4.1.2 Brick
4.1.3 Wood
Solid brick
Certification
EN 795 : 2012 class A1
Screws
NIRO M10 A2-80
ø 10 x 160mm
Drill
Masonry drill
ø 12mm
Setting depth in the load-bearing
subsurface
≥
140mm
Quality and installation base
≥
35 N/mm²
Composite mortar
Würth WIT-VM250, Fischer FIS AB
300T, Hilti HIT-HY 170
Remarks
BClean the boreholes with a perforated
brush and blow them out
Distance from edge
≥
200mm
Installation base
Drilled holes in the load-bearing brick
Deformation
Maximum expected deformation due to
a fall from a height
≤
50mm
Permissible installation positions
Number of users: 1 person
14
15
Solid wood
wall/ceiling
Certification
EN 795 : 2012 class A1, TS 16415 : 2013
Screws
Stainless-steel wood screws
NIRO A2-80, ø 10 x 100mm
Drill
Wood drill bit
ø 6mm
Setting depth in the load-bearing
subsurface
≥
80mm
Quality and installation base
C24 (S10),
≥
CLT 100
Remarks
Pre-drill holes
ø 6mm / 60mm deep
Distance from edge
≥
50mm
nstallation base
Drill holes in solid wood
Deformation
Maximum expected deformation due to
a fall from a height
≤
50mm
Permissible installation positions
Number of users: 1 person
Number of users: 2 persons