with local pitch angle adjustment a correction may be necessary The Rolltex bearing has two setting options for an optimal travel of the cover 1 Greatest tension of the transport band with a small front awning profile By evenly turning the two SW 3 set screws 1 clockwise the transport band is tensioned relieved by turning evenly anti clockwise 2 With...

Page 10: ...ge supply phase 4 blue 230V voltage supply neutral conductor 5 green yellow 230V voltage supply protective conductor 8 2 2 For the connection of the supply and control cable 5 approved screw terminals or non screwed terminals with a rated voltage of at least 230 V are required Attention Danger to Life Electrical operation without protective conductor connection is not permitted It is to be observe...

Page 11: ...product nor by the mains cable All electrical connections and connection leads must definitely be checked after being connected and before the first trial operation 8 3 3 Technical data of a lamp Power supply 230 VAC 50 Hz 10 16A Max wattage 39 W Lamp OSRAM FQ39W 827 System of protection IP 54 Supply cable cross section min 1 0 mm 9 Awning with Shadeplus and Motor Drive with radio 433 MHz U 230 V ...

Reviews: