Maretron SH-003 Installation Instructions Download Page 3

SMOKE DETECTOR WIRING W/CIRCUIT MONITORING

Note:

These wiring instructions show connections to channel 'SW1' of the SIM100 however,
connections could be made to other channels of the SIM100 using the same method.
The SIM100 can support up to 6 detector areas.

Detector Dimensions W/Base:     3.96" (101 mm) Diameter, 2.63" (67 mm) Height

Sounder Dimensions W/Base:     3.94" (100 mm) Diameter, 3.15" (80 mm) Height

EOL Relay Dimensions:               3.44" (87 mm) L x 3.44" (87 mm) W x 1.63" (41 mm) H

8K Ohm

EOL

RESISTOR

EOL RELAY

LED (-)

SW6B

SW5A

SW6A

SW5B

SW4B

SW4A

SW3B

SW3A

SW2B

SW2A

SW1B

SW1A

12

9

11

10

8

7

6

5

4

3

2

1

SIM100

SIM100 Input Description:

8K Ohm......System OK
Closed........Alarm Signal
Open..........Broken Circuit /

Loss of Power
(Maintenance Required)

COM

IN(+)

1 (C)

3 (N/O)

(+)

SOUNDER

DETECTOR

IN

OUT

RELAY

(-)

(+)

N/C

COM

N/O

E

N/C N/O COM

E

(-)

4

2 (N/C)

OUT (+)

(-)

(+)

24V

DC

Reviews: