Marco Ecoboiler WMPB3 Service Manual Download Page 3

Service Manual  Ecoboiler  wallmount 1000671 100676 061010 

 

 

Page 3 of 18 

 

1. 

INTRODUCTION:  

 
The information provided in this manual is intended to assist in the installation and maintenance of 
the Marco 

Ecoboiler Wallmount Range

. Please read the instructions carefully to prevent accidents 

and ensure an efficient installation. 
 
This manual is not a substitute for any safety instructions or technical data affixed to the machine 
or its packaging. All information in this manual is current at the time of publication and is subject to 
change without notice. 
 
Only technicians or service providers authorised by Marco should carry out installation and 
maintenance of these machines.  
 
Marco accepts no responsibility for any damage or injury caused by incorrect or unreasonable 
installation and operation. 
 

2. 

SAFETY INSTRUCTIONS:  

 
 

 

Read all instructions. 

 
 
 

 

Do not operate any appliance with a damaged cord, plugs, or after the appliance 
malfunctions or has been damaged in any manner. 

 
 

 

Switch off at the mains (unplug or disconnect from outlet) and turn off the water supply 
when not in use and before cleaning. Allow to cool before removing components. 

 
 

 

The use of spares and accessories not recommended by Marco may cause damage and/or 
injuries. 

 
 

 

Do not use outdoors. Do not place on or near a hot gas or electric burner. 

 
 

 

Do not use the appliance for anything other than its intended use. 

 
 

 

Save these instructions. 

 
 
 
 
 
 
 
 
 
 

Summary of Contents for Ecoboiler WMPB3

Page 1: ...boiler WMT3 Ecoboiler WMPB3 SERVICE MANUAL Marco Beverage Systems Ltd 63d Heather Road Sandyford Industrial Estate Dublin 18 Republic of Ireland Ireland Tel 01 295 2674 Ireland Fax 01 295 3715 UK Tel...

Page 2: ...ning 6 3 7 Limescale 6 3 8 Cautions and Safety Tips 6 4 TECHNICAL DATA 4 1 General Description 6 4 2 External Arrangement 7 4 3 Internal Arrangement 7 4 4 Access to internal components 8 4 5 PCBs 9 4...

Page 3: ...orised by Marco should carry out installation and maintenance of these machines Marco accepts no responsibility for any damage or injury caused by incorrect or unreasonable installation and operation...

Page 4: ...derside o When the machine is plumbed from the rear connect right angled tailpiece to the inlet valve of the boiler again BSP o When the machine is plumbed from the underside connect non angled tailpi...

Page 5: ...calibration process the steps below should be followed 5 If the tactile switch is pressed too early and the temperature is set lower than desired the tester should simply repeat calibration 6 If the t...

Page 6: ...earthed Risk of flooding The hose supplied with this unit is non toxic food quality tested to 190psi However a hose is not a permanent connection It is therefore advisable to switch off boiler and cl...

Page 7: ...ed centre panel Top tank access Lid High Level Probe Assembly 2300463 Low Level Probe Assembly 2300463 PCB Ecoboiler Control 1600345 ELEMENT 2 4kW 230V 1500950 Valve inlet Solenoid 1502190 Overflow Tu...

Page 8: ...ol sufficiently 3 The removable Side Panels are fixed at the top of the machine 4 Unscrew with a Philips head screwdriver 5 Remove the panels in an upward and outward motion Reassembly To re attach th...

Page 9: ...lace 4 5 PCBs 4 5 1 PCB Layout Internal PCB Layout PCB Ecoboiler Control 1600345 Controls the heater switching Controls the water inlet switching Controls tank temperature temperature adjustment PCB E...

Page 10: ...Tab 2 Inlet Solenoid Tab 3 Neutral Tabs 4 Transformer 5 Mains Live In Tab 6 Relays Heater Switch the element 7 Heater Tab 8 On Off 2 way Connector Short circuited on this Ecoboiler machines power swit...

Page 11: ...via a flashing RED LED 4 Eco Mode On LED s 5 Eco Mode On Of Switch 6 5 way connector to PCB Ecoboiler LED connector 7 4 way connector to PCB Ecoboiler BUTTONS connector 4 6 TROUBLESHOOTING DIAGNOSTIC...

Page 12: ...this error is detected This is a recoverable error When the correct range of resistance is measured normal operation resumes Probable causes 1 The thermistor probe is unplugged from the 4way connecto...

Page 13: ...cooled by when the inlet solenoid valve is opened If the water pressure is within the specifications 5 50psi the inlet solenoid should not be on for more than a few seconds If this water temperature h...

Page 14: ...trol inputs into the PCB and are critical to the operation of the machine The wiring to these should be checked regularly and the probes themselves should be cleaned whenever the machine is serviced O...

Page 15: ...rain hose is located at the base of the machine which is accessible by removing right side panel Use ScaleKleen Marco part No 8000270 or similar Follow instructions carefully Remove lid located on the...

Page 16: ...Service Manual Ecoboiler wallmount 1000671 100676 061010 Page 16 of 18 4 9 Wiring Diagrams...

Page 17: ...Service Manual Ecoboiler wallmount 1000671 100676 061010 Page 17 of 18...

Page 18: ...PCB Ecoboiler Display 10L Rev 1 0 X X 1600691 Thermistor Assembly X X X X 2100279 Tap Hot Water X X 2301463 Level Probe Assembly X X X X 8000240 Urn Cleanser 800g Tub X X X X 8800121 Descale Box 6 Pac...

Reviews: