Marco FILTRO SHUTTLE 1000650 Instructions Download Page 3

1900062   

                                                          REV.2 

Page 3 of 4

 

Note  :  Default  settings  may  vary  depending  on  local  connection  factors,  if  required  recalibration  can  be 
carried see Setting Brew Water Volumes/Water Flow Times section.  

 
OPERATION:  
 

  When the machine has enough water to brew coffee and is at the correct 

temperature, the Ready To Brew LED will glow.  A brew can be selected at this 
point. 

  Place single filter paper into brew basket, use the 2 wire flaps to hold the filter 

paper in place. Add the required weight of coffee. 

  Slide Brew basket into the guiderails and push fully home. 

  Ensure your Urn is in place under the basket and that the hole in the basket is 

lined up with the centre of 

the urn’s inlet funnel. The Filtro Shuttle is designed to 

accommodate the Marco Urn, Part number “1700174 Insulated Urn 6L Shuttle”  

  Select the correct brew on the control panel by pressing the required Brew 

Button. Press the switch until the yellow LED illuminates. N.B. If you make a 
mistake press the Power Button to turn the machine off. Wait 3 seconds and 
turn back on again. Select the correct brew. 

  After brewing, remove the filter paper with the spent grinds when the basket can 

freely move and dripping has stopped.  

  Once the brew is completed the brew basket will remain locked for a further 2 

minutes to allow the remaining water in the brew basket to filter through. This 
basket lock will be an audible click and is linked to the Brew Button LED. 

 

Setting Brew Water Volumes/Water Flow Time 

With the Filtro Shuttle you may programme (Calibrate) each of the Brew Buttons to 
have different Water volume and Overall Brew time settings or to disable buttons.  
Contact [email protected] for more information. 

 

Pulse brewing mode: 

The Filtro Shuttle will operate in a Pulse Brewing mode. For more details about 
Pulse brewing mode contact [email protected] for more information.  
 

Troubleshooting

: The Power LED will indicate failures as follows. 

No of flashes  Symptom 

Action  required 

Water 

level 

below 

elements. 

May  take  10-15  minutes  to  fill  at 
low  pressure 

Check  water  pressure,  if  this  is  OK  -  call 
service  agent. 

Temperature  sensor  failure) 

Call  service  agent 

Water not  heating 

Call  service  agent 

Temperature  sensor  failure   

Call  service  agent 

Machine  not  filling 

Check  water  pressure.  If  this  is  OK  and 
the  machine  has  not  returned  to  normal 
operation  after  15  min 

–  call  service 

agent 

Reviews: