4
INSTALLATION
Service Connections
Figure 2
ALTAIR II-8, ALTAIR II-10 AND ALTAIR II-12
ELECTRICAL CHARACTERISTICS
ELECTRICAL (4 PAN STEAMER) 60 Hz
Voltage
pH
kW
Amps
208
1
8
38.5
240
1
8
33.3
208
3
8
22.2
240
3
8
19.3
480
3
8
9.6
ELECTRICAL (6 PAN STEAMER) 60 Hz
Voltage
pH
kW
Amps
208
1
9.8
47.1
240
1
9.8
40.8
208
3
9.8
27.2
240
3
9.8
23.6
480
3
9.8
11.8
DIMESIONS ARE IN INCHES [MM]
24.00 [610]
19.00 [483]
3.88
[98]
4.75
[121]
2.00
[51]
20.00 [508]
FRONT VIEW
6.00 [152]
A/B
15.38 [391]
22.38 [568]
C
A/B
26.25 [667]
32.25 [845]
C
A
52.50 [1334]
59.50 [151
1]
66.50 [1689]
B
C
Steam Vents
2.00
[51]
3.25 [83]
8.50 [216]
REAR VIEW
Water in each unit
requires water line
30.75 [781]
2.00
[51]
28.75 [730]
17.75
[451]
Pull out
service
drawer
Door is in
open position
2.00 [51]
22.00 [559]
4.75 [121]
SIDE VIEW
A
Altair II-8
Altair II-10
Altair II-12
B
C
WATER SUPPLY & DRAIN
Good quality water feed is the responsibility of the owner. Water quality must be within the
following general guidelines.
TDS: 40-125 ppm
Hardness: 35-100 ppm
pH: 7.0 - 8.5
Silica: <13 ppm
Chlorides: <25 ppm
Chlorine: <0.2 ppm
Chloramine: <0.2 ppm
The best defense against poor water quality is a water treatment system designed to meet
your water quality conditions.
Pressure:
25(min)-50(max) PSI
Connections: Trough drain: 1/2 MNTP Drain out: 1” FNPT Water: 3/4” male garden hose
Appliance to be installed with backflow protection according to federal, state or local codes.
The drain piping must consist of temperature resistant material, greater than 160°F, and be
of adequate diameter not to cause flow restriction. Improper materials may deform and cause
restrictions, thus affecting performance.
NOTES
Each single compartment has a separate rear exiting drain plumbed directly into the
stacked steamers main drain/vent line.
4” clearance left mandatory, right and rear is recommended.
Location near a floor drain is recommended.
Refer to electrical characteristics chart for voltage requirements of each steamer.
Each compartment requires separate electrical & water connection.