17
GENERAL TOUBLE SHOOTING GUIDE
____________________________________________________________________________
TROUBLE
POSSIBLE CAUSE
REMEDY
Water does not enter boiler.
Water main shut-off.
Power not reaching unit.
Probes dirty.
Water level control board
defective.
Solenoid valve defective.
1.
2.
3.
4.
5.
Turn on.
Check main fuse or circuit.
3. Remove and clean.
See (
page 8
) for test proce
-
dure.
If 120V is verified at sole
-
noid coil, but fails to open,
replace solenoid.
1.
2.
3.
4.
5.
Water enters boiler very slowly.
Dirty strainer screen in sole-
noid valve.
1.
Clean or replace strainer
screen.Part No. 08-4871
1.
Water level in gauge glass fluctu
-
ates up and down.
Top shut off on water gauge
is closed.
1.
Open.
1.
Boiler fails to build up
pressure when water level is
proper and fuel switch is turned
on.
Check to see that circuit
breaker in main is turned on.
Check to see that contactors
are pulling in.
Current flow is broken at
water level control (
ascertain
with continuity check
).
Current flow is broken at
pressure control or high limit
control switches due to mal
-
adjustment or defect (
ascer-
tain with continuity check
).
Heating elements are defec
-
tive.
1.
2.
3.
4.
5.
Check for voltage at terminal
block.
Check continuity of coil, if
open replace.
Check for voltage at L1 and
L2, replace if defective.
Readjust - to proper set
-
ting - refer to instructions
for readjustment, replace if
defective.
Replace if continuity check
through the circuit of each
element shows defective.
1.
2.
3.
4.
5.
Boiler fails to reach full operating
pressure of 5 lbs. or 15 lbs.
Pressure gauge reads inac
-
curately.
Pressure control and high
limit control switches are out
of adjustment.
Safety valve not seating
properly.
Contactor coils (
one or both
)
not energizing and closing
circuit to the heating ele
-
ments.
1.
2.
3.
4.
Replace.
Follow instructions for read
-
justing or replace if defec
-
tive.
Clean or replace.
Check - replace either con
-
tactor
coils or complete contactor
- if found defective. Measure
amperage at terminal block
check to be sure there is an
even draw on all three phas
-
es - see wiring diagrams for
correct AMP draw. If uneven
or zero amperage draw is
found on one of the three
phases, check for blown
fuse. If fuse is OK, shut off
power, remove wires from
heating elements and run
continuity check - replace if
defective.
1.
2.
3.
4.
5.
Product in cooker does not
cook properly on first cycle, but
cooks alright after first cycle is
exhausted.
Airvent is closing.
1.
Replace.
1.