PRODUCT DESCRIPTION
Temperature:
min. -10 °C / max. +60 °C
Relative humidity:
max. 90 %
Warning:
the above indicated temperature ranges are applicable to all components of the
pump and these limits must be respected in order to avoid any possible damage or
malfunctioning.
The electric pump must be connected to a source of direct current (either battery or
transformer) with an amp rating of over 15A and 7,5A at nominal voltage of 12V and 24V
respectively. The pump must be protected by a suitable rated fuse.
The pump has been designed for discontinuous use. Under conditions of high operating
pressures (eg. with closed or blocked outlet, excessive length of the delivery circuit and/or
excessive pressure due to accessories), the pump can be subjected to elevated stresses
and overheating and therefore should not be used for prolonged periods under such
conditions.
ELECTRICAL CONNECTIONS
OPERATING CYCLE
AMBIENT CONDITIONS
TECHNICAL DETAILS
APPLICATIONS
There are numerous fields of applications for the pump, however only exclusively with
the allowed liquids mentioned:
- transfer of diesel fuel between tanks, refuelling of tractors and earth moving
equipment
- transfer of water
- transfer of light weight lube oils, antifreeze, etc.
CODE
TYPE
VOLT
FUSE
FLOW RATE
PRESSURE
WEIGHT
PCS x CART.
164 100 12
12
15 A
164 100 13
24
7,5 A
6
UP9
12 l/min
5 bar
2,7 kg
Self-priming electric pump for heavy duty with long running. The pumping elements are
made up of bronze gear drives which can possibly even run dry for brief periods.
Completely equipped with in-line filter on the inlet side.
A
B
C
D
E
F
E N G
7