background image

FT-12CG

GAS FIRED STEAM JACKETED TILTING KETTLE

INSTALLATION  - OPERATION - MAINTENANCE

Telephone: (802) 658-6600 Fax: (802) 864-0183

www.marketforge.com

 

PN 14-0366 Rev A (9/14)

© 2014 - Market Forge

Summary of Contents for FT-12CG

Page 1: ...FT 12CG GAS FIRED STEAM JACKETED TILTING KETTLE INSTALLATION OPERATION MAINTENANCE Telephone 802 658 6600 Fax 802 864 0183 www marketforge com PN 14 0366 Rev A 9 14 2014 Market Forge ...

Page 2: ...Your Service Agency s Address Model Serial number Oven installed by Installation checked by ...

Page 3: ...SMELLS GAS MUST BE POSTED IN A PROMINENT LO CATION This information may be obtained by contacting your local gas supplier FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors or liq uids in the vicinity of this or any other appliance The information contained in this manual is important for the prop er installation use and mainte nance of this oven Adherence to these procedures a...

Page 4: ...e sequence of operation is as follows 1 Operator turns the power switch to the on position and sets the temperature control dial to the desired setting 2 The red light comes on indicating the kettle is heating The green IGNITION light comes on indicating that the ignition and burner are active 3 Once the kettle reaches the set temperature the red TEMPERATURE light and the green IGNITION light exti...

Page 5: ... 152 355mm Propane 12 14 W C 305 355mm Contact manufacturer for installation over 2 000 ft elevation CW Cold Water 3 8 O D tubing to faucet optional HW Hot Water 3 8 O D tubing to faucet optional DIMENSIONS ARE IN INCHES MM G 25 39 645 EC 4 75 121 3 76 23 75 603 FLANGE FOOT DETAIL 4 EQUALLY SPACED Ø7 16 11 HOLES ON 3 76 B C Ø20 508 Ø16 75 425 I D 15 88 403 30 762 6 152 55 75 1416 49 75 1264 32 88 ...

Page 6: ...appliance to the electrical supply until after the gas connection has been made CAUTION The pipe thread compound used when install ing pipes must be a type that is resistant to the action of liquefied petroleum or propane gases 1 The Serial and Rating Plate on the unit indicates the type of gas your unit is equipped to burn DO NOT connect to any other gas type 2 A 3 4 NPT line is provided at rear ...

Page 7: ...chor ing holes provided in the flanged adjustable feet 7 Remove the appliance from installation position and drill holes in locations marked on the floor Insert proper anchoring devices Not supplied 8 Place appliance back in the installation position and Re level left to right and front to back 9 Bolt and anchor appliance securely to the floor 10 Seal bolts and flanged feet with silastic or equiva...

Page 8: ...he tilt knob located on the console at the top left This feature locks the ket tle in the upright position and also allows the operator to lock the kettle at 105 degrees for ease of cleaning Follow these steps to tilt kettle 1 Pull out the tilt knob at the top left of console 2 Using kettle tilt handle pull kettle forward to desired angle of pour or until kettle locks at 105 degrees The tilt knob ...

Page 9: ...eated and remain at room temperature during the entire cleaning process 2 If the stain resists removal additional exposure time with vinegar may be required to a maximum of one hour 3 Thoroughly wash all of the vinegar away with fresh clear water Dry the surface completely and allow one hour before using the appliance to cook Following daily and period maintenance procedures will prolong the life ...