connections with the mains with particular caution! Never touch them with wet hands .as this could lead 

to mortal electrical shock. Never modify, bend, strain mechanically, put pressure on, pull or heat up the 

power cord. Never operate next to sources of heat or cold. Disregard can lead to power cord damages, 

fire or mortal electrical shock. The cable insert or the female part in the device must never be strained. 

There must always be sufficient cable to the device. Otherwise, the cable may be damaged which may 

lead to mortal electrical shock. Make sure that the power-cord is never crimped or damaged by sharp 

edges. Check the device and the power-cord from time to time.If extension cords are used, make sure 

that the core diameter is sufficient for the required power consumption of the device. All warnings 

concerning the power cords are also valid for possible extension cords.   

 

OPERATING DETERMINATIONS 

 

This device is designed for permanent operation. Consistent operation breaks will ensure that the 

device will serve you for a long time without defects. Do not shake the device. Avoid brute force when 

installing or operation the device. Never lift the fixture by holding it at the projector-head. As the 

mechanics may be damaged. When choosing the installation-spot, please make sure that the device is 

not exposed to extreme heat, moisture or dust. There should not be any cable lying around. Please 

make sure that the fixture can not be touched or bumped. Your endanger your own and the safety of 

others.   

 

The housing must never touch surrounding surfaces or objects. Make sure that the area below the 

installation place is blocked when rigging, dragging or servicing the fixture. For overhead use (mounting 

height>100cm), always fix the fixture with an appropriate safety-rope. Fix the safety-rope at the correct 

fixation points only. The safety-rope must never be fixed at the transport handles. Only operate the 

fixture after having check that the housing is firmly closed and all screw are tightly fastened.   

 

The maximum ambient temperature Ta=45

0

C must never be exceeded. Operate the device only after 

having become familiarized with its functions. Do not permit operation by persons not qualified for 

operating the device. Most damages are the result of unprofessional operation. Please use the original 

packaging if the device is to be transported. Please consider that unauthorized modifications on the 

device are forbidden due to safety reasons! Never remove the serial barcode from the device as this 

would make the guarantee void. If this device will be operated in any way different to the one described 

in this manual, the product may suffer damages and the guarantee becomes void. Furthermore, any 

other operation may lead to dangers like short-circuit, burns, electric shock, crash etc.   

 

DESCRIPTION OF THE DEVICE 

 

Features 

> 11 channel DMX-512 . 

> Pan :630

°

/tilt:270

°

V

36 pcs 8W RGBW QUAD LED

ariable electronic strobe. 

 

> Variable electronic dimmer(0-100%). 

> LED display menu with invert. 

> Reset to factory settings option.

> Pan/Tilt invert option

 

 

Zoom angle from 18º to 55º

Fan cooled

 

 

 

SIDIUS LED 368 Z              User Manual/Manual de uso      Page 2

EN

Summary of Contents for SIDIUS LED 368 Z

Page 1: ...Rev 13 07 01 SIDIUS LED 368 Z User Manual Instrucciones de Usuario...

Page 2: ...ely The arising condensation water might damage your device Leave the device switched off until it had reached room temperature Please make sure that there are no obvious transport damages should you...

Page 3: ...endanger your own and the safety of others The housing must never touch surrounding surfaces or objects Make sure that the area below the installation place is blocked when rigging dragging or servic...

Page 4: ...ling the device make sure there is no highly inflammable material decoration articles etc within a distance of min 0 5m DMX 512 connection connection between fixture The wires must not come into conta...

Page 5: ...u is accessed by pressing the Mode Esc button Browse through the submenu by pressing Up or Down Press the Enter button in order to select the desired menu You can change the selection by pressing Up o...

Page 6: ...board To set the pan to reverse Press the MENU until it shows RPOF Use the UP DOWN buttons show RPON press ENTER to confirm To set the tilt to reverse Press the MENU until it shows RTOF Use the UP DOW...

Page 7: ...en Fade delay close Select built color on Color change in pulse Color change Color change in fade Built in mode 1 Sound mode 15 0 1 20 21 40 41 60 61 80 81 100 101 120 121 140 141 160 161 170 171 200...

Page 8: ...R255 G255 B234 W255 16 0 9 10 19 ID effect No function ID 1 to ID25 per each 10 DMX value TECHNICIAL SPECIFICATIONS Model SIDIUS LED 368 Z Voltage 110V 250V 50 60Hz Power consumption 380W LED 36x8pcs...

Page 9: ...dad y notas de advertencia escritas en este manual del usuario Importante Los da os causados por no seguir este manual del usuario no est n sujetos a garant a el distribuidor no aceptar responsabilida...

Page 10: ...por la cabeza del proyector El mecanismo podr a da arse Al elegir el lugar de instalaci n aseg rese de que el dispositivo no est expuesto al calor extremo el polvo o la humedad No debe haber ning n ca...

Page 11: ...ementos altamente inflamables alrededor art culos de decoraci n cortinas etc a una distancia inferior a 0 5 m Los cables no deben entrar en contacto entre s de lo contrario el dispositivo podr a no fu...

Page 12: ...en deseado Puede cambiar la selecci n pulsando Up o Down confirmar cada selecci n pulsando la tecla Enter Para salir de cada modo seleccionado pulse la tecla Esc Las funciones proporcionadas se descri...

Page 13: ...a del ltimo dispositivo de la cadena consistente en una resistencia de 120 ohms entre los pines 2 y 3 Configurar la inversi n del eje Tilt Pressione MENU hasta mostrar RTOF Use las teclas UP y DOWN ha...

Page 14: ...60 161 170 171 200 201 205 206 210 211 215 216 220 221 215 226 230 Color incorporado El canal 14 debe tener un valor entre 91 210 Sin funci n R255 G B0 W0 R G255 B0 W0 R0 G255 B W0 R0 G B255 W0 R G0 B...

Page 15: ...55 G255 B234 W255 16 0 9 10 19 Efecto ID Sin funci n ID 1 a ID25 por cada 10 valores de DMX ESPECIFICACIONES TECNICAS Modelo SIDIUS LED 368 Z Alimentaci n 110V 250V 50 60Hz Consumo 380W LED 36 LEDs de...

Page 16: ...EQUIPSON S A Avda El Saler 14 Pol Ind L Alter 46460 Silla Valencia Spain Tel 34 96 121 63 01 Fax 34 96 120 02 42 www equipson es support equipson es...

Reviews: