10

MAINTENANCE

Cleaning Guidelines

Daily Cleaning

Once the power is off and the reservoir has been drained, 

a simple cleaning process should be followed:

   WARNING

The cooking chamber is designed to retain 

heat. It may still be hot to the touch when 

cleaning. Wear protective gloves, or wait for 

the surface to cool before cleaning. Do not 

add cold water to a hot, empty cooking cham-

ber until it has cooled down, or damage may 

result.

1. 

Lift the pan racks up and off mounting screws, and 

remove from the steamer for cleaning.

2.  Lift reservoir cover out of cooking chamber compart-

ment, clean cover.

3. 

Remove the drain/overflow standpipe, clean, making 

sure overflow holes are clear and open.

4.  Using a soft sponge, clean the non-stick coating on 

the interior of the cooking chamber.

5.  Clean the door gasket with gentle soap and water 

and allow to air dry.

NOTICE:

 Only use mild soap, white vinegar, and 

water to clean your steamer. Do not use abrasive 

utensils, caustic cleaners, or products containing 

chlorine, lye, or phosphorus (such as Lime-A-Way). 

After cleaning, rinse thoroughly by wiping with a wet 

cloth dampened with fresh water. Never spray water 

on your steamer.

FAILURE TO FOLLOW PROPER INSTRUCTIONS 

MAY CAUSE AN UNSAFE CONDITION AND/OR 

DAMAGE YOUR STEAMER, AND WILL VOID 

YOUR WARRANTY.

6.  Rinse the cooking chamber and door area with clean 

water. Rinse the cavity.

7.  Wipe with clean towel or soft sponge.

8.  To remove the white mineral deposits at and below 

the water line, spray white vinegar directly on the 

mineral build-up using a spray bottle. For heavy min-

eral deposits, replace drain/overflow standpipe, pour 

two cups of white vinegar in the water reservoir and 

turn on steamer to add enough water to cover the 

white minerals, let soak for half an hour or overnight. 

Loosen mineral deposits with a nylon bristled brush. 

Drain, wipe and rinse. Use water and white vinegar to 

clean reservoir.

9.  Make sure two stainless probes on lower backside of 

cooking chamber interior are clean.

10. Wipe out the condensate trough located under the 

door. Remove food particles. Make sure the drain is 

kept clear.

NOTE:  It  is  always  advisable  to  leave  the  steamer 

door open when the unit is shut down for the 

evening. This will extend the life of your gas-

ket.

NOTE: It is normal for the white lime to collect at the 

water line and in the reservoir area. Liming 

is easily removed with daily cleaning – white 

vinegar is very effective and will not damage 

the cooking chamber. Use only white vinegar 

and water to clean reservoir on a daily basis.

11. 

Replace the drain/overflow standpipe and the reser

-

voir cover. The reservoir cover and the drain/overflow 

standpipe must be replaced or the steamer will not 

function properly.

Your steamer is now ready for another day’s work! 

Weekly Cleaning

In addition to the daily cleaning it is necessary to clean 

the air intakes on a weekly basis. Air intakes provide nec-

essary cooling air to the internal components. They are 

generally located on the rear and sides of the equipment.

Summary of Contents for ALTAIR II Series

Page 1: ...CTION STEAMER INSTALLATION OPERATION MAINTENANCE Telephone 802 658 6600 Fax 802 864 0183 www marketforge com PN 14 0267 Rev G 3 18 2018 Market Forge MODELS Altair II 4 Altair II 6 Altair II 8 Altair II 10 Altair II 12 ...

Page 2: ...Your Service Agency s Address Model Serial number Steamer installed by Installation checked by ...

Page 3: ...TANT WARNING Improper installa tion adjustment alternation service or maintenance can cause property damage in jury or death Read the instal lation operation and mainte nance instructions thoroughly before installing or servicing this equipment FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors or liq uids in the vicinity of this or any other appliance The information contained...

Page 4: ... will void the war ranty 4 High water sensor Two water level sensors are located on the lower backside of the steamer The lower sensor activates the waterfill mechanism The upper sensor will shut off water flow if an overflow situation occurs It is important that both sensors are kept clean so that the stainless part is shiny WARNING Failure to keep both water level sensors clean may result in hot...

Page 5: ...the following general guidelines TDS 40 125 ppm Hardness 35 100 ppm pH 7 0 8 5 Silica 13 ppm Chlorides 25 ppm Chlorine 0 2 ppm Chloramine 0 2 ppm The best defense against poor water quality is a water treatment system designed to meet your water quality conditions Pressure 25 min 50 max PSI Connections Trough drain 1 2 MNTP Drain out 1 FNPT Water 3 4 male garden hose The drain piping must consist ...

Page 6: ...r quality must be within the following general guidelines TDS 40 125 ppm Hardness 35 100 ppm pH 7 0 8 5 Silica 13 ppm Chlorides 25 ppm Chlorine 0 2 ppm Chloramine 0 2 ppm The best defense against poor water quality is a water treatment system designed to meet your water quality conditions Pressure 25 min 50 max PSI Connections Trough drain 1 2 MNTP Drain out 1 FNPT Water 3 4 male garden hose Appli...

Page 7: ...N CONNECTION Water hookup Steamer requires water line Termina tion is male garden hose connection Make sure wa terline is flushed to remove grit and soldering particles prior to connecting steamer Dirty water lines may affect solenoid operation Double stacked compartment steamers require sepa rate water connections which may be manifolded Inad equate water supply may cause one steamer not to fill ...

Page 8: ...nterior of the cooking chamber to remove shipping debris prior to use Rinse with clean water CAUTION Do not use any abrasive cleaners utensils or scrubbers on the non stick coating Use vine gar and water to clean reservoir Nylon bristle brushes or soft sponges are recommended 4 Make sure drain overflow standpipe is fitted firmly into cooking compartment drain opening 5 Install reservoir cover with...

Page 9: ...door is open nothing will happen Close the door and the steamer will turn on and be gin warming up Door operation The door must be closed at all times while cooking If the door is opened during cooking the heaters will shut down and the Amber HEAT light will go off until the door is closed You may open the door at any time to check the progress of cooking stir product and add or remove cooking pan...

Page 10: ...y foods can be blanched in atmospheric steam be fore being finished in ovens fryers or on grills and grid dles This reduces total cooking time helps ensure com plete cooking and a moist product Potatoes poultry and seafood are excellent examples Blanching before frying reduces grease absorption by food products Tips on pan use For faster cook times 2 deep perforated pans are recommended It is not ...

Page 11: ...outlets clear and unob structed may result in hot water flowing out the door of the steamer A blocked overflow and drain could al low water to flow to the countertop or floor which can cause slippery conditions Modifying the steamer to operate without the overflow standpipe could cause dangerous situations and will void the warranty Failure to keep both water level sensors clean may result in hot ...

Page 12: ...e 8 To remove the white mineral deposits at and below the water line spray white vinegar directly on the mineral build up using a spray bottle For heavy min eral deposits replace drain overflow standpipe pour two cups of white vinegar in the water reservoir and turn on steamer to add enough water to cover the white minerals let soak for half an hour or overnight Loosen mineral deposits with a nylo...

Page 13: ...sure the steamer is off and cool 2 Drain water from the cooking cavity and wipe away any food debris 3 Make sure the drain is plugged 4 Pour one pound of Optipure DSP per steamer into the bottom of the cooking cavity NOTE One pound is equal to 16 scoops measuring scoop included or one half of a 2lb jar of descaling powder 5 Set the control to Steam 2 position This will auto matically fill the unit...

Reviews: