background image

 

 

 

User Manual

 

 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 

 

TD 2014    Series Weighing Controller 

Applications: Electronic platform scale, weighing scale, etc. 

Summary of Contents for TD 2014 Series

Page 1: ...User Manual TD 2014 Series Weighing Controller Applications Electronic platform scale weighing scale etc ...

Page 2: ... Size 95 48 110 mm Weight 0 5 kg Signal output 4 20 mA analog output Options a Opto isolated RS232 or RS485 b 6 relay outputs with 2 opto isolated inputs that can be used to control the output of relay 1 and 2 2 Model Number TD 2014 0 No interface 1 Optical isolated RS232C 2 Optical isolated RS485 AC AC 110 220V 50 Hz available for XK315A2 6A series only DC DC 9V 1A adapter A Basic model with 4 20...

Page 3: ...ntinuous ASCII regular data output if weight is 123 45 the output is 123 45 3 Adr 01 98 data output using ModBus protocol 8 Operation 1 Turn on the indicator it displays the version number and checks the LED from 0 to 9 2 Zero When the weight is stable between 2 FS press 0 zero the display and 0 is on When the zero reference is 2 FS it displays HHHHHH When the zero reference is 2 FS it displays LL...

Page 4: ... to select filter Press AUtP00 Set zero trace range and zero at start range AUtP 00 no zero set at start zero trace range is 0 4d AUtP 10 zero at start range is 20 FS zero trace range is 0 4d AUtP 20 zero at start range is 20 FS zero trace range is 0 8d AUtP 30 zero at start range is 20 FS zero trace range is 1 2d AUtP 40 zero at start range is 20 FS zero trace range is 1 6d AUtP 50 zero at start ...

Page 5: ...a combinations of T and 0 to change the magnification Press rAtE 1 Set AD sample rate 0 10 times second 1 40 times second 2 250 times second Press Or T rAtE 2 Press a combinations of T and 0 to change the sample rate Press 0 00 Save all parameters 10 Calibrations Operation Display Descriptions Press 000000 Go to Calibrations and Configurations menu and enter password 002003 Press Or T 002003 To en...

Page 6: ... 000000 Go to Set Point menu and enter password 110906 Press Or T 110906 To enter password 110906 Press to move blinking digit to the right Press T to increment blinking digit Press 0 to decrement blinking digit Press A1 Set point 1 for relay 1 Press 000150 Press to access set point 1 Press Or T 000200 Press a combinations of T and 0 to set point A1 to 000200 Press A2 Set point 2 for relay 2 Follo...

Page 7: ...g Press En o5 Set the output of 5 relay Follow step 14 to 16 to change relay output setting Press En o6 Set the output of 6 relay Follow step 14 to 16 to change relay output setting Press 0 00 Save set points 13 Software version VER2 01 packing scale VER2 02 3 speed rating scale VER2 03 check weighing VER2 04 2 materials 2 speed batching scale VER2 05 3 materials 2 speed batching scale VER2 06 4 m...

Page 8: ...7 maintenance and calibration facilities 16 Relay output ...

Reviews: