MARcus TD-WI 1 Operation Manual Download Page 4

-    - 

 

 

connection of RS232 

Plastic housing connect to Din9                Pin 2    RXD    Pin3    TXD    Pin5    GND 

              Stainless steel housing on PCB                                  TXD      GXD      RXD

 

 

SECTION 2 KEY DESCRIPTIONS 

 

SOFT POWER ON/OFF Key 

Power on/off the indicator. 

 

ZERO Key               

1) When self-checking, Press ZERO Key to enter parameter setting;   

2) Set the zero point for all-subsequent weighing;   

3) Move the cursor to change the digit when setting parameters or other functions. 

 

TARE Key   

         

1) When self-checking, Press TARE Key to enter fast calibration; 

2) Tare the scale. Store the current weight in memory as a tare value, subtract the tare value from the weight and 

shows the net weight. Entering a value using the keypad will store that value as the tare value;   

3) Cycle through the functions or increase the active digit when setting value for parameters or other functions. 

 

MOD/ ESC Key 

 

1) Enter / Cancel the counting mode from weighing mode when 

“F3 KEY”=1;   

2) Accumulate and print when 

“F3 KEY”=2;   

3) 

“Hold” Function keep and cancel when “F3 KEY”=3; 

4) Enter pre-tare value when 

“F3 KEY”=4; 

5) Parameter setting for animal weighing when 

“F3 KEY”=5; 

6) Cancel or quit from the operations. 

 

FUN Key

     

1) Select or enter the function and save the setting values of parameters;     

2) View unit weight, counts and total weight when counting mode (

“F3 KEY”=1); 

3) View nos. of accumulated weight and total weight when 

“F3 KEY”=2;   

Summary of Contents for TD-WI 1

Page 1: ...TD WI 1 WEIGHING INDICATOR Operation Manual ...

Page 2: ...r on off 3 3 2 Functions and parameters setting 3 3 3 Zero the scale 3 3 4 Tare the scale 4 3 5 Parts counting KEY 1 4 3 6 Accumulation KEY 2 5 3 7 Holding the weight KEY 3 5 3 8 Presetting tare value KEY 4 5 3 9 Animal weighing KEY 5 5 3 10 Check weighing 6 3 11 Print KEY 2 6 SECTION 4 FUNCTIONS AND PARAMETERS 7 SECTION 5 RS 232 OUTPUT 8 SECTION 6 ERROR CODES 9 ...

Page 3: ...S 232 Output Stabilisation time 1 second typical Operating temperature 0 C 50 C 32 F 104 F Load cell drive voltage 5V Max 150mA Other function Real time clock and units conversion Load cells Up to eight 350 ohms cells 1 3 Installation The weighing indicator should be sited in a location accuracy would not be degraded Avoid extremes of temperature Avoid unstable power sources Do not use near large ...

Page 4: ...act the tare value from the weight and shows the net weight Entering a value using the keypad will store that value as the tare value 3 Cycle through the functions or increase the active digit when setting value for parameters or other functions MOD ESC Key 1 Enter Cancel the counting mode from weighing mode when F3 KEY 1 2 Accumulate and print when F3 KEY 2 3 Hold Function keep and cancel when F3...

Page 5: ...k state When self checking press UNIT Key to enter unit conversion coefficient setting 3 3 Zero the scale Press ZERO Key to set the zero point from which all other weighing and counting is measured Usually this will only be necessary when the platform is empty When the zero point is obtained the ZERO indicator is ON The scale has an automatic re zeroing function to account for minor drifting or ac...

Page 6: ... size of 10 parts Change the sample size by pressing the TARE Key the display will cycle through the options 10 20 50 100 200 Counting Press FUN Key when the number matches the sample size Remove samples from the container and place the desire parts for counting purpose Display will show the number of parts pcs Viewing the Unit Weight Nos of Counts Total Weight Press FUN Key to cycle through Unit ...

Page 7: ...on the scale meets or exceeds values stored in memory The memory holds values for a high limit and a low limit Check range Set hi limit and low limit as different values and hi limit value is larger than low limit value Check key point Set hi limit and low limit as same value Check mode Setting the parameter Select F4 CHK to enter check mode Press FUN Key to enter and sub select BEEP 1 BEEP 2 or B...

Page 8: ...s only a dot at the last digit will be displayed When dot weight changing can wake up the indicator SLP 5 10 15 Same as SLP 3 F2 BK Backlight mode setting For LCD version Auto mode The backlight will distinguish when no action is taken during a certain time Off mode The backlight is off all the time On mode The backlight is always on F3 KEY MOD Key setting KEY 1 To set the MOD Key for counting gro...

Page 9: ...ows XXXXXX Set it to be the weight of the weigher you want to put on Press FUN Key to confirm and it will show LoAd Put the calibration weigher on the platform and press FUN Key after the STABLE indicator is on Indicator will go to weighing state The calibration is finished P9 INT Initialize the memory to ex work state P10 RS Communication mode This option is used for the RS232C serial port mode s...

Page 10: ...same as continue output The only difference is After weighing when take away the goods display returns to zero then transfers Data Format for normal weighing operations Examples as follow 2000 02 11 21 21 58 No TARE NET GROSS TOTAL 001 0 000U1 0 034U1 0 034U1 0 034U1 DATE 2000 02 11 TIME 21 26 56 NO 001 TARE 0 000kg NET 0 076kg GROSS 0 076kg DATE 2000 02 11 TIME 21 27 41 NO 002 TARE 0 125kg NET 0 ...

Page 11: ...om the scale Err 1 Err 2 Date and Time not right Reset again Err 4 Zero Setting Error The scale was outside the normal zero setting range either when it was turned on or when the ZERO Key was pressed Remove weight from the scale and try again Use the TARE Key to set the display to zero value ...

Reviews: