background image

SYSTEM DIAGRAM 

Check the box thoroughly for all parts listed for the type of unit purchased. All units come standard 
with a Garden Hose Fitting. If the feed water (faucet or laundry sink) does not have ¾” garden hose 
threads, you will need to purchase a Feed Water Adapter, or a Faucet Coupler. These and other sold 
separately plumbing parts are available at MarineDepot.com or your local hardware store. 

The pressure gauge (Figure A; included with Advanced models) will allow you to monitor the pressure 
of the system and make sure that the filter is receiving sufficient water pressure to operate efficiently 
as well as monitor your pre-filters. It will indicate, via a drop in pressure, when the sediment and 
carbon block filters are clogged and need to be replaced. 

The Dual or Triple TDS meter (Figure A; included with Advanced models) is used to monitor the 
condition of the TFC membrane and DI cartridge. 

Flush Valve kit (Figure A; included with Advanced models) purges the TFC membrane and helps to 
extend membrane and DI cartridge life. We recommend flushing your membrane for 30 seconds 
before and after each use.

STORAGE 

When the unit is not in use, it is important to keep the TFC membrane hydrated. The TFC membrane 
must not be allowed to dry out. Keep the unit in a cool location and keep all inlet and outlet lines above 
the unit so the water will remain in the unit. If the RO (or RO/DI) system will not be used for more than 
4 weeks, remove the TFC membrane and store it in a refrigerator inside a Ziploc bag filled with a small 
amount of purified water. Do not allow the RO (or RO/DI) unit to be exposed to freezing conditions or 
temperatures above 100°F. 

Figure A:

 

Pressure gauge - TDS 

Monitor - Flush Valve

Figure B-3:

 

KleanWater 4-Stage Advanced 

RO/DI System

Figure B-1: 

KleanWater Basic RO System

Figure B-4: 

Marine Depot KleanWater 

6-Stage Economy RO/DI System

Figure B-2: 

KleanWater 4-Stage Economy 

RO/DI System

Figure B-5 

KleanWater 6-Stage Advanced 

RO/DI System

3

Visit marinedepot.com/kleanwater

Summary of Contents for KleanWater RO

Page 1: ...User s Manual www marinedepot com customercare marinedepot com 1 800 566 3474 ...

Page 2: ...rbon Pre filter The second stage of filtration is a carbon pre filter select models feature two carbon cartridges This filtration step removes organics chlorine chloramine and other chemicals from the feed water that can damage the membrane For the most effective chloramine removal we recommend replacing the filters with our Chloramine X GAC Carbon Filters once your current filters are exhausted R...

Page 3: ...ge Flush Valve kit Figure A included with Advanced models purges the TFC membrane and helps to extend membrane and DI cartridge life We recommend flushing your membrane for 30 seconds before and after each use STORAGE When the unit is not in use it is important to keep the TFC membrane hydrated The TFC membrane must not be allowed to dry out Keep the unit in a cool location and keep all inlet and ...

Page 4: ... will be space needed below the unit to accomplish regular maintenance of the filter system such as pre filter removal Additional hardware and or plumbing parts are available at MarineDepot com or your local hardware or plumbing supply stores For RO DI systems you will need to remove the DI cartridge from the far left chamber s before turning on the cold water supply Place the yellow waste water l...

Page 5: ...se osmosis membranes are packed with an anti bacterial agent to keep them sterile prior to use This agent should be flushed away to avoid human or animal consumption Turn on the water once again and allow the unit to run for 30 minutes to flush out the anti bacterial agent For RO systems allow the system to flush completely for 30 minutes and discard the initial batch of water produced Once flushe...

Page 6: ...ing The Kleanwater Economy RO DI is available in 4 stage shown above and 6 stage options Accessories and additional plumbing parts are available separately at MarineDepot com Carbon Carbon Sediment Waste water to drain Product Water Feed water from garden hose adapter Economy RO System Diagram TFC Membrane Housing 6 Questions Call 1 800 566 3474 ...

Page 7: ...rs are clogged and need to be replaced The Flush Valve is used to flush your TFC membrane for 30 seconds before and after each use Simply open the valve so the knob is parallel to the tubing to flush your system After thirty seconds close the valve and begin collecting RO DI filtered water The TDS Meter includes two probes inserted into white tee fittings These tee fittings w probe will need to be...

Page 8: ... flow restrictor dried up or damaged TFC membrane install new TFC membrane Slow water production clogged pre filters install new pre filters low water pressure 45 PSI install booster pump or use higher output TFC membrane low water temperature install booster pump or use higher output TFC membrane hard water or high TDS install booster pump or use higher output TFC membrane damaged TFC membrane in...

Reviews: