10

Models

Available 

series*

Chamber sizes

Max. 

film 

width

Machine weight

Power 

supply

Consump-

tion

(Max/ 

Average)

Machine dimensions 

axbxcxdxe (mm/inches)

Packed 

dimensions 

axbxcxdxe 

(mm/inches)

M

ax. 

Capacit

y

Net

Crated

COMPACK 4500-i

Code: Y12 001 1022

MG

450x320x250mm

17”x13”x9”

400mm

15”

80 kg

176 lbs

112 kg

246 lbs

230V,

15 Amps 

1 Phase

3,4/1,9kW

1085x615x1135x865x270

43”x24”x44”x34”x10”

1200x800x800

47”x31”x29”

8-10 packs/min

%20 fast

er in MC model

COMPACK 5800-i

Code: Y12 001 1042

MG-MC

580x440x250mm

22”x17”x9”

530mm

21”

109 kg

240 lbs

144 kg

317 lbs

230V

19 Amps

1 Phase

4,4/2,4kW

1227x745x1135x865x270

48”x29”x45”x34”11”

1200x800x800

47”x31”x29”

COMPACK 7000-i

Code: Y12 001 1062

MG

700x540x250mm

27”x21”x9”

650mm

25”

146 kg

321 lbs

196 kg

432 lbs

230V

22 Amps

1 Phase

4,9/2,7 kW

1499x859x1133x885x270

59”x34”x45”x34”x11”

1740x1040x800

68”x41”x31”

COMPACK 7000-i

Code: Y12 001 1062

MG

810x640x250mm

31”x25”x9”

750mm

29”

158 kg

348 lbs

209 kg

460 lbs

400V

27 Amps

3 Phase

6,2/3,5 kW

1800x980x1135x880x270

79”x38”x45”x34”x11”

1800x1040x900

71”x41”x35”

* ST:

 Standard series without magnetic hold down, 

*MG:

 Magnetic hold down series, 

*MC:

 Automatic discharge series

* Color:

 RAL 7035 Light gray

Warranty: 

One year on non-wearable parts

Technical Specifications

Summary of Contents for COMPACK 4500-i

Page 1: ...Tel 78123632021 info rospol com www rospol com SHRINK WRAP MACHINES for compack i series Maripack Compack i 5800...

Page 2: ......

Page 3: ...fety information 5 Contents of your package 5 Your machine 6 Mounting the legs 6 Control panel 7 Getting prepared Loading the film Sealing Shrinking Magnetic hold down 9 Periodic care 10 Technical spe...

Page 4: ...into circulation by us In case of alteration of the machine not agreed upon by us this decleration will lose its validity Description of the machine machinery part Machine Type Serial Number Applicab...

Page 5: ...o covers the repairing of the machine If the repairing is carried out in the client s plant the list price for service cost is invoiced to the client which is issued by the manufacturer The defected p...

Page 6: ...supply Plug in the machine to an appropriate voltage as shown on page 15 16 Check if the power supply is correct for the necessary connection given in the electrical diagram in this manual Do not tou...

Page 7: ...ealing blade 1 Pcs Allen key to screw conical film holders 1 Pcs Metal legs with casters 4 Pcs Your Machine Legends 1 Control panel 2 Transparent hood 3 Handle 4 Main body 5 Film holding bar 6 Working...

Page 8: ...s that the machine is ready to run operate 3 F mode indicates the FAN ON mode To disable the FAN and proceed with SEAL ONLY mode push the OK button 4 Indicates the actual room temperature Figure 2 Fig...

Page 9: ...loading the film when mounting the loaded bar make sure that the opening side of the film faces the front side of the machine device Pull the working plate the plate which slides back and forth towar...

Page 10: ...ring this operation the fan won t work You can wrap the package without shrinkage To enable or disable the FAN ON OFF mode just push the OK button Figure 4 number 3 Shrinking The fan and the blade wil...

Page 11: ...ransparent hood with a wet cloth Avoid using any chemicals to remove the dirt which may harm the hood Check if the teflon tape on the hood is damaged If so replace it with the supplied spare one This...

Page 12: ...09 kg 240 lbs 144 kg 317 lbs 230V 19 Amps 1 Phase 4 4 2 4kW 1227x745x1135x865x270 48 x29 x45 x34 11 1200x800x800 47 x31 x29 COMPACK 7000 i Code Y12 001 1062 MG 700x540x250mm 27 x21 x9 650mm 25 146 kg...

Page 13: ...ge 15 or 16 Replacement of the cutting blade Cutting blade can be broken in time In order to change it follow the steps below CAUTION Foryoursafetyunplugyourunitbeforeanyserviceaction Andmakesureifthe...

Page 14: ...l panel as shown in Figure 4 It is recommended to start with lower temperature to obtain a good shrink wrap Make sure that the metal flap on the heating room is opening properly at each operation If t...

Page 15: ...011 Y01 007 0011 Y01 007 0011 Casters EP01 ZKC 075 C Y01 010 0011 Y01 010 0011 Y01 010 0011 Linear bearings for film holder box D Y11 001 3422 Y11 001 3422 Y11 001 3422 Perforater male E Y11 001 3420...

Page 16: ...fan F Y11 001 3472 Y11 001 3462 Y11 001 3482 Ceramic infill group G Y11 001 3410 Y11 001 3410 Y11 001 3410 Corner insulating part for blade H Y11 002 0020 Y11 002 0020 Y11 002 0020 Magnetic selenoid a...

Page 17: ...14 N OUT4 OUT1 24V 24V CONTROLLER u OUT2 48VAC Cutting Blade DV AnEN ION nllS DOCUMENT CONTAINS PROPRIE ARY DATA OF wr lusuRE REPRODUC ON OR USE OF ANY PART OF ntlS DOCUMENT W U WR EN PER ISSION 24VD...

Page 18: ...0 0 0 0 SUPLY 0 0 0 0 0 0 0 0 0 0 0 D OPERATOR PANEL LAYOUT PRODUC INDEX L AnEN ION nllS DOCUMENT 4 Drawnby 11 002 0060 Edition Date CONTAINS PROPRIE ARY DATA OF MARIPAK Date 29 01 2007 15 01 2010 NO...

Page 19: ...Packaging lndustrial Equipment Ltd...

Reviews: