10
Mareli Systems
3.5 Air intake
Suction pipe or air intake is placed in the back and has a circular section with a diameter of 48 mm.
The combustion air can be aspirated:
•
From the camera, as long as it is near an air intake communicating with the outside wall hav-
ing a minimum area of 100 cm2, properly positioned and protected by a grid.
•
Or by connecting directly outside with a suitable tubing having an inner diameter of 48 mm
and a maximum length of 1.5 M.2
4. Cleaning
Cleaning the fireplace should be done only when cold. The cleaning of the combustion chamber
must be carried out daily. For this purpose, make sure the fireplace has ceased operation and is
completely cold. Pull up the combustion pot and remove it from the stove and then clean it from
soot. When removed fuel pot at the bottom of the combustion chamber opens a hole designed for
the accumulated ash. Collect ashes in the ashtray and return fuel pot in place and then close the
door. The fireplace is ready for operation.
Cleaning of flues and chimneys are conducted once every 1.5 tons of fuel used
Once clean audits and close the cleaning lid. Check that the bolts are tightened well. Every time
you open check for violations of the isolation seal. If this happens do not use the product until the
isolation seal is repaired.
Капак за почистване
2
3
4
1
Summary of Contents for PB 13
Page 13: ...13 Mareli Systems COLD WATER HOT WATER CHIMNEY OUTLET AIR INLET...
Page 22: ...22 Mareli Systems...
Page 23: ......