Caution

To identify a gas leak, a peculiar scent was added to Natural and Liquid Propane 
Gas. If you are unfamiliar with the smell of Natural or Liquid Propane Gas, please 
consult your local gas supplier. They maybe some conditions that can cause the 
scent to diminish in intensity, making it difficult to identify a gas leak. 

- Liquid Propane Gas is denser than air and will amass first on lower areas making it 
difficult to detect at nose level.

- Before attempting to light the unit uses a soapy solution to check all gas fittings 
and  connections.    Bubbling  at  a  connection  indicates  a  gas  leak  that  must  be 
corrected.   Also make sure to smell for gas leaks. When smelling to detect a gas 
leak, be sure to sniff near the floor also.

-  Installing  Gas  detectors  is  highly  recommended  for  both  Liquid  Propane  and 
Natural  Gas  applications.  Please  refer  to  local  laws,  regulations  and 
manufacturer's recommendations in order to correctly install a gas detector in your 
house.

- Units using Natural gas are different from Liquid Propane models.  For your safety 
do not uses natural gas with Liquid Propane Unit and vice versa.

- You should never attempt to convert the water heater from Natural Gas to Liquid 
Propane. 

-  Do  not  connect  the  unit  to  a  fuel  type  that  is  not  in  accordance  with  the 
specifications to avoid possible, fire, equipment damage or personal injury.  

Other Precautions

1.

 This unit only uses Liquid Propane Gas.

2.

 Please do not place hands or other objects on top of the heater or the exhaust 

gas pipe, it is very hot.  

3.

 If the smell of gas is detected, turn off the gas valve at the tank immediately. 

4.

 Do not use in strong wind conditions.

5.

 Do not leave unattended.

6.

 Do not over tighten the gas regulator connection to the unit with a wrench.  This 

may break the gas inlet.

The MAREY PORTABLE liquid propane gas water heater is capable o delivering 
1.4 GPM (gallons per minute) - 5 (LPM liters per minute). This unit has a standard 
1/2“NPT pipe fittings and an adapter for using a standard garden hose for inlet 
water supply.

Ignition is automatic and powered by 2 “D” cell batteries (not included).   Burners 
come on when water pressure is more than 5 PSI, and off when the water is shut off.

A shower nozzle with multiple spray patterns is included.
 
For gas supply a standard 20 pound propane cylinder (not included) is required.   
This is similar to the gas tanks used with outdoor grills. A regulator with hose is 
furnished with the heater.

An additional safety feature of an automatic 20 minute shutoff timer that is reset 
each time operation stops or the shower head is turned off and back on.

1- Portable
2 - ODS Device
3 - Temperature Controller
4 - Sensor Pin
5 - Gas Adjusting Valve
6 - Solenoid Valve
7 - Pulse Generator
8 - Gas inlet
9 - Hot Water Inlet
10 - Wall Mounting Holes
11 - Back Plate
12 - Heat Exchanger
13 - Ignition Pin I
14 - Ignition Pin II
15 - Burner
16 - Water Adjusting Valve
17 - Micro-Active Switch
18 - Cell Box
19 - Release Device
20 - Water Inlet

2
3

4

5

6
7

8

10

11
12
13
14
15
16

18

9 19

20

17

1

Perfect for Camping!

Summary of Contents for GA5PORT

Page 1: ...PORTABLE TANKLESS GAS WATER HEATER INSTRUCTION MANUAL Keep this manual with you after your unit has been installed you may need it for further technical information GA5PORT MODEL GAS WATER AGUA...

Page 2: ...nderstand the safety and installation manual in its entirety before you attempt to install your new Portable tankless water heater If you are not familiar with basic plumbing and electricity we highly...

Page 3: ...Propane Gas 2 Please do not place hands or other objects on top of the heater or the exhaust gas pipe it is very hot 3 If the smell of gas is detected turn off the gas valve at the tank immediately 4...

Page 4: ...pe 8 Attach the gas regulator by hand pressure to avoid any broken part and make sure the gas tank valve is off Before hooking the gas valve connection make sure it is completely in the off position B...

Page 5: ...work Check that the incoming is on the far right and the outgoing is in the middle 4 The On Off switch should be with the sign pushed down ADJUSTMENT On the bottom of the unit you will see 2 oval hol...

Page 6: ...s of 5 145 PSI If your house water pressure is below the minimum the unit will not activate You will need a sustained water pressure of approximately 40 60 PSI for adequate use Dear Customer You have...

Page 7: ...is not covered under warranty The warranty seal should be intact Original purchase receipt will be required Your unit should be registered in the warranty program within 30 days of purchase TO REQUEST...

Reviews: