Marey ECO110 Instruction Manual Download Page 14

5. Before beginning any work on the electric installation, be sure that the main breaker

panel switch is OFF to avoid any danger of electric shock. All mounting and plumbing

must be completed before proceeding with electrical hook-up.

OPERATING INSTRUCTIONS

1. Turn on the circuit breaker to bring electrical power to the unit.

2. Open the water faucet for a few minutes until the water flow is continuous and all the

air is purged from the water pipes. The unit must operate after the breakers are turned on

3.After the unit is supplied with power, a beep sound can be heard and LED lights appear

for 2 seconds; if there is no other display, the appliance keeps standby.

4. Press         to turn ON/OFF the appliance. When the unit is ON, LED lights show the

actual outgoing water temperature. When the appliance stops working, after 5 seconds,

the screen switches on the screen saver. The display screen light will be off. If somebody

touches the screen, the Iight will be on again.

5. Press

             

and            to adjust the outlet water temperature. Temperature setting

range is 30-52°C/ 86-125°F.

- If the unit has been paused, you may initially get a short burst of very hot water when

you turn it on again. Please run the water through for a few seconds to let the temperature 

settle down. Please check the hot water with your hand before taking a shower.

- If the unit is not used in winter, drain out the water completely so that the heater does

not freeze.

- Please clean the inlet filter and the shower periodically in order to keep a proper water flow.

6. Press

          

to change the temperature display between Fahrenheit and Celsius degrees.

7. There is an automatic memory function to avoid repetitive operation. When you turn on the

appliance, the default setting temperature will be the same as last time setting.

14

Summary of Contents for ECO110

Page 1: ...is manual with you after your unit has been installed you may need it for further technical information ECO110 ELECTRIC TANKLESS WATER HEATER INSTRUCTION MANUAL USA 855 627 3955 PR 787 727 0277 www ma...

Page 2: ...this safety and installation manual in its entirety before you attempt to install your new ECO11O tankless water heater as it contains important safety tips and instructions Please carefully read all...

Page 3: ...ONS PRODUCT FEATURES PRODUCT ADVANTAGES TECHNICAL SPECIFICATION AND INSTALLATION REQUIREMENTS PRODUCT INNER STRUCTURE INSTALLATION GUIDELINE INSTALLATION DIAGRAM OPERATING INSTRUCTIONS TROUBLE SHOOTIN...

Page 4: ...ck up wrench on inlet and outlet fittings flat sides of fittings are located behind front cover The cold water inlet is on the right side it should be preceded by a high pressure discharge valve and a...

Page 5: ...y water by disconnecting the water lines Leave the water lines disconnected until you intend to use the water heater This is not a do it yourself task Failure to have this appliance installed by a lic...

Page 6: ...ay all plumbing paste or residue in them 10 The heating chamber is covered by composite nano insulation material it is natural if there might be a bit of smelI or green blue smoke when the unit is use...

Page 7: ...he temperature drops to the set temperature 4 Malfunction of sensor when there is malfunction of the temperature sensor the heater stops working and displays E3 5 Conversion between degree Fahrenheit...

Page 8: ...ng Pressure Water Connections Installation Temperature Setting Dimensions Weight PRODUCT CODE ECO110 GPM ECO110 220V 240V 11kW 50A 45 8A 6 AWG 0 53 GPM 2L min 5 PSI 85 PSI NPT Mounted Vertically Digit...

Page 9: ...oper voltage rating Ground must be brought to the ground at the circuit breaker panel 4 This appliance MUST be permanently connected to the fixed circuit breaker If you do not use the heater please sw...

Page 10: ...D INSTALLATION ON THE WALL Locate an appropriate place on a section of the wal I as mentioned above Fig 01 Front and back of the appliance Fig 02 Remove screws which are fixed at the front and back co...

Page 11: ...ect the cable to the terminal blocks and please notice the guidance logo below the terminal blocks Fig 04 Connect PCB row line of the front cover to PCB of the back cover and then fix the front and ba...

Page 12: ...the wall according to the following picture then drill three holes of 6 00mm diameter Put expansion bolts in the holes and then screw the self tapping screws into the expansion bolts Fig 06 Fix the a...

Page 13: ...er seal rings at the connections When all water connections are completed check for leaks and take the necessary actions before proceeding Electrical connections 1 AIl electrical work must comply with...

Page 14: ...e appliance stops working after 5 seconds the screen switches on the screen saver The display screen light will be off If somebody touches the screen the Iight will be on again 5 Press and to adjust t...

Page 15: ...ber washer A Connect power to the unit B Change LCD C Connect LCD to the PCB Board A Open valve to get water B Open valve to get pressure C Change key or PCB A Set a lower temperature B Open valve big...

Page 16: ...787 727 0277 PUERTO RICO Please feel free to contact us if you have any questions about our products warranty service or if you need assistance installing a unit We also strive for continuous improve...

Reviews: