INSTALLATION AND OPERATION MANUAL AND PARTS,
ELECTRIC CONVECTION STEAMERS, MODELS: ST-7-TE, ST-10-TE
PART NUMBER 10175R2
8
2006-01-19
WATER QUALITY
(Continued)
2. The water level probes become coated with scale. Scale will bridge across the probe
insulator from the metal extension which senses the water level in the boiler shell. Once
this scale becomes wet, the water level control is unable to maintain the proper water level
in the boiler. This situation may cause an electric heating element to fail if the element is
not adequately covered by water.
Strainers and filters will not remove minerals from the water.
Refer to REMOVAL OF LIME SCALE DEPOSITS, page 19.
VENT HOOD
Some local codes may require the steamer to be located under an exhaust hood. Information
on the construction and installation of ventilating hoods may be obtained from NFPA Standard
No. 96,
Vapor Removal from Cooking Equipment
, (latest edition).