Fig. 07:
Connect the water pipe to the water inlet and water outlet connections, please
remember to install the rubber seal ring.
Water connections
1. All water pipes must comply with national and applicable state and local water pipe codes.
2. The unit should be connected directly to the main water supply. Flush the pipe with water to
remove any debris or loose particles.
3. It is required to use 1/2" NPT water connections to fit the models on EC0110.
4. Please remember to install rubber seal rings at the connections. When all water connections
are completed, check for leaks and take the necessary actions before proceeding.
Electrical connections
1. AIl electrical work must comply with national and applicable state and local electrical codes.
2. The unit must be connected to a properly grounded dedicated branch circuit of proper
voltage rating.
3. EC0110 can be connected to a single circuit, using a supply cable protected by a double
pole breaker.
4. While connecting the cable to the terminal blocks, please make sure the metal wire ends
and the terminal blocks fit completely. Then tighten the screws up to make sure the full
current can go through.
13