Troubleshooting

 

General Notes

 

  Liquids containing ferrous metal fines should not be pumped. 

  If magnets decouple, stop the pump.  Running the pump with the magnets decoupled will weaken 

the magnets. 

Lack of Flow/Head

 

  Check for air leaks in suction piping. 

  Make sure that the pump is primed and not running dry. 

  System head higher than anticipated. 

  Make sure all valves are open. 

  Viscosity or specific gravity is too high. 

  Suction lift too high or insufficient NPSH 

  System may be clogged. 

  Motor rotation incorrect. 

  Air in liquid. 

Loss of Prime

 

  Leaks in piping or air in liquid. 

  Foot valve problems. 

  Foreign objects in liquid. 

  Suction lift too high or insufficient NPSHa. 

Excessive Power Consumption

 

  Head lower than rating. 

  Too much flow. 

  Specific gravity too high. 

  Viscosity too high. 

Vibration/Noise

 

  Motor not properly secured. 

  Piping not properly secured. 

  Pump cavitation from improper suction. 

  Drive magnet rubbing against rear housing. 