background image

 

 

SUPERLED 818 IP             - 1 -          

User Manual/Manual de Uso

                 

1.

Summary

Summary

Product introduction

Packing List

 

SUPERLED 818 IP

               1 PC

 

DMX Signal Cable                         1 Set

 

Waterproof  input power cable      1 PC

User Manual

Thanks you for purchasing

 SUPERLED 818 IP

. Please, read these instructions carefully before begin 

and operate the fixture according to these instructions to avoid possible damages and accidents 

causing by misusage.

SUPERLED 818 IP

It adopts high power 4-in-1 LED, which refers to single LED is made of R,G,B, W 4-in-1 LED, and long

life span, low consumption, good color mixing effect and high brightness are the most prominent

features. Each kind of LED can be independently dimmed. The built-in programs include dimming

stroble, gradual change and fading. It uses power switch, performs low weight and consumption,

stable capability and long life. Standard DMX 512 signal is requested.

 uses casting aluminum housing, designed in a fashion form.

2. Safety Instructions

Safety Notes

 

 

 

- Enquire the authorized technical people to repair the unit.

- Always make sure disconnect from the power source before setting up, serving and moving.

- Avoid direct eye exposure to the fixture when it is on.

 

EN

Make sure the power supply voltage are consistent with this device. Ensure the use of voltage is in 

the range of the technical parameters requested.

Before the installation, please, check if the device is in good conditions and appears no damage.

This device is designed for indoor/outdoor use thanks to IP 65 rating.

The fixture maybe mounted in any position provided there is adequate room for ventilation. Make sure

there are no inflammable and explosive items in 0.5 meter around.

Yellow/green cable cabling earthling safety, do not remove it

 

Summary of Contents for SUPERLED 818 IP

Page 1: ...Rev 161202 SUPERLED 818 IP User Manual Manual de Uso...

Page 2: ......

Page 3: ...switch performs low weight and consumption stable capability and long life Standard DMX 512 signal is requested uses casting aluminum housing designed in a fashion form 2 Safety Instructions Safety No...

Page 4: ...512 stand alone sound activated Channel 1 0 CH 7 CH 5CH 4 CH 3 CH Function Effect dimmer strobe gradual change Touch buttons automatic lock key Built i n temperature control measurement function when...

Page 5: ...pulse slow to fast 181 220 Closing pulse slow to fast 221 255 Electronic Squarewave slow to fast CH7 CH 7 prior to CH9 0 10 No effect 11 15 CT01 16 20 CT02 21 25 CT03 26 30 CT04 31 35 CT05 36 40 CT06...

Page 6: ...Green Red 0 Green full Blue 0 step 92 130 Red up Green full Blue 0 proportional 131 Yellow Red full Green full Blue 0 step 132 170 Red full Green down Blue 0 proportional 171 Red Red full Green 0 Blue...

Page 7: ...ration SUPERLED 818 IP 5 User Manual Manual de Uso EN MenuTree Tab Level 1 Level 2 Level 3 Level 4 ADDR Address 001 512 STAT Static control R 0 255 G 0 255 B 0 255 W 0 255 SHUT 0 255 PRSC Preset color...

Page 8: ...W 0 255 CT10 AUTO Auto AT01 RUN AT02 RUN AT03 RUN AT04 RUN AT05 RUN ATSP 0 255 S CHS1 RUN CHS2 RUN CHS3 RUN PROG Program CHS1 Chase 1 SC01 Scene 1 R 0 255 G 0 255 B 0 255 W 0 255 SHUT 0 255 AUTO NONE...

Page 9: ...etting 2 Press the UP DOWN button to select 1 512 numerical value 3 Press the ENTER button to escape and save 6 2 STATIC SETTING 1 Press the ENTER button in STAT menu then enter to the static setting...

Page 10: ...DIM menu there will be added a little delay dimming effect for smooth Dimming curve Linear curve square law curve Inverse Square law curve S curve 6 6 DISPLAY SETTING 1 Press the ENTER button in DISY...

Page 11: ...ect CHASE01 CHASE03 3 Press the ENTER button for confirmation and enter to the next menu 4 Press the UP DOWN button to select SCENE01 SCENE20 5 Press the ENTER button for confirmation and enter to the...

Page 12: ...ENTER button in PR L menu then enter to the PROG self programming parameter reset 2 Press the UP DOWN button to select YES 3 Press the ENTER button to escape and save 6 14 LIGHTING PARAMETER DOWNLOAD...

Page 13: ...hacerlo funcionar con el fin de evitar posibles da os y accidentes causados por su mala utilizaci n 2 Instrucciones de seguridad Notas de seguridad Consulte s lo con personal autorizado para reparar l...

Page 14: ...R G B W 18 pzas Modo de control DMX 512 stand alone master slave Canales 3 4 5 7 y 10 canales Efectos dimmer strobo cambio gradual Botones touch bloqueo autom tico Funci n de control de temperatura S...

Page 15: ...nda quadr tica electr nica de lento a r pido 101 140 Strobo random de lento a r pido 141 180 Pulso abierto lento a r pido 181 220 Pulso cerrado lento a r pido 221 255 CH7 CH 7 prioriza a CH9 0 10 Sin...

Page 16: ...nal 91 Verde Rojo 0 verde full Blue 0 paso 92 130 Rojo sube verde full Azul 0 proporcional 131 amarillo Rojo full Verde full azul 0 paso 132 170 Rojo full verde baja azul 0 proporcional 171 Rojo Rojo...

Page 17: ...del par metro SUPERLED 818 IP 15 User Manual Manual de Uso ES Tab Level 1 Level 2 Level 3 Level 4 ADDR Address 001 512 STAT Static control R 0 255 G 0 255 B 0 255 W 0 255 SHUT 0 255 PRSC Preset color...

Page 18: ...T Custom color set CT01 R 0 255 G 0 255 B 0 255 W 0 255 CT10 AUTO Auto AT01 RUN AT02 RUN AT03 RUN AT04 RUN AT05 RUN ATSP 0 255 S CHS1 RUN CHS2 RUN CHS3 RUN PROG Program CHS1 Chase 1 SC01 Scene 1 R 0 2...

Page 19: ...12 3 Presione la tecla ENTER para salir y guardar 1 Presione la tecla ENTER en el men STAT para configurar el color est tico 2 Presione las teclas UP DOWN para seleccionar RED GREEN BLUE 3 Presione la...

Page 20: ...Presione la tecla ENTER en el men LOCK para entrar en la configuraci n de pantalla 2 Presione las tecla UP DOWN para seleccionar YES NO 3 Presione la tecla ENTER para salir y guardar 1 Presione la tec...

Page 21: ...men PROG para entrar en la edici n de programas autom ticos 2 Presione las tecla UP DOWN para seleccionar CHASE01 CHASE03 3 Presione la tecla ENTER para salir y guardar 4 Presione las tecla UP DOWN pa...

Page 22: ...eccionar YES 3 Presione la tecla ENTER para salir y guardar 1 Presione la tecla ENTER en el men SEND para entrar en el env o de par metros a otros dispositivos 2 Presione las tecla UP DOWN para selecc...

Page 23: ......

Page 24: ...EQUIPSON S A Avda El Saler 14 Pol Ind L Alter 46460 Silla Valencia Spain Tel 34 96 121 63 01 Fax 34 96 120 02 42 equipson equipson es www markpro es...

Reviews: