![Marco 162 001 1B Instructions For Use Manual Download Page 4](http://html1.mh-extra.com/html/marco/162-001-1b/162-001-1b_instructions-for-use-manual_1726588004.webp)
ALLOWED:
FRESH WATER AND SEA WATER
WATER CONTAINING GLYCOLS
NOT ALLOWED: RELATED DANGERS
PETROL (GASOLINE)
FLAMMABLE LIQUIDS with PM < 55°C
LIQUIDS WITH VISCOSITY > 20 cSt
FOODSTUFF LIQUIDS
CORROSIVE CHEMICAL PRODUCTS
SOLVENTS
DIESEL FUEL
Due to limited weight and dimensions the pump does not require the use of any special
handling or lifting equipment. When handling manually, normal personal protective gear
should be worn (safety shoes with toe piece, etc.)
The pump is carefully packed prior to shipment. Upon receiving, the pump packaging
should be inspected for damages and the pump stored in a dry area.
FLUIDS ALLOWED / NOT ALLOWED
TRANSPORTATION AND HANDLING
INSTALLATION
It is recommended that the use of the pump be according to normative safety
standards and also as per the precautions listed below.
The packaging material is not in any way polluting or dangerous and does not require any
special environmental disposal precautions. Disposal should be carried out according to
local regulations in place.
PACKAGING ENVIRONMENTAL DISPOSAL
PRELIMINARY CHECKS
Check that there has been no damage to the pump during transportation or storage. Both
inlet and outlet ports should be carefully cleaned. Remove the end caps and possible dust
or residual packaging material. Verify that the available electrical power supply
corresponds to the pump specification requirements.
FIRE EXPLOSION
MOTOR OVERHEATING
FOODSTUFF LIQUID CONTAMINATION
PUMP CORROSION -
INJURY TO PERSONNEL
FIRE EXPLOSION
DAMAGE TO SEALS
FIRE EXPLOSION
POSITIONING OF THE PUMP
The pump can be mounted in any position. Fix the pump utilizing suitable diameter screws
corresponding to the holes of the flange.
MOTOR AND RUBBER IMPELLER DEMAGE
G
H
I
I-1
I-2
I-3
© S.p.A.